Search

In Stock

Analog rotary drum shaker

8,650.00

The StemAids Analog Rotary Drum Shaker is a compact laboratory rotator designed for gentle, uniform, and continuous mixing of biological samples, reagents, blood samples, suspensions, and laboratory solutions. It is suitable for schools, colleges, research laboratories, clinical laboratories, biotechnology labs, pharmaceutical labs, and routine sample preparation work.

Product Description

The Analog Rotary Drum Shaker by StemAids provides smooth rotary mixing for laboratory tubes and sample containers. Its gentle rolling action helps maintain sample uniformity without aggressive shaking, making it suitable for delicate biological and chemical samples.

This analog rotary shaker is designed for simple operation, compact bench placement, and continuous laboratory use. It is commonly used for mixing blood samples, biological fluids, reagents, buffers, suspensions, and diagnostic samples. The analog control system allows easy speed adjustment, making it suitable for teaching laboratories and routine laboratory workflows.

Key Features

  • Analog speed control for simple and easy operation.
  • Gentle rotary drum movement for effective sample mixing.
  • Suitable for biological samples, reagents, suspensions, and clinical samples.
  • Compact benchtop design for space-saving laboratory use.
  • Continuous operation mode for routine laboratory workflows.
  • Compatible with multiple tube sizes using suitable accessories.
  • Low-noise and stable performance during operation.
  • Suitable for school, college, research, clinical, and pharmaceutical laboratories.
  • Easy to clean and maintain after laboratory use.

Product Specifications

Product Name Analog Rotary Drum Shaker
Brand StemAids
Instrument Type Analog rotary drum shaker / classic laboratory rotator
Control Type Analog speed control
Mixing Action Rotary rolling action
Speed Range Approx. 0-80 rpm
Operation Mode Continuous operation
Motor Type DC motor
Tilt Angle Approx. 90°
Tube Compatibility 1.5 mL, 15 mL, and 50 mL tubes with suitable accessories
Power Supply 100-240 V, 50/60 Hz
Power Consumption Approx. 20 W
Protection Class IP21
Approximate Dimension 300 × 220 × 310 mm
Approximate Weight 2.0 kg
Permissible Ambient Temperature 5°C to 40°C
Permissible Relative Humidity Up to 80% RH
Application Area Biology labs, chemistry labs, clinical labs, research labs, pharmaceutical labs, and educational laboratories

Applications

  • Gentle mixing of biological samples.
  • Blood sample mixing and anticoagulant blending.
  • Mixing of reagents, buffers, and laboratory solutions.
  • Preparation of suspensions and sample mixtures.
  • Clinical diagnostic sample preparation.
  • Biochemistry and molecular biology laboratory work.
  • Educational demonstrations in school and college laboratories.
  • Routine sample agitation in research and testing laboratories.

How to Use the Analog Rotary Drum Shaker

  1. Place the rotary drum shaker on a clean, dry, and stable laboratory bench.
  2. Connect the instrument to the recommended power supply.
  3. Select the correct tube holder or drum accessory according to the tube size.
  4. Place tubes evenly in the holder to maintain proper balance.
  5. Ensure all tube caps are tightly closed before operation.
  6. Switch on the instrument.
  7. Adjust the speed using the analog control knob as per the sample requirement.
  8. Allow the samples to rotate for the required mixing duration.
  9. After mixing, turn the speed control to minimum and switch off the unit.
  10. Remove the tubes carefully and clean the instrument surface if required.

Safety and Handling Guidelines

  • Do not overload the tube holder or rotary drum.
  • Always balance tubes evenly before starting the instrument.
  • Use only properly capped tubes to prevent sample leakage.
  • Do not touch or adjust the rotating part while the shaker is running.
  • Keep the instrument away from water, corrosive liquids, and strong chemical vapours.
  • Wear laboratory gloves, safety goggles, and a lab coat while handling samples.
  • Disconnect the power supply before cleaning or changing accessories.
  • Use the equipment under trained laboratory supervision.

Why Choose StemAids Analog Rotary Drum Shaker?

StemAids offers laboratory instruments suitable for educational institutions, research laboratories, diagnostic labs, and procurement-based laboratory setups. The Analog Rotary Drum Shaker is designed for simple operation, gentle sample handling, and dependable routine mixing performance.

  • Suitable for schools, colleges, universities, and research laboratories.
  • Simple analog control system for easy laboratory operation.
  • Compact design suitable for limited bench space.
  • Useful for biology, chemistry, clinical, and pharmaceutical sample preparation.
  • Procurement-friendly product details for laboratory catalogues, quotations, and institutional tenders.

Frequently Asked Questions

1. What is an Analog Rotary Drum Shaker used for?

It is used for gentle and continuous mixing of tubes, biological samples, reagents, blood samples, suspensions, and laboratory solutions.

2. Is this shaker suitable for biological samples?

Yes. Its gentle rotary motion makes it suitable for biological samples, clinical samples, biochemistry work, and molecular biology applications.

3. What is the speed range of the shaker?

The reference analog rotary drum shaker offers an adjustable speed range of approximately 0-80 rpm.

4. Does this model have a digital display?

No. This is an analog model with manual speed control. For digital speed and timer display, a digital rotary drum shaker model may be selected.

5. Can it be used continuously?

Yes. The analog rotary drum shaker is designed for continuous operation within recommended laboratory conditions.

6. Which tube sizes can be used?

It can be used with common laboratory tube sizes such as 1.5 mL, 15 mL, and 50 mL when suitable holders or accessories are used.

7. Is it suitable for school and college laboratories?

Yes. It is suitable for biology labs, chemistry labs, STEM labs, college laboratories, and routine educational demonstrations.

8. How should the shaker be maintained?

Keep the instrument clean and dry, avoid overloading, balance the tubes properly, and disconnect the power supply before cleaning or changing accessories.

SEO Keywords

Analog rotary drum shaker, StemAids rotary drum shaker, laboratory tube rotator, analog lab shaker, rotary shaker for test tubes, blood sample mixer, biological sample rotator, laboratory rotary mixer, tube rotator for clinical lab, rotary drum shaker for biology lab, educational laboratory shaker.

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)