Quick Answer: A dairy pipette is a glass pipette used in milk testing to measure a set volume of milk, or of a reagent, into a butyrometer for the Gerber fat test. It is used in dairy plants, milk collection centres and dairy technology laboratories.
The Gerber Test and Its Pipettes
The Gerber method, developed by the Swiss chemist Niklaus Gerber in the 1890s, remains a routine way of measuring the fat content of milk. Concentrated sulfuric acid of a specified strength is placed in a butyrometer, a measured volume of milk is added from a pipette, followed by a little amyl alcohol. The acid dissolves the proteins surrounding the fat globules, the butyrometer is spun in a centrifuge and warmed in a water bath, and the released fat rises into the graduated stem, where its percentage is read directly.
Because the butyrometer scale assumes a fixed quantity of milk, the milk pipette is central to accuracy. In the Gerber method as widely practised the milk pipette delivers 10.75 ml, although some older and national procedures use 11 ml, and the acid and amyl alcohol are dispensed by separate pipettes or automatic measures.
Milk pipettes are usually of the one-mark type, so the technique follows that of a volumetric pipette: fill above the mark with a pipette filler, let the level fall to the mark, and deliver against the inner wall of the butyrometer neck.
Applications
- Routine fat testing of milk at dairy plants and milk collection centres
- Dairy technology and food science practicals on milk composition
- Quality checks on standardised, toned and skimmed milk
- Testing at collection points where payment to farmers depends on fat content
Specifications
| Item | Glass pipette for the Gerber milk fat test |
| Used with | Butyrometer, Gerber centrifuge, water bath |
| Measured liquid | Milk sample, or a reagent such as sulfuric acid or amyl alcohol, depending on type |
| Type | Usually a one-mark delivery pipette |
Care & Handling
- Mix the milk sample gently but thoroughly before drawing it up, so the fat is evenly distributed.
- Use a pipette filler for every liquid, and never draw sulfuric acid by mouth.
- Rinse first with cold or lukewarm water, since hot water sets milk proteins on the glass, then wash with detergent and rinse with distilled water.
- Discard pipettes with chipped tips, which deliver inaccurate volumes.
Why Choose LabEquip
Dairy cooperatives, milk testing laboratories and dairy technology colleges buy dairy pipettes alongside butyrometers for routine Gerber testing. LabEquip lists them in its chemistry lab equipment; state your test method and the volume required on the contact page.
Related Products
- Lactometer: A dairy lactometer for checking milk density, a quick screen to run alongside the fat test.
- Study kit for Milk Components: A milk components study kit for showing the protein, fat, lactose and minerals in milk.
- Pipette Filler, 3 way: A three-valve pipette filler for drawing milk up the pipette without mouth pipetting.
- Pipette Stand (Vertical): A vertical pipette stand for draining dairy pipettes tip down after washing.
- Brush, Pipette: A long, slim pipette brush for removing milk film from inside the pipette bore.
Frequently Asked Questions
What is a dairy pipette used for in milk testing?
A dairy pipette measures a set volume of milk, or of a reagent, into a butyrometer for the Gerber fat test. The butyrometer scale assumes that exact quantity of milk, so the dairy pipette is what makes the fat percentage read from the scale correct.
How is the Gerber milk fat test carried out?
Sulfuric acid of the specified strength goes into the butyrometer first, then the measured milk is run in gently down the side so it layers on the acid, followed by a little amyl alcohol. The butyrometer is stoppered, shaken, spun in a Gerber centrifuge and warmed in a water bath before the fat column is read.
Why should milk be at a set temperature before pipetting?
Milk volume and fat distribution change with temperature, and cold milk may hold fat in clumps or cream. Methods specify warming and mixing the sample gently to a set temperature, then cooling it to the measuring temperature, so the pipette takes a fair, representative volume.
Can the same dairy pipette be used for milk and for acid?
Separate pipettes are used. Milk pipettes and acid or amyl alcohol measures are made for different volumes, and using one for both risks carry-over between sample and reagent. Concentrated sulfuric acid is normally dispensed with an automatic measure or tilt measure, never sucked up by mouth.
How should milk be delivered from the pipette into the butyrometer?
Hold the butyrometer at an angle and let the milk run slowly down the inside wall so it floats on the acid instead of mixing at once. Rushing it causes local charring and heat. Let the pipette drain fully and touch the tip against the neck to finish.
How are dairy pipettes cleaned after use?
Rinse them with cold water straight away to remove milk before it dries, then wash with warm detergent solution, rinse with clean water and stand them tip down to drain. Hot water first can set milk proteins on the glass and leave a film.
Last Updated: November 2026










Reviews