Search

In Stock

PCR Tube Strip

Sub-Micron Wall Tolerance: Engineered with precision-molded thin-wall geometry to minimize thermal resistance, enabling near-instantaneous transition between denaturation and annealing phases for optimized enzymatic reaction efficiency.

Optical-Grade Hermetic Sealing: Features high-compression flat caps designed for maximum light transmission and leak-proof integrity, significantly reducing evaporative loss while maintaining signal clarity in sensitive fluorescence-based assays.

$3.38

Quick Answer: A PCR tube strip is a row of thin-walled PCR tubes moulded together, most often eight in a row, closed by a matching strip of caps that is either hinged to the tubes or supplied separately. Strips sit in a thermal cycler block in the same positions as a 96-well plate.

Between Single Tubes and a Full Plate

Strips suit runs that are too large for a handful of single tubes but too small to justify a whole plate. Sixteen samples fit in two strips, and a multichannel pipette dispenses master mix into all eight tubes of a strip in one stroke, which cuts pipetting time and reduces the chance of skipping a tube.

The caps deserve the closest look. Domed caps seal tightly and are common for end-point PCR, while flat caps give an even optical surface and are the usual choice for qPCR instruments that read fluorescence through the cap. Cap strips may be hinged to each tube or pressed on as a separate strip after loading.

Because the tubes are joined by a thin web, a strip can be cut into shorter lengths with clean scissors when only three or four reactions are needed. For real-time runs, label the strip ends or tube sides rather than the cap tops.

Applications

  • qPCR on a few samples in triplicate with no-template controls
  • Diagnostic training exercises where each strip carries one student group’s samples
  • Reverse transcription reactions ahead of a qPCR step
  • Small genotyping runs that would leave most of a plate empty

Specifications

Format Connected thin-walled PCR tubes, commonly eight per strip
Material Moulded plastic, usually polypropylene for PCR consumables
Fits Thermal cycler blocks laid out like 96-well plates
Loading Single-channel or multichannel pipette

Care & Handling

  • Press every cap down along the whole strip with a capping tool or a gloved finger to prevent evaporation.
  • Keep strips in their bag until use and handle them by the ends, not the caps.
  • Cut strips on a clean surface using scissors wiped with ethanol.
  • Do not reuse strips after cycling; caps and walls deform with heating.

Why Choose LabEquip

Molecular biology teaching labs like strips because each group gets its own row and a multichannel pipette speeds loading. LabEquip stocks them in the Biology Lab Products range next to the full PCR plate; send your cycler model through the contact page if the cap style needs checking.

Related Products

  • PCR Tubes: Single PCR tubes for controls or very small runs alongside the strips.
  • PCR Plate: A 96-well PCR plate for larger runs when several strips would no longer be enough.
  • PCR Tube Rack: An open PCR rack that holds strips along a row during set-up and multichannel loading.
  • PCR Rack with Cover: A covered PCR rack for keeping loaded strips protected in the fridge or on the way to the cycler.

Frequently Asked Questions

What is a PCR tube strip?

A PCR tube strip is a row of thin-walled PCR tubes moulded together, commonly eight per strip, closed by a matching strip of caps. The tubes are usually polypropylene and sit in a thermal cycler block in the same positions as a 96-well plate.

Should I choose flat or domed caps for PCR strips?

Domed caps seal tightly and are common for end-point PCR. Flat caps give an even optical surface and are the usual choice for qPCR instruments that read fluorescence through the cap. Caps may be hinged to each tube or pressed on as a separate strip after loading.

When are PCR strips a better choice than single tubes or a plate?

Strips suit runs too large for a handful of single tubes but too small to justify a whole plate. Sixteen samples fit in two strips, and a multichannel pipette dispenses master mix into all eight tubes of a strip in one stroke, which saves time and avoids skipping a tube.

Can a PCR tube strip be cut into shorter pieces?

Yes. The tubes are joined by a thin web, so a strip can be cut into shorter lengths with clean scissors when only three or four reactions are needed. Cut the matching cap strip the same way so every tube stays sealed.

Why do PCR strip caps pop open during cycling?

Caps lift when they are not pressed fully home, when the heated lid pressure does not suit the strip height, or when cap strips from another type are used. Press each cap down along the whole strip with a cap tool or firm finger and check the cycler lid closes evenly.

Where should PCR strip tubes be labelled for qPCR?

For real-time runs, label the strip ends or the tube sides instead of the cap tops, because ink on the caps can block the fluorescence read through them. Record the strip order on a plate map so each tube’s position in the block is known.

Last Updated: November 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
USD United States (US) dollar
Product has been added to your cart
Compare (0)