Electroscope à aiguille Features a low-friction, gravity-compensated aluminum pointer mounted on a high-sensitivity pivot, enabling calibrated deflection for the quantitative assessment of electrostatic potential difference (V) with minimal mechanical resistance.

Shielded Dielectric Housing Constructed with a transparent, EMI-shielded metal enclosure and high-resistance PTFE (Polytetrafluoroethylene) insulation, preventing external environmental interference and accidental charge leakage for repeatable data acquisition in variable humidity conditions.

₹1,246.00

Quick Answer: The Needle Electroscope is an electrostatic detector in which a light metal needle, pivoted beside a fixed vertical conductor, swings away from it when charge reaches the terminal on top. As pictured, the needle sits inside a transparent case that keeps out draughts, on a stand.

Pointer Versus Leaf

In a gold leaf electroscope a thin leaf hangs from a rod and lifts when both carry the same charge. This instrument replaces the leaf with a balanced metal needle on a pivot, so the moving part is far less fragile. The trade-off is sensitivity: the needle has more mass and some pivot friction, so it needs a larger charge or potential to move noticeably, but it survives student handling and can be left set up between lessons.

Because the needle turns about a fixed axis, its deflection angle is easy to judge, and with a scale placed behind the case it can be compared from one test to the next. That makes the instrument useful as a rough electrostatic voltmeter, showing whether a potential rises or falls during an experiment.

Using the Pointer Instrument with a Capacitor

One of the clearest uses is with a parallel-plate capacitor. Connect one plate to the top terminal, earth the other plate and the case, charge the plates and remove the source. As the plates are pulled apart the needle deflects further, even though no charge has been added. With the charge fixed, a rising potential shows that the capacitance has fallen, in line with C = Q/V and with capacitance decreasing as plate separation increases. Sliding an insulating sheet between the plates does the opposite and lowers the deflection.

Applications

  • Detecting charge on rubbed rods and on objects charged by a generator
  • Comparing charging by contact and by induction in student practical work
  • Showing how potential changes with plate separation and dielectric in a parallel-plate capacitor
  • Checking that an apparatus has been discharged before it is handled

Specifications

Type Needle (pointer) electroscope
Indicator Pivoted metal needle beside a fixed conductor
Housing Transparent case on a stand, as pictured
Input Terminal on top for contact charging or a lead from a source
Case size, insulator material and scale Confirm at enquiry

Care & Handling

  • Carry the instrument upright and gently; a sharp knock can unseat the needle from its pivot.
  • Wipe the case and the insulator around the terminal with a dry cloth; never use a damp cloth just before a lesson.
  • Discharge the terminal with a finger before changing the experiment.
  • Store it covered in a dry cupboard so dust does not settle on the pivot.

Why Choose LabEquip

Schools buy a needle model for student groups because it tolerates handling better than a leaf instrument, while a delicate gold leaf electroscope is often kept for teacher demonstrations. For capacitor work, pair it with the Aepinus condenser; more items are listed in the LabEquip Physics Equipments category.

Frequently Asked Questions

Is a needle electroscope as sensitive as a gold leaf electroscope?

No. The needle is heavier than a gold leaf and turns on a pivot with some friction, so it needs a larger charge to move. In return it is much more robust, which suits student practicals and repeated use.

Why does the needle deflect for both positive and negative charge?

The needle and the fixed conductor always receive charge of the same sign from the terminal, and like charges repel whatever their sign. To find the sign of a charge, first give the instrument a known charge and see whether the object increases or reduces the deflection.

Why should the case be earthed?

Earthing the case gives a fixed reference, so the deflection depends on the potential of the terminal relative to earth. It also stops charge collecting on the case and pulling the needle unpredictably.

What does it mean if the needle falls back quickly?

The charge is leaking away, usually because the insulator or the air is damp or dusty. Dry the instrument in a warm room, clean the insulator, and test again.

Can the pointer instrument measure voltage?

Only roughly. The deflection rises with the potential of the terminal, so it shows whether a potential is increasing or decreasing, but it is not calibrated like a voltmeter and draws no steady current.

How do I charge it by induction?

Hold a charged rod near the terminal without touching, touch the terminal briefly with a finger to earth it, take the finger away, then remove the rod. The needle stays deflected with a charge opposite in sign to the rod.