Quick Answer: The pressure drop model is a fluids teaching apparatus in which water flows through a pipe circuit fitted with pressure tappings, so that the loss of pressure along pipes and across fittings can be read on manometer tubes. It is used to study friction losses in pipe flow.
Where the Pressure Goes
A real liquid loses mechanical energy to friction as it flows. Along a straight pipe of constant bore the speed does not change, so the steady fall in the manometer columns from one tapping to the next is friction loss alone. Engineers call this the major loss and describe it with the Darcy-Weisbach equation, h_f = f(L/D)(v²/2g), where f is a friction factor that depends on the flow and on the roughness of the wall.
Fittings add minor losses. Bends, elbows, valves and sudden changes of diameter disturb the flow and create eddies, and each one costs a head of K(v²/2g), where K is the fitting’s loss coefficient. In a short circuit with several fittings these so-called minor losses can easily exceed the friction along the straight pipe.
Laminar or Turbulent?
How the loss grows with flow depends on the type of flow. The Reynolds number, Re = ρvD/μ, compares inertial with viscous effects; below about 2000 pipe flow is normally laminar and the loss rises in proportion to the speed, while above about 4000 it is turbulent and the loss rises roughly with the square of the speed. Plotting the logarithm of head loss against the logarithm of flow rate gives a slope near 1 in the first case and near 2 in the second.
Flow rate is measured by timing the collection of a known volume, and the speed in each pipe follows from dividing by its cross-sectional area. The pipe sizes and fittings included in this pressure drop model are confirmed at enquiry.
Applications
- Measuring friction loss along a straight pipe at several flow rates
- Finding loss coefficients for bends, contractions or valves
- Identifying laminar and turbulent flow from a log-log plot
- Discussing energy losses in water mains and heating circuits
Specifications
| Product | Teaching model for pressure (head) loss in pipe flow |
| Measured quantity | Pressure difference between tappings, read as a head of water |
| Losses studied | Friction along straight pipe and losses at fittings |
| Key relations | h_f = f(L/D)(v²/2g); h = K(v²/2g); Re = ρvD/μ |
| Pipe sizes, fittings and water supply | Confirm at enquiry |
Care & Handling
- Bleed all air from the pipes and manometer tubes before taking readings
- Use clean water, with a little colouring in the manometer tubes for visibility
- Drain the circuit completely after use to prevent algae and scale
- Change the flow gently so the manometer columns do not overflow
Why Choose LabEquip
Engineering colleges and senior physics classes need a rig on which pipe friction is measured rather than just described, and the pressure drop model gives readings students can analyse. For a separate set of pipes to compare lengths and bores, see the pipes for pressure drop experiments; contact LabEquip to confirm the layout, or browse more physics lab equipment.
Frequently Asked Questions
What is the difference between major and minor losses?
Major losses come from friction along straight lengths of pipe and grow with length. Minor losses occur at fittings such as bends, valves and changes of diameter, where the flow is disturbed; in a short circuit they can be larger than the straight-pipe loss.
Why does doubling the flow rate roughly quadruple the pressure drop?
In turbulent flow the loss is close to proportional to the square of the velocity. In slow laminar flow the loss is proportional to velocity instead, so doubling the flow only doubles it.
How is the flow rate measured?
Usually by timing how long the outflow takes to fill a measuring cylinder or a weighed container and dividing volume by time. The velocity in a pipe is then the flow rate divided by the pipe’s cross-sectional area.
What does the Reynolds number tell us?
It compares inertial and viscous effects in the flow. Below about 2000 pipe flow is normally laminar and smooth, above about 4000 it is turbulent, and between the two it can switch either way.
Why must air be removed from the tappings?
Bubbles in a tapping line or manometer tube add their own small pressure differences and make the columns jump. Bleeding them out before each run gives steady, comparable readings.
Which fittings does the model include?
The pipe sizes and fittings can be confirmed at enquiry. Whatever the layout, the method is the same: read the head on either side of each element and divide the loss by v²/2g to find its coefficient.
Last Updated: October 2026










Reviews
There are no reviews yet.