Search

In Stock

Maxwell Vibration Needle

Symmetrical Modular Mass Set: Comprises a precision-machined hollow brass tube equipped with two solid and two hollow cylinders of identical length, ensuring high-fidelity moment of inertia transitions during experimental cycles.

Axial Torsion Head Assembly: Features a heavy-duty, adjustable mounting chuck designed to eliminate wire slippage and maintain perfect vertical alignment, minimizing parasitic mechanical damping for accurate period-of-oscillation data acquisition.

₹845.00

Quick Answer: The Maxwell Vibration Needle is a hollow tube hung horizontally from the wire under test and loaded with two solid and two hollow cylinders that can be swapped between the inner and outer positions. Timing the torsional oscillations in both arrangements gives the modulus of rigidity of the wire, without needing the moment of inertia of the tube itself.

How Maxwell’s Needle Removes the Unknown

A body twisting on a wire oscillates with period T = 2π√(I/C), where C = πηr⁴/2l depends on the modulus of rigidity η, the radius r and the length l of the wire. To find η, the moment of inertia I of the hanging body must be known, and for a tube with clamps, end caps and a central fitting that is hard to calculate.

Maxwell’s vibration needle avoids the problem by changing I by a known amount instead of finding it outright. The tube is divided into four equal compartments. In the first arrangement the two solid cylinders sit in the outer compartments and the hollow ones in the inner; in the second they change places. Everything else stays the same, so the difference in moment of inertia depends only on the difference in mass between solid and hollow cylinders, ms − mh, and the length L of the tube: ΔI = (ms − mh)L²/4.

With T1 and T2 the periods in the two arrangements, η = 2πlL²(ms − mh)/(r⁴(T1² − T2²)). Since the wire radius enters to the fourth power, it is measured with a micrometer screw gauge at several points along the wire and the mean is used. Oscillations are counted against a fixed mark or pointer placed just below the needle.

Experiments

  • Determining the modulus of rigidity of a steel, brass or copper wire by the dynamic method
  • Comparing the rigidity of wires of different metals hung in turn from the same support
  • Showing how changing the mass distribution changes the period without changing the total mass
  • Practising precise timing and the micrometer measurement of a fine wire radius

Specifications

Instrument Maxwell’s vibration needle: hollow tube with four interchangeable cylinders
Cylinders Two solid and two hollow, of equal length
Method Torsional oscillation in two arrangements, periods T1 and T2
Result Modulus of rigidity η of the suspension wire
Wire material, tube length and support Confirm at enquiry

Care & Handling

  • Handle the cylinders of the Maxwell vibration needle by their ends and keep matched pairs together; mixing them with another set breaks the equal-mass pairing.
  • Hang the needle horizontal before timing, and let it come to rest so that it twists without swinging.
  • Remove the needle from the wire after the practical, so the wire does not stay under load and creep.
  • Store the cylinders dry, and lightly oiled if they are steel, to prevent rust adding mass.

Why Choose LabEquip

Degree-level physics laboratories run Maxwell’s needle as a standard dynamic method for rigidity, and it compares well with the Searle’s rigidity apparatus, which uses two bars. LabEquip lists both in its physics equipment category. Use the contact page to discuss quantities and wires.

Frequently Asked Questions

Why are solid and hollow cylinders used?

They have the same length and outer size but different masses. Swapping them between the outer and inner compartments changes the moment of inertia of the needle by a known amount, while leaving the suspension, total mass and wire unchanged.

Why is the radius of the wire so important?

The rigidity calculation uses the fourth power of the radius. A 1 percent error in the radius therefore becomes a 4 percent error in the result, so the radius should be measured with a micrometer screw gauge at many points and averaged.

Should the needle swing or twist?

Only twist. Turn the needle gently through a small angle about the wire and release it. If it also swings like a pendulum, stop it and start again, because sideways swinging disturbs the period.

Why time many oscillations rather than one?

A single period may last only a few seconds, so reaction time is a large fraction of it. Timing twenty or more oscillations and dividing spreads that error over the whole run. Repeat each arrangement and use the mean period.

How does Maxwell’s needle differ from a torsion pendulum?

Both use a body twisting on a wire. A torsion pendulum needs the moment of inertia of its disc to be calculated. Maxwell’s needle only needs the change in moment of inertia between two arrangements, which comes from the cylinder masses and the tube length.

Does the length of wire matter?

Yes. The restoring couple is inversely proportional to the length l between the clamp and the needle, so l is measured carefully from the bottom of the upper clamp to the top of the needle’s fitting. Longer wires give slower oscillations that are easier to time.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)