Quick Answer: This pair of Helmholtz coils for Deflectron electron tubes produces a nearly uniform magnetic field across the tube when the same current flows through both coils. The field bends the electron beam so that its curved path can be measured, most often to find the specific charge of the electron, e/m.
Why Two Coils at a Set Spacing
A single circular coil produces a field that is strongest at its centre and falls off along its axis. In a Helmholtz pair two identical coils share a common axis and are separated by a distance equal to their radius. At that spacing the fall-off from one coil is compensated by the rise from the other, so the field in the central region is almost uniform. That uniformity matters, because the electron beam in the tube travels through a large part of the space between the coils.
The field at the centre is proportional to the coil current: B = (4/5)^(3/2) μ₀NI/R, with N turns on each coil and a coil radius R. Students measure the current with an ammeter and calculate the field, or check it with a teslameter probe, rather than relying on a nominal setting.
Using the Coils with the Deflectron
The coils sit on either side of the electron tube so that their field runs at right angles to the beam. Electrons accelerated through a potential difference V move in a circular arc of radius r, and combining eV = ½mv² with the magnetic force evB = mv²/r gives e/m = 2V/(B²r²). Raising the current makes the beam curve more tightly, which the class can watch directly on the tube’s screen.
The coils can also be combined with the tube’s own deflection plates. Adjusting the magnetic and electric fields until the beam passes straight through gives the electron speed as E/B, a crossed-field method that leads to e/m by a second route.
Experiments
- Measuring e/m from the radius of a magnetically bent electron beam
- Crossed electric and magnetic field experiments to find the electron velocity
- Showing the force on moving charges and Fleming’s left-hand rule with a visible beam
- Field-mapping practice with a teslameter probe along the coil axis
Specifications
| Product | Pair of Helmholtz coils for the Deflectron electron tube |
| Arrangement | Two identical coaxial coils spaced by their radius |
| Field | Nearly uniform in the central region, proportional to coil current |
| Main experiment | Specific charge of the electron, e/m |
| Also needed | Deflectron tube and holder, DC coil supply, ammeter |
| Number of turns, coil radius and current rating | Confirm at enquiry |
Care & Handling
- Connect the two coils so their currents circulate in the same sense; reversed coils cancel the central field
- Keep the coil current within the rating marked on the coils and do not leave them energised longer than needed
- Mount the coils firmly so their spacing cannot change between readings
- Keep hands and leads clear of the tube’s high-voltage connections when rearranging the setup
Why Choose LabEquip
The coil pair is ordered by colleges and universities that already run, or are adding, the Deflectron electron tube for e/m work. LabEquip can supply the coils together with the matching Deflectron tube holder; contact LabEquip to check compatibility with an existing tube.
Frequently Asked Questions
Why must the coils be spaced at a distance equal to their radius?
At that separation the fields from the two coils combine to be almost uniform over the central region. Closer or wider spacing makes the field vary along the axis, so the electron path would no longer be a true circle.
How is the magnetic field calculated from the current?
For a Helmholtz pair the central field is B = (4/5)^(3/2) μ₀NI/R, with N turns per coil, current I and coil radius R. The values of N and R come from the coils’ data, and the result can be checked with a teslameter.
What happens if one coil is connected the wrong way round?
The two fields then oppose each other and the field at the centre becomes nearly zero. If the beam barely bends as the current rises, check the coil connections first.
Can the Earth’s magnetic field affect the results?
Yes, slightly, because it adds to the coil field. Turning the setup so the beam runs north-south, or reversing the coil current and averaging the two readings, reduces the effect.
Are these coils suitable for other electron tubes?
They are intended for the Deflectron tube. Using them with a different tube depends on its size and mounting, so check the fit before combining equipment from different systems.
Why is a uniform field important for e/m measurement?
The formula e/m = 2V/(B²r²) assumes the same field everywhere along the electron path. A non-uniform field gives a path that is not circular, so the measured radius no longer corresponds to a single value of B.
Last Updated: October 2026










Reviews
There are no reviews yet.