Search

In Stock

Ball for Free Fall

Bille pour chute libre Minimizes aerodynamic drag coefficients and surface oxidation, supporting student Analysis of vacuum-approximation models and kinematics in Advanced Mechanics Module 101.

Precision G100 Sphericity ensures consistent center-of-gravity alignment during descent, allowing for the technical Application of evidentiary-grade data acquisition in high-cadence undergraduate research rotations.

Impact-Resistant Metallurgy Maintains structural and dimensional integrity across repeated landing cycles, ensuring long-term experimental Consistency and reducing laboratory replacement frequency.

₹175.00

Quick Answer: A ball for free fall is the dense ball dropped in free-fall apparatus to measure the acceleration due to gravity, g. It is held at the top, usually by an electromagnet, released at the same instant a timer starts, and timed until it reaches a detector a measured distance below.

Timing a Fall

A body falling from rest covers a height h = ½gt² in time t, so a single drop gives g = 2h/t². A one-metre drop takes about 0.45 s, far too short to time by hand, which is why free-fall apparatus uses an electronic timer started by the release and stopped by a pad, light gate or impact sensor at the bottom. A small, dense ball is chosen because air resistance on it is tiny compared with its weight over a fall of a metre or two.

Holding the ball with an electromagnet gives a clean start: switching off the current releases the ball and starts the timer through the same switch. For this the ball must be ferromagnetic, which is why a steel ball for free fall is the usual choice.

Removing the Release Delay

An electromagnet does not let go instantly. The field takes a moment to collapse and some magnetism remains, so the ball leaves a few milliseconds after the timer starts and every measured time is slightly too long. A graph separates this constant error from g. Since the measured time is t = √(2/g) × √h + δ, where δ is the delay, timing five or six heights and plotting t against √h gives a straight line. Its gradient is √(2/g), so g equals 2 divided by the gradient squared, and the intercept on the time axis is the delay itself. Using the smallest magnet current that still holds the ball also shortens the delay.

Practical Work

  • Measuring g with an electromagnet release and electronic timer
  • Plotting t against √h so that a release delay shows up as the intercept
  • Comparing balls of different mass to show that they fall at the same rate
  • Triggering a high-speed or video recording at the moment of release

Specifications

Item Ball for free-fall experiments
Usual release method Electromagnet, which needs a ferromagnetic (steel) ball
Measurement Fall time t over a measured height h
Governing relation h = ½gt², so g = 2h/t²
Diameter and mass Confirm at enquiry

Care & Handling

  • Catch the ball on a soft pad or in a sand tray so it does not bounce away or dent the bench.
  • Keep the ball and the electromagnet face clean and dry; dirt between them weakens the hold.
  • Wipe a steel ball lightly with an oiled cloth before storage to prevent rust spots.
  • Measure the drop height from the bottom of the ball at release to the detector surface.

Why Choose LabEquip

Schools and colleges buy spare free-fall balls because they roll away and get lost, and because a set allows several groups to run the practical at once. LabEquip lists this ball in its physics lab equipment range with a shock detector for stopping the timer and a light barrier as an alternative detector. Diameter and quantity can be confirmed through the contact page.

Frequently Asked Questions

Why is a steel ball used for free-fall timing?

Most free-fall apparatus holds the ball with an electromagnet, which only works on a ferromagnetic material such as steel. Steel is also dense, so air resistance is very small compared with the ball’s weight.

Why does the electromagnet make the measured time too long?

When the current is switched off, the magnetic field takes a moment to collapse and a little magnetism remains, so the ball leaves slightly after the timer starts. The delay is roughly the same on every drop.

How do I find g from several drop heights?

Plot the fall time t against the square root of the height for five or six heights. The gradient equals √(2/g), so g is 2 divided by the gradient squared, and a constant release delay appears as the intercept instead of spoiling the gradient.

Does air resistance affect the result?

For a small, dense ball falling a metre or two, air resistance is a tiny fraction of the weight and its effect is smaller than typical timing errors. Light or large balls would be affected much more.

What stops the timer at the bottom?

Usually a contact pad, a trap door, an impact sensor or a light gate. Each detects the arrival of the ball and sends a stop signal to the electronic timer.

Why should the ball land on a soft pad?

A steel ball dropped onto a hard bench bounces unpredictably, can dent the surface and may roll off and be lost. A pad or sand tray stops it where it lands.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)