Receiver Adapter, Vertical With Vacuum Connection

Standard Taper CNC-Ground Joints: Features a 1:10 ratio, interchangeable ground-glass interfaces with a high-vacuum matte finish, ensuring hermetic sealing and universal compatibility across modular glassware systems.

Reinforced Serrated Vacuum Port: Engineered with a specialized hose nozzle designed for high-tensile connection to vacuum tubing, enabling stable depressurization without compromising structural integrity under thermal stress.

$4.85

Quick Answer: A vertical vacuum receiver adapter is a glass fitting that carries distillate straight down from a condenser into the receiver and has a side tube for connecting a vacuum line. It is used where the condenser stands upright or the receiver must sit directly beneath it during reduced-pressure work.

Straight Path, Vacuum Take-Off

Upright condensers are common in solvent recovery and in compact stills, and vacuum set-ups often use them because a vertical coil or double-surface condenser drains fully. This adapter continues that line into the receiver while its side tube takes the vacuum tubing, so pumping happens after condensation. Keep the side tube above the drip so liquid cannot run into the line.

Choosing between this and the bent vacuum adapter comes down to geometry. If the condenser slopes, the bent version brings the receiver upright; if the condenser is already vertical, this one avoids an unnecessary bend. It also works at normal pressure, with the side tube serving as a vent or as the inlet for a gentle stream of nitrogen.

Applications

  • Solvent removal under reduced pressure using a vertical condenser and a round-bottomed receiver
  • Vacuum distillation with downward-pointing condensers
  • Collecting distillate under nitrogen, with the side tube connected to a gas line and bubbler
  • Venting a vertical atmospheric distillation through a guard tube

Care & Handling

  • Place a cold trap between the side tube and the pump, and make sure the trap is cold before evacuating.
  • Evacuate only undamaged round-bottomed receivers, with a safety screen in front of the apparatus.
  • Clip every joint; a vertical stack under vacuum can separate suddenly when air is readmitted.
  • Readmit air slowly through the line once heating has stopped and the flask has cooled.

Specifications

Type Receiver adapter, vertical, with vacuum connection
Flow path Straight down from condenser to receiver
Side connection Tube for vacuum or gas tubing
Suited to Vertical condensers and upright receivers

Why Choose LabEquip

Labs recovering solvents or distilling under reduced pressure with vertical condensers buy this adapter to complete the train. LabEquip supplies it in its chemistry lab equipments section along with the bent vacuum receiver adapter for sloping condensers; confirm joint sizes via the contact page.

Related Products

Frequently Asked Questions

When should I choose a vertical vacuum adapter rather than a bent one?

Choose by condenser geometry. If the condenser slopes, a bent vacuum adapter brings the receiver upright; if the condenser is already vertical, as coil and double-surface condensers often are, the vertical adapter continues the line without an unnecessary bend.

Where should the tubing from the vacuum side tube go?

Run thick-walled vacuum tubing from the side tube to a cold trap, and from the trap to the pump or water aspirator. Keep the side tube above the drip point so liquid cannot run into the line.

Why is a cold trap needed between the adapter and the pump?

Some vapour always passes the condenser under reduced pressure. A cold trap condenses it before it reaches the pump, protecting the pump oil or mechanism and stopping solvent from being discharged. It also keeps the pressure steadier.

Can a vertical vacuum adapter be used without a vacuum?

Yes. At normal pressure the side tube serves as a vent, or as the inlet for a gentle stream of nitrogen through a bubbler. Leave it open or fit a drying tube whenever the receiver is sealed onto the adapter.

What makes the vacuum poor at the receiver adapter?

Common causes are dry or dirty ground joints, a cracked or perished length of tubing, a loose tubing connection on the side tube, or a joint that is not fully pushed home. Check each joint and connection in turn, and grease vacuum joints lightly.

Which receivers can be used on a vertical vacuum adapter?

Only round-bottomed or pear-shaped flasks with ground necks, which withstand reduced pressure. Never use flat-bottomed or conical flasks as vacuum receivers, and inspect every flask for cracks before pumping down.