Search

In Stock

Torsion Apparatus Searle’s Type

Dual Graduated Wheel System: Features two large-diameter, precision-machined metallic wheels equipped with 360-degree circular scales and vernier readers to facilitate high-resolution angular displacement measurements during experimental cycles.

Reinforced Structural Frame: Constructed with a heavy-gauge cast iron base and high-tolerance chucks to ensure slip-free clamping of specimen wires, minimizing mechanical drift and ensuring consistent axial alignment under maximum load.

₹1,524.00

Quick Answer: The Torsion Apparatus Searle’s Type finds the modulus of rigidity of a rod or thick wire by the static method: one end is clamped, the other is twisted by a weight acting on a cord around a wheel, and two pointers read the angle of twist over circular scales. The Searle’s type torsion apparatus is usually built in a horizontal pattern on a bench base.

Measuring Rigidity by Twisting a Rod

In the static method, a known couple is applied to a specimen and the twist it produces is measured directly, rather than inferred from oscillations. In the Searle’s type arrangement the specimen lies along the base with one end held in a fixed clamp. The other end is fixed to the axle of a wheel or drum that turns in a bearing, and a cord wound round the drum runs to a weight hanger. Adding a mass M to the hanger applies a couple MgR, where R is the radius of the drum plus half the cord thickness.

Two pointers are clamped to the rod a measured distance l apart, each moving over its own circular scale. Reading the difference between their deflections, rather than the deflection of the free end alone, means that any slip at the fixed clamp or twist in the fittings does not enter the result. The twist θ over length l, converted to radians, then gives η = 2MgRl/(πr⁴θ), where r is the radius of the rod.

Loads are added in equal steps and the twist recorded at each, then removed in the same steps. A graph of θ against M should be a straight line through the origin, and its gradient gives the most reliable value of η. If the unloading readings fail to return to zero, the specimen has been twisted beyond its elastic limit and lighter loads should be used.

Experiments

  • Determining the modulus of rigidity of steel, brass or aluminium rods by the static method
  • Verifying that the angle of twist is proportional to the applied couple
  • Comparing the results with a dynamic method such as the torsion pendulum or Maxwell’s needle
  • Showing how the twist grows with the distance between pointers along the specimen

Specifications

Method Static torsion: known couple, measured angle of twist
Layout Specimen clamped at one end; other end turned by a cord, drum and weight hanger
Readings Two pointers over circular scales, a measured distance apart
Result η = 2MgRl/(πr⁴θ), from the gradient of twist against load
Specimen rods, scales and weights supplied Confirm at enquiry

Care & Handling

  • Tighten both clamps of the Searle’s type torsion apparatus fully, without crushing the rod, before any load is applied.
  • Add and remove weights gently; a dropped mass jerks the specimen and can twist it past its elastic limit.
  • Keep the drum bearing clean and lightly oiled so that friction does not absorb part of the applied couple.
  • Store specimen rods straight and labelled by material, since a bent rod twists unevenly.

Why Choose LabEquip

College physics laboratories use the Searle’s type apparatus to teach the static rigidity method alongside dynamic methods. Barton’s vertical pattern applies the couple through two pulleys instead of one cord, and LabEquip lists both with its physics lab equipment. Request details through the contact page.

Frequently Asked Questions

Why are two pointers used instead of one?

With one pointer at the free end, any slip at the fixed clamp would be counted as twist. Two pointers clamped to the rod measure the twist over the length between them only, so clamp slip and play in the fittings cancel.

How is the couple calculated?

The couple is the hanging weight multiplied by the radius at which the cord pulls, MgR. Measure the drum diameter with vernier calipers, add the cord thickness and halve the total to get R.

Why must the angle be converted to radians?

The torsion formula is derived with the angle in radians. Multiply a reading in degrees by π/180 before substituting it, or the modulus of rigidity will be wrong by a factor of about 57.

How do I know the rod has not been overloaded?

Unload in the same steps used for loading. If the pointers return to their original readings, the twist was elastic. If they stay displaced, the rod has taken a permanent set, and smaller loads must be used.

What is the difference between the static and dynamic methods?

The static method applies a known couple and measures the steady twist it causes. Dynamic methods, such as the torsion pendulum, time the oscillations of a body on the wire. Comparing both on the same material is a good check on systematic errors.

Can the apparatus test different metals?

Yes, if specimen rods of other metals fit the clamps. Each rod is tested in turn with the same drum and scales, and comparing the gradients shows directly which metal is stiffer in shear.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency