Quick Answer: The MCT Twin Rack is a double rack for microcentrifuge tubes (MCTs). Twin microtube racks of this kind are commonly two-faced, with one side sized for 1.5 ml and 2.0 ml tubes and the other for smaller 0.5 ml tubes, so one rack serves both tube sizes at the bench.
Two Racks in One
Molecular biology protocols often move between tube sizes: a DNA extraction in 1.5 ml tubes feeds a reaction set up in 0.5 ml tubes, or a stock is split into large and small aliquots. An MCT twin rack covers both without a second rack on the bench. With a two-faced design the rack is simply turned over to bring the other size uppermost, once the tubes on the working face have been taken out.
Twin racks are commonly moulded in polypropylene, which accepts routine disinfection and can generally be autoclaved. The Reversible Rack in the lab glassware range follows a similar two-faced idea, and the single-sided MCT Rack is the simpler option when only one tube size is used.
For teaching labs, one twin rack per pair of students can replace two single racks, which keeps stock-taking and cupboard space simpler. The trade-off is that only one face is usable at a time, so a practical that needs both sizes at once is better served by two separate racks.
Applications
- Moving from extraction in 1.5 ml tubes to reactions in 0.5 ml tubes in the same session
- Issuing one rack per student pair in molecular biology practicals
- Holding aliquots of different sizes taken from one stock solution
- Saving bench space in small labs and field kits
Specifications
| Type | Double (twin) rack for microcentrifuge tubes |
| Common arrangement | One face for 1.5 and 2.0 ml tubes, one for 0.5 ml tubes |
| How it is used | Turned over to bring the required face uppermost |
| Typical material | Polypropylene |
Care & Handling
- Empty the upper face before turning the rack over
- Clean both faces after use, since the lower face collects drips and dust
- Autoclave polypropylene racks lying flat, and let them cool before use
- Keep the rack off hot plates and out of drying ovens unless it is rated for the heat
Why Choose LabEquip
Teaching labs, diagnostic training centres and small research groups that work with two microtube sizes and want fewer racks to manage are the typical buyers. LabEquip supplies the twin rack in Biology Lab Products; tell us your tube sizes through our contact page.
Related Products
- MCT Rack: A single-size bench rack for 1.5 and 2.0 ml microtubes, for practicals that never use the smaller 0.5 ml tubes.
- Reversible Rack: A reversible two-sided microtube rack with 0.5 ml holes on one face and 1.5 or 2.0 ml holes on the other, for comparing designs.
- MCT Box: A lidded MCT storage box with a lettered and numbered grid, for keeping finished samples in the fridge or freezer.
- PCR Tube Rack: An open rack for PCR tubes and tube strips, used alongside the twin rack when reactions move into PCR tubes.
- Rack for 15/50 ml Centrifuge Tubes: Holds 15 ml and 50 ml conical centrifuge tubes upright, for the larger volumes that feed into microtube work.
Frequently Asked Questions
What is an MCT twin rack used for?
An MCT twin rack holds microcentrifuge tubes of two sizes in one rack. In its common arrangement one face takes 1.5 and 2.0 ml tubes and the other takes the narrower 0.5 ml tubes, so a DNA extraction in large tubes and a reaction set up in small tubes can share the same rack instead of needing two.
Can both faces of a two-sided tube rack hold tubes at the same time?
No. Only the face that is uppermost holds tubes upright, so the working face has to be emptied before the rack is turned over to bring the other size up. Plan the session so one tube size is finished first, or keep a second rack for the tubes that are still in use.
Why do 0.5 ml microtubes need smaller holes than 1.5 ml tubes?
A 0.5 ml tube is narrower and shorter than a 1.5 ml tube, so in a large hole it tilts, sinks too low or drops through, and its cap becomes awkward to open with one hand. The small-hole face of a twin rack grips 0.5 ml tubes at a comfortable height for pipetting and labelling.
Can a polypropylene MCT twin rack be autoclaved?
Polypropylene, the typical material for racks of this kind, generally withstands autoclaving at 121 °C. Place the rack on its own on a tray rather than under heavy items, which can warp it while hot, and let it cool fully before loading tubes so the holes keep their shape.
How do I keep samples in order when using a two-sided MCT rack?
Work along the rows in one direction, write the tube positions on a simple rack map before you start, and number both the cap and the side of each tube. Leaving an empty hole between groups of samples makes it easy to see where one set ends and the next begins.
Should I choose an MCT twin rack or a single-size MCT rack?
Choose the twin rack when your practicals use both 0.5 ml and 1.5 or 2.0 ml tubes and bench space is limited. If nearly all your work is in 1.5 ml tubes, a single-size MCT rack gives every hole to that size, and an MCT box is the better choice for storing tubes in the fridge or freezer.
Last Updated: November 2026










Reviews
There are no reviews yet.