Search

In Stock

Desiccator (Vacuum)-All Clear, Plastic

High-Tensile Polycarbonate Architecture: Fabricated from premium, impact-resistant polycarbonate that offers 360-degree specimen visibility and superior durability, engineered to maintain a 740mm Hg vacuum for over 24 hours without structural deformation.

Precision Grease-Free Stopcock: Integrated with a specialized PTFE-plugged vacuum valve for leak-proof performance and easy disconnection, paired with a heavy-duty silicone O-ring seal to ensure hermetic integrity without the requirement for external lubricants.

$11.62

Quick Answer: A plastic vacuum desiccator is a transparent moulded container with a sealing lid and a stopcock, used to dry or store samples in dry air under reduced pressure. The all-clear version lets users see the samples and desiccant from every side and removes the risk of glass fragments if it is dropped.

Reduced Pressure Speeds Drying

Pumping the air out of a desiccator lowers the pressure around the samples. Water and residual solvent then evaporate more readily at room temperature, and the vapour is taken up by the drying agent or removed by the pump. That makes a vacuum desiccator quicker than an ordinary one for drying crystals, filter papers and heat-sensitive materials that cannot go into an oven.

The title states only that the unit is all clear and plastic. Polycarbonate has limits worth knowing: acetone, chlorinated solvents and strong alkalis can craze or cloud it, so solvent-wet samples should be pre-dried before they go inside.

Compared with the borosilicate glass desiccator, the plastic body is lighter and far less likely to break, which suits teaching labs and field stations. Glass remains the choice for warm crucibles and for samples that give off aggressive vapours.

Specifications

Item Vacuum desiccator with lid, stopcock and sample plate
Body All-clear plastic, per the listing title
Vacuum control Stopcock for evacuation and slow venting
Seal Lid gasket; grease not normally required

Care & Handling

  • Evacuate gradually and vent slowly through the stopcock; opening it fully at once can blow light powders off the plate.
  • Keep the lid gasket clean and free of cracks, and never apply solvents to it.
  • Wipe the body with water and mild detergent only; avoid acetone and other solvents that craze clear plastics.
  • Do not place hot items inside, and check the rated vacuum limit before using a high-vacuum pump.

Applications

  • Drying recrystallised products at room temperature after suction filtration
  • Removing air bubbles from casting resins or silicone mixtures before pouring
  • Storing moisture-sensitive reagents and electronic components in dry air
  • Keeping dried biological or soil samples dry before weighing

Why Choose LabEquip

Teaching laboratories, field stations and pharmacy stores that want vacuum drying without the breakage risk of glass tend to pick a plastic vacuum desiccator. LabEquip includes it among its chemistry lab equipment; capacity and body material can be confirmed on the contact page.

Related Products

  • Filter Pump: A water-jet filter pump that provides enough suction to evacuate the desiccator from a laboratory tap.
  • Manual Vacuum Pump: A hand-operated vacuum pump for evacuating small vessels where no tap or mains supply is available.
  • Vacuum Tube, Rubber: Heavy-walled rubber vacuum tubing that connects the stopcock to the pump without collapsing.
  • Desiccator, Borosilicate Glass: A borosilicate glass desiccator for cooling hot crucibles, which a plastic body should not take.

Frequently Asked Questions

How does a vacuum desiccator dry samples faster?

Pumping air out lowers the pressure around the samples, so water and residual solvent evaporate more readily at room temperature and the vapour is taken up by the drying agent or drawn off by the pump. That makes a vacuum desiccator quicker than an ordinary one for crystals, filter papers and materials that cannot go into an oven.

How do you evacuate and release a plastic vacuum desiccator?

Seat the lid on its gasket, connect the stopcock to the pump with thick-walled vacuum tubing, open the stopcock and pump until the lid is held down firmly, then close the stopcock and disconnect the pump. To open it, turn the stopcock very slowly so air re-enters gently, and lift the lid only when the pressure has equalised.

Why should the vacuum in a desiccator be released slowly?

A sudden rush of air through the stopcock can blow fine powders and crystals off their dishes and stir up desiccant dust. Releasing the vacuum slowly also stops the inrushing air from carrying moisture straight onto the samples. Some users fit a drying tube on the inlet so the air that enters is already dry.

Which pump can be used with a plastic vacuum desiccator?

A water filter pump on a tap or a hand-operated vacuum pump is enough for most drying work. An electric rotary pump gives a lower pressure but needs a cold trap or drying tower to protect it from solvent vapour. Whatever the pump, a trap bottle in the line stops water or oil being drawn back into the desiccator.

Which solvents can damage a clear plastic desiccator?

All-clear vacuum desiccators are commonly moulded in polycarbonate, which is attacked by acetone, chlorinated solvents and strong alkalis, and can craze when exposed to solvent vapour under stress. Keep samples wet with those solvents out of it, or dry them in a glass vacuum desiccator instead, and clean the plastic with mild detergent only.

Is a plastic vacuum desiccator safer than a glass one?

A plastic body does not shatter into sharp fragments if it is dropped or knocked, which is a real advantage for student use. It should still be inspected for cracks or crazing before each evacuation and kept away from heat sources, since warm plastic is weaker under vacuum. Vacuum glassware of any kind is best used behind a safety screen.

Last Updated: November 2026

Reviews

There are no reviews yet.

Write a review

Back to Top