Search

In Stock

PCR Rack with Cover

High-Contrast Alphanumeric Grid: Molded-in coordinate indexing facilitates error-free sample mapping and rapid identification, supporting absolute data integrity during complex multi-step amplification protocols.

Reinforced Polypropylene Architecture: Engineered for thermal resilience, this stackable system maintains mechanical stability between -90°C and +121°C, ensuring full compatibility with ultra-low temperature storage and autoclave sterilization.

$4.51

Quick Answer: A PCR rack with cover is a plastic rack with a grid of small wells for PCR tubes and tube strips, closed by a lid. The cover protects prepared reactions and reagents from dust, light and knocks while they wait in a fridge or are carried to the thermal cycler.

Why a Lid Makes a Difference

An open rack is fine while you pipette, but finished reactions often have to wait, travel down a corridor to a shared cycler or sit in a fridge overnight. The cover turns this rack into a closed box, so tubes stay put if the rack is tipped and airborne dust or droplets cannot settle on the caps.

Covers also help with light-sensitive reagents. Fluorescent probes and dyes for real-time PCR lose signal under bright bench lights, which is why some covered racks have a tinted or opaque lid. With lids closed, several racks can usually be stacked on a fridge shelf, saving space in a crowded cold room.

Most racks of this type mark positions with letters on one side and numbers on the other, copying a 96-well plate. That grid lets you draw a plate map on paper, load tubes in the same positions and transfer them to the cycler without confusing samples.

Applications

  • Holding a finished set-up in the fridge while the cycler completes another run
  • Carrying reactions from a clean set-up room to a separate amplification room
  • Shielding fluorescent qPCR reagents from bench lighting
  • Keeping amplified products in order until they are run on a gel

Specifications

Holds PCR tubes and tube strips, upright
Grid marking Alphanumeric positions, as is usual for PCR racks
Cover Lid closing over the tubes
Material Moulded plastic
Typical uses Set-up, short-term cold storage, carrying samples to the cycler

Care & Handling

  • Wipe rack and lid with a DNA-decontaminating solution between uses to stop carry-over of amplified product.
  • Keep separate racks for pre-PCR and post-PCR areas, and never bring a post-PCR rack back into the set-up room.
  • Check the plastic’s cold tolerance before freezer storage and its heat tolerance before autoclaving.
  • Close the lid gently so it does not press down on tube caps.

Why Choose LabEquip

Molecular labs that separate pre- and post-amplification areas find a covered rack the simplest way to move reactions between rooms. LabEquip offers it in the Biology Lab Products range; for an open bench rack, see the PCR tube rack. Questions about the lid can go through the contact page.

Related Products

  • PCR Tube Rack: An open PCR tube rack without a lid, quicker to load during set-up at the bench.
  • PCR Tube Strip: PCR tube strips that fill a row of this rack and suit multichannel pipetting.
  • PCR Tubes: Single PCR tubes for controls and small runs held in individual positions in the rack.
  • Rack for Micro Centrifuge Tubes: A rack for 1.5 and 2 ml microcentrifuge tubes, for reagent tubes used at the same set-up bench.

Frequently Asked Questions

What is the cover on a PCR rack for?

The lid closes over the tubes and turns the rack into a closed box. It protects prepared reactions and reagents from dust, droplets and knocks while they wait in a fridge or are carried to the thermal cycler, and keeps tubes in place if the rack is tipped.

Can PCR tubes and tube strips go in the same covered rack?

Yes. This rack holds PCR tubes and tube strips upright in the same grid. Single tubes sit in individual positions and strips of tubes fill a row, so controls in single tubes can stand next to sample strips under one lid.

Why do PCR racks have letters and numbers on the grid?

Most PCR racks mark positions with row letters and column numbers, copying a 96-well plate. You can draw a plate map on paper, load tubes in the same positions and transfer them to the cycler in that order, so samples cannot be mixed up.

Does a covered PCR rack keep reactions cold on the bench?

A plain plastic rack does not chill reactions by itself; it keeps them protected and in order. For cold set-up on the bench, stand the rack on ice or a chilled block, or set up reactions in a cooled rack, then close the lid and move the rack to the fridge.

When should I use a covered PCR rack instead of an open rack?

Use an open rack while pipetting in the set-up area, then switch to the covered rack once reactions are made: for waiting in the fridge, carrying reactions between rooms or shielding light-sensitive qPCR reagents. Many labs keep both.

How do I clean a PCR rack with cover?

Wipe the rack and lid with mild detergent or a DNA-removing wipe and let them dry. Keep acetone and other strong solvents away from the plastic. Label racks used in the clean set-up room so they are not carried into the area where PCR products are analysed.

Last Updated: November 2026

Reviews

There are no reviews yet.

Write a review

Back to Top