Search

In Stock

Kipps Gas Generating Apparatus, Clear Glass

Hydrostatic Pressure Regulation: Features a three-tier interlocked geometry that utilizes gravity-fed liquid displacement to automate gas generation upon stopcock opening and immediate cessation upon closure.

High-Clarity Optical Grade Glass: Fabricated with uniform wall thickness and high-transparency clear glass, allowing for unobstructed visual monitoring of reagent consumption and precipitate formation during volatile chemical synthesis.

₹605.00

Quick Answer: The Kipps gas generating apparatus in clear glass is a three-bulb gas generator that delivers carbon dioxide, hydrogen or hydrogen sulfide on demand from a solid and a dilute acid. It suits school and college practicals where a steady stream of gas is needed at the turn of a tap.

Charging the Apparatus for a Practical

Preparing the generator follows a fixed order. The middle globe is filled through its side opening with lumps of the solid, for example marble chips for carbon dioxide, and the opening is closed with its stopper or outlet fitting. With the tap open, dilute acid is poured into the top reservoir; it runs down the central tube, fills the lowest globe and rises into the middle one until it reaches the solid. Gas production begins at once, and the first gas out, mixed with air, is allowed to escape before collection starts.

From then on, the tap is the only control. Opening it lets gas flow to a delivery tube, gas jar or test tube; closing it pushes the acid away from the solid and production stops. At the end of the session, the spent acid is run off through the outlet near the base, the solid is rinsed and removed, and the globes are washed.

The title names clear glass without giving the composition, which in catalogue terms usually means soda-lime rather than borosilicate. Because the apparatus is never heated, that difference mainly affects durability. The borosilicate glass version is the sturdier option for heavy use, and a gas jar with ground flange is the usual vessel for collecting the gas.

Specifications

Item Three-globe gas generator with outlet tap
Material Clear glass, type unspecified
Reaction type Solid lumps with dilute acid at room temperature
Control Outlet tap; closing it separates acid from solid

Applications

  • Filling gas jars with carbon dioxide to show that it is denser than air and puts out a burning splint
  • Bubbling carbon dioxide through limewater to show the milky calcium carbonate precipitate
  • Collecting hydrogen over water for density and burning tests, discarding the first portions
  • Supplying hydrogen sulfide for salt analysis at senior secondary level, in a fume cupboard

Care & Handling

  • Use dilute acid only and keep the tap closed while the apparatus stands charged.
  • Stand the generator on a flat, stable bench, since the charged apparatus is heavy and top-heavy.
  • Replace the solid when gas flow stays weak even with fresh acid, as the lumps become coated with reaction products.
  • Keep flames away from the outlet while hydrogen is being produced.

Why Choose LabEquip

Schools and junior colleges that prepare gases in front of a class or for group work often choose a clear glass Kipps gas generating apparatus as the everyday option. It is part of the LabEquip chemistry lab equipment range; ask about class-set quantities through the contact page.

Related Products

Frequently Asked Questions

How do you charge a clear glass Kipps apparatus for a practical?

Fill the middle globe through its side opening with lumps of solid, such as marble chips for carbon dioxide, and close the opening with its stopper or outlet fitting. With the tap open, pour dilute acid into the top reservoir until it rises into the middle globe and touches the solid. Gas production then starts at once.

Why should the first gas from a Kipps generator be discarded?

The middle globe starts full of air, so the first gas out is a mixture of air and product. Letting it escape for a short time before collecting gives a purer sample. With hydrogen this is a safety step as well, because a hydrogen and air mixture can explode if ignited.

Which acid is used to make carbon dioxide in a Kipps apparatus?

Dilute hydrochloric acid with marble chips is the usual choice. Sulfuric acid is avoided, because it forms insoluble calcium sulfate that coats the marble and stops the reaction. The carbon dioxide can be bubbled through limewater, which turns milky, to confirm the gas.

Why has the gas flow from my Kipps apparatus become slow?

Either the acid is nearly used up, or the solid has worn down to small pieces with little surface left. Run off the spent acid through the bottom outlet and add fresh acid, and top up the middle globe with new lumps. A coating on the solid can also slow the reaction.

Is a clear glass Kipps generator suitable for hydrogen sulfide?

The glass itself copes with the acids used, but hydrogen sulfide is toxic, so the generator must sit in a fume cupboard with the gas led only to the test solutions there. Many schools now choose other demonstrations instead; carbon dioxide and hydrogen are the usual class gases.

How should a Kipps apparatus be stored between practicals?

Empty the spent acid through the bottom outlet, rinse all three globes with water, and remove leftover solid. Let it dry with the tap open and stoppers loosened, so nothing seizes. Store it upright in a stable position where the heavy globes cannot be knocked over.

Last Updated: November 2026

Reviews

There are no reviews yet.

Write a review