Quick Answer: The Fluorescent Microscope, Advanced Research is the advanced-level fluorescence microscope in LabEquip’s range, the level of instrument usually chosen by research labs imaging specimens labelled with more than one fluorescent dye. An advanced fluorescent microscope separates each dye’s signal with matched filter sets.
Working with More Than One Label
Much research fluorescence work uses two or three dyes in one specimen: a blue nuclear stain, a green-labelled antibody and a red-labelled second antibody, for example. Each dye is viewed through its own filter cube, and the images are compared or overlaid. The quality of the separation depends on the filters. If the green channel lets some red emission through, or the red dye is weakly excited by blue light, the channels bleed into each other and a protein appears to be where it is not.
Imaging is the other demand. Multi-label work is almost always recorded with a camera rather than drawn, because the channels are captured one at a time and merged in software; a sensitive monochrome camera on a trinocular port is the usual arrangement. The listing does not specify the camera provision, light source, number of filter positions or objectives, so agree these against the experiments you plan.
Compared with the Research model, Advanced Research is the higher tier by name, although the listing does not itemise what it adds. Labs moving from single-stain teaching work to multi-label research are its natural buyers.
Applications
- Double and triple immunofluorescence in cell biology and immunology
- Fluorescence in situ hybridisation (FISH) for chromosome and gene studies
- Checking green fluorescent protein (GFP) expression in cells, plants or small model organisms
- Biofilm and microbial ecology studies with fluorescent stains
Care & Handling
- Keep a written record of which filter cube sits in which position on the advanced fluorescent microscope, so no image is captured through the wrong channel.
- With a lamp-based light source, let it warm up and stabilise before quantitative imaging, and avoid switching it on and off repeatedly.
- Store unmounted filter cubes in a closed, dust-free box; coated filters are damaged by fingerprints and humidity.
- Clean immersion oil off objectives after each session, because dried oil can fluoresce and raise the background.
Specifications
| Technique | Fluorescence microscopy with a filter cube for each dye |
| Typical work | Multi-label immunofluorescence and co-localisation |
| Recording | Camera imaging with channels merged in software |
| Related models | Research and Malaria Detection fluorescent microscopes |
| Light source, filter positions and camera provision | Confirm at enquiry |
Why Choose LabEquip
Research groups in cell biology, immunology, genetics and microbiology that need more than one fluorescent channel are the buyers of the Advanced Research model. It is part of the LabEquip Microscope & Optics range; list your dyes and camera requirements on the contact page.
Frequently Asked Questions
What is bleed-through?
Signal from one dye appearing in another dye’s channel because their excitation or emission colours overlap. It is reduced by choosing well-separated dyes, using narrow filter sets and imaging each channel separately.
Which dye combinations are commonly used together?
A blue nuclear stain such as DAPI, a green dye such as fluorescein or green fluorescent protein, and a red dye such as rhodamine or Texas Red. Their colours are far enough apart for standard filter sets to separate them.
Why use a monochrome camera for fluorescence?
A monochrome sensor collects all the light at every pixel, while a colour sensor filters it through a colour mosaic and loses much of it. For faint signals, capturing each channel in monochrome and assigning colours in software gives brighter, cleaner images.
What immersion oil should be used?
A low-fluorescence immersion oil. Ordinary oils can glow under ultraviolet or blue excitation and add a haze to every image.
How do I check co-localisation of two proteins?
Image each channel separately with the same field and focus, then merge them in software. Overlap appears as a mixed colour, such as yellow from green and red, but a sound conclusion needs controls and correlation analysis, not colour alone.
How does Advanced Research differ from the Research model?
Advanced Research is the higher tier by name, aimed at multi-label research. The listing does not itemise the differences, so compare the number of filter positions, light source and camera provision on both quotations.