Search

In Stock

Magnetometer Deflection

Anti-Parallax Compass Assembly: Features a high-sensitivity magnetized needle balanced on a low-friction pivot, integrated with a circular mirrored scale to eliminate observational errors during 0–90 degree angular deflection measurements.

Non-Magnetic Metric Bench: Constructed from stabilized, non-ferrous materials, the one-meter base includes dual-engraved linear scales for the precise longitudinal positioning of specimen magnets in Tan-A and Tan-B orientations.

$8.51

Quick Answer: The Magnetometer Deflection is a deflection magnetometer: a compass box with a short pivoted needle, a long pointer over a circular scale and two long arms graduated as scales. A bar magnet placed on an arm deflects the needle, and the angle of deflection is used to compare magnetic moments and to verify the tangent law.

How the Deflection Magnetometer Works

With no magnet nearby, the needle lies along the Earth’s horizontal field. A bar magnet placed on one of the arms adds a second field at right angles to it, and the needle settles along the resultant. By the tangent law, the magnet’s field at the needle equals the Earth’s horizontal field times the tangent of the deflection. A light aluminium pointer fixed across the short needle magnifies the reading on the circular scale, and a plane mirror under the pointer removes parallax: the reading is taken when the pointer hides its own image.

The two arms carry scales measured from the centre of the needle, so the distance of the magnet’s centre can be set directly. The arrangement allows the magnet to be placed in the two standard positions used in practical work.

Tan A and Tan B Positions

In the Tan A, or end-on, position the arms lie along the magnetic east-west line and the magnet is placed along the arm with its axis pointing at the needle. In the Tan B, or broadside-on, position the arms lie north-south and the magnet lies across the arm, so the needle is on its equatorial line. Different formulas link the deflection to the magnetic moment in each position.

Good practice is to take four readings at each distance: both ends of the pointer, then again with the magnet reversed, and repeat with the magnet on the other arm at the same distance. Averaging these cancels errors from an off-centre pivot and from the magnetic poles not lying at the ends of the magnet.

Practicals Using the Magnetometer

  • Verifying the tangent law of magnetism
  • Comparing the magnetic moments of two bar magnets by the equal-distance and null methods
  • Finding the ratio M/BH, the magnetic moment divided by the Earth’s horizontal field
  • Determining BH together with a vibration magnetometer

Specifications

Type Deflection magnetometer
Needle and reading Short magnetic needle with a long pointer over a circular scale
Parallax control Mirror beneath the pointer (usual design)
Arms Two long graduated arms for setting magnet distance
Scale divisions and arm length Confirm at enquiry

Care & Handling

  • Set up on a wooden table well away from steel, power cables and other magnets.
  • Lock or steady the needle before moving the instrument so the pivot is not jarred.
  • Keep the mirror and glass clean, and handle the arms by their ends so they stay straight.
  • Store test magnets in pairs with keepers, away from the magnetometer box.

Why Choose LabEquip

Senior-school and college physics departments buy deflection magnetometers for the magnetism practicals in their syllabus, usually alongside a vibration magnetometer and paired bar magnets. LabEquip lists them in its physics equipment category, and the number needed for a practical batch can be discussed through the contact page.

Frequently Asked Questions

What is the tangent law used with a deflection magnetometer?

When two fields act at right angles on a freely pivoted needle, it settles so that the tangent of its deflection equals the ratio of the two fields. The magnet field at the needle therefore equals the horizontal field of the Earth times the tangent of the deflection.

What is the difference between the Tan A and Tan B positions?

In Tan A the needle lies on the axis of the magnet, with the arms along the east-west line. In Tan B the needle lies on the perpendicular bisector of the magnet, with the arms along the north-south line. Each position has its own formula.

Why are four readings taken at each distance?

Reading both ends of the pointer cancels error from a pivot that is not exactly central. Reversing the magnet and moving it to the other arm cancels errors from the poles not being symmetrical about the centre of the magnet.

Why is there a mirror under the pointer?

The mirror shows a reflection of the pointer. Reading the scale with the eye placed so that the pointer hides its image puts the line of sight vertically above the pointer, which removes parallax error.

How are the magnetic moments of two magnets compared?

In the equal-distance method each magnet is placed at the same distance and their moments are in the ratio of the tangents of their deflections. In the null method the magnets are placed on opposite arms and moved until the needle returns to zero.

Why should the deflection be kept between about 30 and 60 degrees?

The error in the tangent of an angle caused by a small reading error is smallest near 45 degrees. Very small or very large deflections make the calculated field much more sensitive to slight misreadings.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top