Search

In Stock

Oscillator A.F./R.F.

Combined AF and RF output ranges with calibrated frequency control for broad experimental coverage

Low-distortion sine wave generation with stable amplitude, ensuring repeatable laboratory results

₹3,521.00

Quick Answer: This A.F./R.F. oscillator is a bench signal generator that produces alternating voltages at audio frequencies (A.F.) and at radio frequencies (R.F.). It is the signal source for resonance, filter, wave and modulation experiments in college physics and electronics laboratories.

What the Oscillator Does

An oscillator is an amplifier with feedback arranged so that it sustains its own oscillation at a frequency set by its tuning network, a resistor-capacitor network in many audio designs and an inductor-capacitor tank circuit at radio frequencies. The front panel selects the band and sets the frequency within it, and an amplitude control or attenuator sets how large the output signal is. Most instruments of this type give a sine wave, and many add a square wave; the waveforms, frequency bands and output levels of this model should be confirmed before ordering.

Audio frequencies are the ones the ear can hear, roughly from tens of hertz to around twenty kilohertz, so the A.F. section can drive a loudspeaker or a vibrator for sound and wave experiments. Radio frequencies lie above that and are used for tuned circuits, transmitter and receiver principles, and amplitude modulation.

Getting Clean Results

Start every experiment with the output turned down and increase it only as far as needed; large signals distort and can overload the circuit under test. Watch the output on a cathode ray oscilloscope to confirm the waveform and frequency rather than relying on dial markings alone. At radio frequencies, keep leads short, use screened cable and connect all earths to one common point, since long loose wires pick up and radiate signals. Many generators are designed to drive a defined load, often 50 ohms; terminating the output with a matching fixed 50 ohm resistor keeps the amplitude steady as the frequency is varied.

Experiments Using the Oscillator

  • Series and parallel LCR resonance and the Q factor of a circuit
  • Frequency response of RC and LC filters
  • Comparing frequencies with Lissajous figures on an oscilloscope
  • Driving a loudspeaker for resonance-tube and standing-wave experiments, or an electromagnet for sonometer work
  • Amplitude modulation and demodulation using the R.F. output as carrier

Specifications

Type Signal generator with audio-frequency and radio-frequency bands
Controls Band selection, frequency tuning, output amplitude
Usual waveform Sine wave, often with square wave
Monitored with Cathode ray or digital oscilloscope
Frequency bands, waveforms and output level Confirm at enquiry

Care & Handling

  • Switch on and let the oscillator settle for a few minutes before taking frequency-sensitive readings.
  • Never connect the output to a supply or to another source; it can damage the output stage.
  • Keep ventilation openings clear and the instrument away from damp.
  • Check the mains cable and output leads before use, and leave internal servicing to qualified technicians.

Why Choose LabEquip

Degree and diploma colleges buy audio and radio frequency oscillators for their electronics and wave practicals, usually one per oscilloscope bench. LabEquip lists this instrument among its physics equipment, and the frequency coverage a syllabus needs can be checked through the contact page before ordering.

Frequently Asked Questions

What is the difference between A.F. and R.F. output?

A.F. covers audio frequencies, the range the ear can hear, used for sound, wave and filter experiments. R.F. covers higher radio frequencies, used for tuned circuits and modulation.

How is LCR resonance found with the oscillator?

Connect the oscillator to the LCR circuit, keep the output amplitude constant and vary the frequency while measuring the current or the voltage across the resistor. The frequency giving the peak response is the resonant frequency.

Why should the output be checked on an oscilloscope?

The oscilloscope shows the actual waveform, amplitude and period, revealing distortion or loading that dial settings cannot. Frequency can be calculated from the measured period.

What are Lissajous figures used for?

When two signals drive the X and Y inputs of an oscilloscope, the pattern formed shows the ratio of their frequencies and their phase difference. It is a classic way to compare an unknown frequency with the oscillator.

Why does the output fall when a circuit is connected?

The oscillator has internal output resistance, so a low-resistance load takes more current and the voltage at the terminals drops. Measure the signal at the circuit and adjust the amplitude if necessary.

Is the R.F. output safe to handle?

The output levels of a laboratory oscillator are low, but switch off before changing connections and keep the mains side of the instrument closed. Use screened leads at radio frequency to limit interference.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top