The StemAids Guardian 5000 Sectional Block for Vials is a laboratory hotplate-stirrer accessory designed to hold sample vials securely during heating, sample preparation, reagent warming, and routine testing applications. It is suitable for chemistry, biology, pharmaceutical, industrial, academic, and research laboratories where vial-based sample handling is required.
Product Description
The Guardian 5000 Sectional Block for Vials by StemAids is used with compatible Guardian 5000 and Guardian 7000 hotplate stirrer systems. The sectional block helps laboratories arrange sample vials in a stable and organized manner during controlled heating procedures.
This vial block is useful for laboratories that perform sample warming, chemical testing, reagent preparation, analytical work, and educational demonstrations. Different sectional block options are available for specific vial diameters, allowing users to select the correct size according to their laboratory vial requirement.
Key Features
- Designed for holding laboratory sample vials during heating applications
- Compatible with Guardian 5000 and Guardian 7000 hotplate stirrer accessory systems
- Available for 12 mm, 15 mm, 17 mm, 21 mm, and 28 mm vial sizes
- Helps improve vial stability during supervised laboratory heating
- Useful for sample preparation, reagent warming, and analytical workflows
- Suitable for academic, research, pharmaceutical, QC, and industrial laboratories
- Size-specific block selection supports accurate laboratory procurement
Product Specifications
| Product Name | StemAids Guardian 5000 Sectional Block for Vials |
|---|---|
| Brand | StemAids |
| Product Type | Sectional Vial Heating Block / Hotplate Stirrer Accessory |
| Compatible Equipment | Guardian 5000 and Guardian 7000 hotplate stirrer systems |
| Vial Size Options | 12 mm, 15 mm, 17 mm, 21 mm, and 28 mm vials |
| Application | Sample heating, reagent warming, solution preparation, vial-based testing, and laboratory demonstrations |
| Recommended Users | Schools, colleges, universities, R&D labs, pharmaceutical labs, testing labs, and industrial laboratories |
| Required Accessories | Compatible base plate and handle accessories may be required for proper installation and safe handling |
| Usage Condition | Use only with compatible heating equipment and under trained laboratory supervision |
| Safety Note | Allow the block to cool before handling; use heat-resistant gloves or suitable laboratory tools |
How to Use StemAids Guardian 5000 Sectional Block for Vials
- Select the correct sectional block according to the vial outer diameter.
- Install the compatible base plate on the Guardian 5000 or Guardian 7000 hotplate stirrer as per the equipment manual.
- Place the sectional vial block securely on the base plate.
- Insert clean, suitable, and undamaged sample vials into the block openings.
- Add the required sample or reagent into the vials according to the laboratory procedure.
- Set the required heating temperature on the hotplate stirrer.
- Monitor the process carefully during heating.
- After completion, switch off the equipment and allow the block to cool completely.
- Remove the vials using heat-resistant gloves or suitable laboratory tools.
- Clean and store the block in a dry laboratory cabinet after use.
Applications
- Chemistry sample preparation
- Reagent warming and solution preparation
- Pharmaceutical and quality-control testing
- Biology and environmental sample processing
- Academic laboratory demonstrations
- Research and development workflows
- Batch heating of sample vials in an organized arrangement
Why Choose StemAids?
StemAids supplies laboratory and educational equipment for institutions that require practical, procurement-ready, and application-focused products. The StemAids Guardian 5000 Sectional Block for Vials is suitable for users who need a size-specific vial holding accessory for controlled heating and sample preparation workflows.
- Clear vial-size selection for accurate ordering
- Suitable for schools, colleges, universities, and professional laboratories
- Useful for chemistry, biology, pharmaceutical, and industrial applications
- Supports organized sample placement during heating procedures
- Procurement-friendly details for quotations, tenders, and lab purchase lists
Care and Safety Instructions
- Do not touch the sectional block immediately after heating.
- Always use heat-resistant gloves, tongs, or approved laboratory tools.
- Do not use cracked, damaged, or incorrect-size vials.
- Do not exceed the operating limits of the connected heating system.
- Allow the block to cool completely before cleaning.
- Clean with a soft cloth and avoid abrasive cleaning methods.
- Store in a clean, dry, and safe laboratory location after use.
SEO Keywords
Guardian 5000 sectional block for vials, StemAids sectional vial block, Guardian 5000 vial block, Guardian 7000 vial block, hotplate stirrer vial holder, sectional block 12 mm vials, sectional block 15 mm vials, sectional block 17 mm vials, sectional block 21 mm vials, sectional block 28 mm vials, laboratory vial heating block, chemistry lab vial block, sample preparation vial holder.
Frequently Asked Questions
What is the Guardian 5000 Sectional Block for Vials used for?
It is used to hold sample vials securely during heating, reagent warming, sample preparation, and routine laboratory testing procedures.
Which vial sizes are available?
Common sectional block options are available for 12 mm, 15 mm, 17 mm, 21 mm, and 28 mm vials.
Is this compatible with Guardian 5000 hotplate stirrers?
Yes, it is intended for use with compatible Guardian 5000 and Guardian 7000 hotplate stirrer accessory systems.
Does this sectional block require a base plate?
Yes, a compatible base plate and handle accessories may be required for proper installation and safe handling.
Can one sectional block fit all vial sizes?
No. Each sectional block is made for a specific vial diameter. Users should select the correct size according to the vial outer diameter.
Can it be used in school and college laboratories?
Yes, it can be used in school, college, university, and training laboratories when operated under proper supervision.
How should the block be cleaned?
Allow the block to cool completely before cleaning. Wipe it with a soft cloth and follow the safety instructions provided for the connected heating equipment.
You must be logged in to post a review.










Reviews
There are no reviews yet.