Search

In Stock

Babinet Compensator

Precision Wedge Plates: Adjustable compensator plates allow fine-tuning of optical path differences for high-accuracy measurements.

Robust Optical Construction: Crafted from durable, anti-reflective-coated glass to ensure consistent performance and longevity in laboratory settings.

$18.27

Quick Answer: The Babinet Compensator is an optical instrument made of two thin wedges of crystalline quartz with their optic axes at right angles, one wedge moved by a screw. Placed between polariser and analyser, a Babinet compensator introduces a known, adjustable phase difference, so it is used to measure retardation and to analyse elliptically polarised light.

Principle of the Wedge Compensator

Quartz is birefringent: light travelling through it splits into two components that move at slightly different speeds, so one falls behind the other. In each wedge the two components are interchanged, because the optic axis of one wedge is parallel to its refracting edge and that of the other is perpendicular to it. At any point across the field, the net phase difference therefore depends on the difference between the two wedge thicknesses at that point.

Since the wedges taper in opposite directions, that difference changes steadily across the field. Between crossed polariser and analyser, the field shows a set of straight, parallel dark bands wherever the retardation is a whole number of wavelengths, with the central band marking zero retardation. Turning the screw slides one wedge and moves the bands across a fixed cross-wire.

Calibration and Measurement

The compensator is first calibrated with monochromatic light, typically from a sodium lamp. The screw reading is noted as the cross-wire is set on successive dark bands; the screw travel between two neighbouring bands corresponds to a retardation of one full wavelength.

A specimen such as a thin mica sheet or a quarter-wave plate is then placed in the beam with its axes at 45 degrees to the polariser. The bands shift; resetting the cross-wire on the displaced central band and dividing that screw travel by the travel for one band gives the specimen’s retardation as a fraction of a wavelength. The same procedure, combined with rotation of the analyser, finds the axes and ellipticity of elliptically polarised light.

Specifications

Optical elements Two crystalline quartz wedges with optic axes at right angles
Adjustment Screw that slides one wedge across the field
Reading Fixed cross-wire with screw scale (usual design)
Used with Polariser, analyser, monochromatic source, optical bench
Screw scale and mounting Confirm at enquiry

Optics Practicals

  • Measuring the retardation of mica sheets and wave plates
  • Analysing elliptically polarised light: axes and ellipticity
  • Distinguishing linear, circular and elliptical polarisation
  • Calibrating screw travel against wavelength with a sodium source

Care & Handling

  • Handle the compensator by its mount; fingerprints on the quartz faces scatter light and blur the bands.
  • Clean optical faces only with a lens tissue and, if needed, a drop of lens-cleaning fluid.
  • Turn the screw gently and approach each setting from the same direction to avoid backlash.
  • Store in its case, away from dust, damp and sudden temperature changes.

Why Choose LabEquip

These quartz-wedge compensators are bought by university and postgraduate physics laboratories that teach polarisation beyond Malus’s law. LabEquip lists it among its physics equipment together with the polarizer and analyzer and optical bench it is mounted with, and set-up questions can be raised through the contact page.

Frequently Asked Questions

How does a Babinet compensator differ from a Soleil compensator?

A Babinet compensator gives a retardation that varies across the field, producing a band pattern. A Soleil compensator adds a parallel plate so the retardation is uniform over the whole field, which suits measurements with photometric detection.

Why are dark bands seen between crossed polarisers?

Where the retardation is a whole number of wavelengths, light leaves the compensator with its original polarisation and is blocked by the crossed analyser, giving a dark band.

Why must the source be monochromatic for calibration?

The band spacing depends on wavelength. With white light only the central band stays dark and the others become coloured, which is useful for finding zero but not for calibration.

How is the retardation of a specimen calculated?

Divide the screw travel needed to return the central band to the cross-wire by the screw travel for one band spacing. The result is the retardation as a fraction of a wavelength.

Why is the specimen set at 45 degrees to the polariser?

At 45 degrees the incident light splits into two equal components along the specimen’s axes, so its effect on the band pattern is clear and easy to measure.

What else is needed with the compensator?

A polariser, an analyser, a monochromatic source such as a sodium lamp and a bench or stand to align them. A telescope or eyepiece helps when reading the bands.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
USD United States (US) dollar
Product has been added to your cart
Compare (0)