Rack for 15/50 ml Centrifuge Tubes

Dual-Diameter Universal Geometry: Precision-molded architecture features specialized well diameters to accommodate both 15mL and 50mL conical tubes, optimizing benchtop footprint and multi-protocol versatility.

Enhanced Thermal Resilience: Manufactured from high-density, reinforced polypropylene capable of withstanding repeated autoclave sterilization cycles at 121°C and maintaining structural integrity in ultra-low temperature mechanical freezers.

₹540.00

Quick Answer: This centrifuge tube rack has holes sized for the two common conical centrifuge tube sizes, 15 ml and 50 ml, so these cone-bottomed tubes can stand upright on the bench. It keeps tubes steady while they are filled, labelled, capped and carried to the centrifuge.

Holding Two Tube Sizes in One Rack

Conical tubes cannot stand on their own because of their pointed base, apart from self-standing versions with a moulded skirt. Racks for this pair of sizes come in a few layouts: one rack with rows of both hole sizes, a two-sided rack with 15 ml holes on one face and 50 ml holes on the other, or an interlocking set.

In cell culture rooms the rack sits inside the biosafety cabinet while cells are harvested into 15 ml tubes or media is split into 50 ml aliquots. Holding both sizes in one footprint saves space on the cabinet floor and keeps the air grilles clear. Extraction work uses it the same way: samples are spun in 50 ml tubes, then the supernatant moves to 15 ml tubes for the next step.

Polypropylene racks can usually be autoclaved as well as wiped with disinfectant, while racks of other plastics may only tolerate chemical disinfection. If the rack will also stand in a water bath, remember that part-filled tubes are buoyant and can lift out of their holes.

Specifications

Tube sizes 15 ml and 50 ml conical centrifuge tubes (per title)
Function Holds cone-bottom tubes upright
Material Moulded plastic
Cleaning Detergent wash or disinfectant wipe; autoclave only if the material allows

Applications

  • Holding tubes in a biosafety cabinet during cell harvesting and media preparation
  • Organising 50 ml tubes of soil, water or food homogenate before centrifugation
  • Keeping aliquots upright in a fridge or cold room
  • Sorting tubes by sample before loading a swing-bucket centrifuge

Care & Handling

  • Put the heavier 50 ml tubes towards the middle so the rack does not tip.
  • Wipe spills at once, especially culture media, which dries into a sticky film.
  • Mark rack positions with tape if the same layout is used repeatedly.
  • Autoclave only racks marked as polypropylene or autoclavable.

Why Choose LabEquip

Cell culture labs, microbiology teaching labs and clinical training centres that handle conical tubes every day need a stable place for them on the bench. LabEquip stocks this rack in the Biology Lab Products range together with a rack for micro centrifuge tubes for smaller volumes; ask about layout on the contact page.

Related Products

Frequently Asked Questions

Why do 15 ml and 50 ml centrifuge tubes need a rack?

Most 15 ml and 50 ml tubes have a conical base and cannot stand up on their own. A rack holds them upright while they are filled, labelled, capped and carried to the centrifuge, which prevents spills and mix-ups. This rack has positions for both of these common sizes.

How are racks for two tube sizes usually laid out?

There are several common layouts: one rack with rows of both hole sizes, a two-sided rack with 15 ml holes on one face and 50 ml holes on the other, or interlocking units. Whatever the layout, the narrow 15 ml tubes need smaller holes so they stay vertical rather than leaning in a 50 ml space.

Can self-standing 50 ml tubes go in a centrifuge tube rack?

Yes. Self-standing tubes have a moulded skirt so they stand alone on a flat bench, but they still fit the rack’s 50 ml positions. Keeping all tubes in a rack is safer when the bench is busy, because a knocked tube in a rack does not roll.

Can a plastic centrifuge tube rack be autoclaved?

It depends on the plastic. Polypropylene racks generally withstand autoclaving, while racks of polystyrene or ABS warp at autoclave temperatures and should be disinfected with a suitable chemical wipe instead. For routine cleaning, a wash in warm detergent and a rinse is enough.

How should tubes be balanced before going into the centrifuge?

Use the rack to line up tubes in pairs of equal volume and the same type, and place each pair opposite each other in the rotor. If there is an odd number of samples, fill a blank tube with water to the same level. An unbalanced rotor vibrates and can damage the centrifuge.

How do you keep track of many tubes in a crowded rack?

Label each tube on the side and the cap before filling it, work along the rack in a fixed order and write a simple rack map in your notebook. Leaving an empty position between groups of samples makes it easy to see where one set ends.

Last Updated: November 2026

Reviews

There are no reviews yet.

Write a review