Cylinder, Nessler

Optically Clear Plane-Parallel Base: Features a precision-ground, fire-polished flat bottom that eliminates optical distortion, ensuring a uniform light path length and maximum transmittance for accurate visual colorimetry and spectrophotometric consistency.

Matched Volumetric Tolerances: Fabricated with uniform internal diameters and permanent, fire-fused graduation marks at standardized heights to ensure exact volume alignment across multiple units for side-by-side comparative analysis.

₹230.00

Quick Answer: A Nessler cylinder is a tall, flat-bottomed glass tube with an etched mark, used in pairs or sets to compare the colour or cloudiness of solutions by looking down through the liquid. It is the vessel for the Nessler ammonia test in water and for pharmacopoeial limit tests.

Comparing Colour Down a Long Column

Faint colours are hard to judge across the width of a test tube but much easier looking down a long column of liquid. The Nessler cylinder is built for that view: a tall, narrow tube with a flat, clear base, filled to a mark so that every solution in a comparison has the same depth. Two cylinders stand side by side on a white surface, one holding the sample and one a standard, and the analyst looks straight down through both.

The name comes from Nessler’s reagent, an alkaline solution of potassium tetraiodomercurate(II) that turns yellow to brown with ammonia, the classic test for ammonia in water samples. The same cylinders are used for pharmacopoeial limit tests, in which the faint opalescence produced by chloride or sulfate in a sample is compared with a standard, and for colour tests such as the limit test for iron.

Matched cylinders are important. If the glass tint, wall thickness or height to the mark differ between tubes, the comparison is biased. Cylinder capacity, mark volume and whether a stopper is fitted are not stated in the listing.

Applications

  • Estimating ammonia in water samples with Nessler’s reagent
  • Chloride and sulfate limit tests in pharmaceutical analysis practicals
  • The limit test for iron, compared against a standard solution
  • Teaching visual colorimetry before students move on to a colorimeter

Care & Handling

  • Keep matched sets together and do not mix cylinders from different sets in one comparison.
  • View sample and standard under the same light against the same white tile, then swap their positions to check the judgement.
  • Nessler’s reagent contains mercury: wear gloves and eye protection, and collect waste for proper disposal instead of pouring it down the sink.
  • Keep the bases free of scratches and deposits, which scatter light and make turbidity comparisons unreliable.

Specifications

Item Tall, flat-bottomed colour-comparison tube
Viewing Vertically, through the full depth of liquid, over a white base
Mark Etched mark for filling to a fixed depth
Use Visual colorimetry and turbidity comparison against standards
Capacity and mark volume Confirm at enquiry

Why Choose LabEquip

Water-testing laboratories, pharmacy colleges running limit tests and chemistry departments teaching colorimetry buy these comparison tubes in sets, often with a bulb type pipette for measuring the sample. LabEquip lists them in the chemistry lab equipment range; to order matched sets, use the LabEquip contact page.

Frequently Asked Questions

Why is the Nessler cylinder viewed from above?

Looking down the length of the tube passes light through a deep column of liquid, which makes pale colours and slight cloudiness much easier to see than looking through the side.

What is the cylinder used to test for?

It is a comparison vessel rather than a test in itself. It is used for any visual comparison against a standard, most famously ammonia with Nessler’s reagent, and the chloride, sulfate and iron limit tests of pharmaceutical analysis.

Why do the cylinders need to be matched?

The comparison assumes both solutions are viewed through identical glass at identical depth. Differences in height to the mark, wall tint or base thickness change how dark a solution appears and bias the result.

How is a limit test carried out in the cylinders?

The sample is prepared in one cylinder and a standard containing the permitted amount of impurity in another, with the same reagents in both. After the stated time, the sample passes if its colour or opalescence is no more intense than the standard’s.

Is Nessler’s reagent hazardous?

Yes. It contains a mercury compound and potassium hydroxide, so it is toxic and corrosive. Use gloves and eye protection, prepare it in small amounts, and dispose of mercury-containing waste according to local rules.

Can a colorimeter replace Nessler cylinders?

A colorimeter or spectrophotometer gives numerical absorbance readings and is more objective. Visual comparison cylinders remain useful for pharmacopoeial limit tests written around visual comparison and for teaching the principle of colorimetry.