Search

In Stock

Hofmann Electrolysis Apparatus

$26.58

Quick Answer: The Hofmann voltameter, also called the Hofmann electrolysis apparatus, is a three-limbed glass apparatus for electrolysing water and collecting the hydrogen and oxygen separately. The listing photo shows two graduated side tubes with stopcocks, a central reservoir tube topped by a bulb, and electrodes entering through stoppers at the base, all held on a stand.

How the Three Limbs Work Together

The apparatus takes its name from the chemist August Wilhelm von Hofmann. Its two outer limbs are graduated gas-collecting tubes, each closed at the top by a stopcock and fitted at the bottom with an electrode sealed through a stopper. The central limb, open at the top and widening into a bulb, is the reservoir: it joins the outer tubes at the base and keeps them filled with electrolyte.

With the stopcocks open, the electrolyte, usually water made conducting with a little dilute sulfuric acid or sodium sulfate, is poured into the central limb until both outer tubes are full, and the stopcocks are then closed. When direct current flows, hydrogen collects above the cathode and oxygen above the anode. After a few minutes the hydrogen column is visibly about twice as long as the oxygen column, the 2:1 ratio that matches the formula of water.

Because the gases are trapped in graduated tubes, their volumes can be read and each gas tested at its stopcock. The Brownlee electrolysis apparatus collects gases in tubes standing in a jar instead, and the mini electrolysis device is a compact alternative for student benches.

Specifications

Item Hofmann-type electrolysis apparatus (voltameter)
Glassware Two graduated side tubes with top stopcocks and a central reservoir limb with bulb (photo)
Electrodes Enter the side tubes through stoppers at the base (photo)
Support Stand with clamps (photo)

Applications

  • Demonstrating the 2:1 volume ratio of hydrogen to oxygen from the electrolysis of water
  • Testing the collected gases with lighted and glowing splints
  • Relating the charge passed to the volume of gas produced in Faraday’s law investigations
  • Comparing the rate of gas production with different electrolyte concentrations

Care & Handling

  • Fill the Hofmann voltameter with dilute electrolytes only, and wear eye protection when filling and draining it.
  • Use a low-voltage DC supply, and switch it off before touching the electrode connections.
  • Never release both gases together near a flame; test one stopcock at a time with the other closed.
  • Drain, rinse with distilled water and store with the stopcock keys loosened so that they do not stick.

Why Choose LabEquip

The Hofmann voltameter is bought by teachers who would rather a class measured the composition of water than simply be told it. It is one of LabEquip’s chemistry lab equipment listings; ask on the contact page about electrode type and a suitable power supply.

Related Products

  • Hofmann Voltameter: A three-limbed Hofmann voltameter listed separately, of the same design for collecting the two gases apart.
  • Brownlee Electrolysis Apparatus: A Brownlee jar-type electrolysis cell, a simpler alternative for showing the gases form at each electrode.
  • Mini Electrolysis Device: A compact electrolysis device with small collecting tubes for students to run on their own bench.
  • Electrolysis Carbon Rod: A graphite electrode rod for comparing electrolysis of other solutions with inert carbon electrodes.

Frequently Asked Questions

Why is the volume of hydrogen twice the volume of oxygen?

Water is H2O, so electrolysis releases two molecules of hydrogen for every molecule of oxygen. Equal numbers of gas molecules occupy equal volumes at the same temperature and pressure, so the hydrogen tube above the cathode fills about twice as fast as the oxygen tube above the anode.

Why is the measured ratio of gases often slightly more than 2 to 1?

Oxygen is more soluble in water than hydrogen, so a little of it dissolves in the electrolyte at first. Some oxygen may also react with the anode or form other products. Running the apparatus for a few minutes and discarding the first gas, before measuring, brings the ratio closer to 2 to 1.

What electrolyte should be used in a Hofmann apparatus?

Pure water conducts too poorly, so a little dilute sulfuric acid or sodium sulfate solution is added. Both give hydrogen and oxygen at the electrodes while the dissolved ions carry the current. Avoid sodium chloride, because chlorine is produced at the anode instead of oxygen.

How is the Hofmann electrolysis apparatus filled?

With both stopcocks open, pour the electrolyte into the central reservoir limb until it rises to the top of the two graduated side tubes, then close the stopcocks. The liquid in the central tube keeps the side tubes full, and the gases then collect at the tops of the side tubes as electrolysis runs.

How are the gases from electrolysis of water tested?

Run a little gas out through a stopcock into an inverted test tube. Hydrogen burns with a squeaky pop when a lighted splint is held at the mouth, and oxygen relights a glowing splint. Release only small amounts and keep flames away from the apparatus itself.

What power supply does a Hofmann voltameter need?

It needs a low-voltage direct current supply, such as a school power pack on its DC setting or a set of cells. Alternating current would mix the gases in both tubes. Connect the negative terminal to the electrode under the tube where hydrogen is to collect.

Last Updated: November 2026

Reviews

There are no reviews yet.

Write a review

Back to Top