Search

In Stock

Hall Effect in n and p Doped Germanium (teslameter)

TP Effet Hall dans du germanium dopé n et p (teslametre), Integrated High-Precision Teslameter Enables the Evaluation of magnetic flux density influence on carrier deflection, supporting rigorous data acquisition for Advanced Electromagnetism modules.

Linear Sample Current Control Supports the Application of Lorentz force principles in calculating carrier concentration and mobility indices through variable current density.

Temperature Monitoring Interface Allows students to Synthesize data regarding the thermal dependency of semiconductor conductivity and the transition from extrinsic to intrinsic conduction.

₹68,754.00

Quick Answer: The Hall effect in n and p doped germanium experiment measures the small voltage that appears across a current-carrying germanium sample in a magnetic field. With the field measured on a teslameter, students find whether the charge carriers are electrons or holes, how many there are and how mobile they are.

How the Hall Voltage Arises

When a current flows along a flat semiconductor sample in a magnetic field perpendicular to it, the moving charge carriers are pushed sideways by the magnetic force. They build up on one edge until the resulting electric field balances the magnetic force, and a voltage, the Hall voltage, appears across the sample’s width. Its size is U_H = IB/(nqt), where n is the carrier density, q the carrier charge and t the sample thickness.

The sign of the Hall voltage reveals the sign of the carriers. In n-doped germanium the current is carried mainly by electrons, while in p-doped germanium it is carried by holes, which behave as positive charges. With the same current direction and field, the two samples give Hall voltages of opposite polarity, direct evidence that holes are real carriers rather than a book-keeping device.

From Measurements to Material Properties

The teslameter measures the field between the magnet poles at the sample position for each coil current. Plotting the Hall voltage against field at constant current, or against current at constant field, gives straight lines whose gradient yields the Hall coefficient R_H = 1/(nq) and so the carrier density. Measuring the sample’s ordinary resistance along its length gives the conductivity, and multiplying conductivity by the Hall coefficient gives the carrier mobility.

Many setups of this type also allow the sample to be heated. As the temperature rises, electrons are excited across the band gap and the semiconductor moves from extrinsic to intrinsic conduction, which can even reverse the sign of the Hall voltage in the p-type sample. Whether this module includes heating should be confirmed before planning that extension.

Specifications

Experiment Hall effect in n-type and p-type doped germanium
Field measurement Teslameter, as listed in the product name
Results Carrier type, carrier density, Hall coefficient and mobility
Key relations U_H = IB/(nqt) and R_H = 1/(nq)
Sample boards, magnet, supplies and heating option Confirm at enquiry

Practical Uses

  • Undergraduate solid-state physics practicals on semiconductors
  • Showing that holes behave as positive charge carriers
  • Determining carrier density and mobility in doped germanium
  • Calibrating a magnetic field against coil current with a teslameter

Care & Handling

  • Keep the sample current within the value stated for the sample boards; germanium heats quickly and its properties change with temperature
  • Handle sample boards by their edges and avoid touching the germanium crystal or its contacts
  • Remove the teslameter probe from the pole gap before moving the magnet, as Hall probes are delicate
  • Zero the Hall voltage reading with the field off to remove the offset from misaligned contacts

Why Choose LabEquip

The Hall effect in germanium is a staple of second- and third-year physics laboratories, and departments usually want both the n-type and p-type samples so that the sign reversal can be shown side by side. LabEquip supplies it alongside other modern physics experiments such as the semiconductor thermogenerator; contact LabEquip to confirm the components.

Frequently Asked Questions

Why does the Hall voltage have opposite signs for n- and p-type germanium?

In n-type germanium the carriers are negative electrons and in p-type germanium they are positive holes. The magnetic force pushes both towards the same edge for a given current, so the charge that collects there, and the voltage, has opposite signs.

What is the teslameter used for?

It measures the magnetic flux density at the sample. The Hall coefficient is calculated from the Hall voltage, current and field, so an accurate field value is essential.

Why is there a voltage even when the field is zero?

The Hall contacts are never perfectly opposite each other, so part of the ordinary voltage drop along the sample appears between them. This offset is measured with the field off and subtracted, or removed by reversing the field and averaging.

How is the carrier mobility found?

Measure the conductivity of the sample from its resistance and dimensions, then multiply it by the Hall coefficient. The product gives the mobility of the majority carriers.

Why is germanium used instead of a metal?

Metals have so many free electrons that their Hall voltage is tiny. A doped semiconductor has far fewer carriers, so the Hall voltage is much larger and easy to measure.

What happens to the Hall voltage when the sample is heated?

Heating generates electron-hole pairs across the band gap. At high enough temperature intrinsic conduction dominates, the Hall voltage falls, and in p-type germanium it can change sign because electrons are more mobile than holes.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)