Search

In Stock

Multi-Functional Nursing Manikin

Holistic Anatomical Integration: Features a life-sized, articulated frame with realistic joint kinesiology, allowing for complex patient positioning, decubitus ulcer care, and orthopedic nursing simulations.

Biomimetic Clinical Ports: Equipped with self-sealing subcutaneous and intramuscular injection sites, alongside functional orifices for gastric lavage, urethral catheterization, and ostomy maintenance using medical-grade elastomeric polymers.

$28.88

Quick Answer: The multi-functional nursing manikin is a full-body adult training manikin designed to support many nursing procedures on one body. Nursing colleges use a multi-functional nursing manikin to practise bedside care together with airway, feeding tube, catheter, injection and wound care skills at a single skills lab station.

One Manikin, Many Procedures

A manikin with many functions reduces the number of separate task trainers a skills lab needs. Procedures commonly supported by manikins of this type include oral and nasal suctioning, tracheostomy care, oxygen delivery, nasogastric tube insertion and feeding, male and female catheterisation with interchangeable parts, enema, injections into the arm, thigh or buttock, and dressing of wounds or stomas.

The advantage shows in integrated scenarios. Instead of practising a single task, a student can admit a simulated patient, reposition them, suction the airway, check a feeding tube before a feed and record the care given, the way a real shift runs. Tutors can also build assessments in which students must choose the right procedure, not only perform it.

Tracheostomy care is one skill where a full-body manikin helps, because the stoma, tube and ties have to be managed on a neck that can be positioned. Students learn to clean the stoma and change the dressing and ties with a second person holding the tube, and to suction through the tube with sterile technique, keeping each pass short. The advanced nursing and wound care manikin is listed for wound-focused teaching.

Specifications

Item Full-body adult nursing manikin with multiple functions
Typical functions Airway care, tube feeding, catheterisation, injections, wound and stoma care
Scenario use Integrated patient care and OSCE stations
Users Nursing colleges, hospital education units, allied health programmes

Applications

  • Integrated nursing scenarios in college skills labs
  • Tracheostomy care, suctioning and oxygen therapy practicals
  • Tube feeding, catheterisation and injection practice on one manikin
  • OSCE stations where students select and perform procedures

Care & Handling

  • Keep a checklist of the manikin’s inserts and accessories and check it after each session, since parts are easily scattered across a busy lab.
  • Clean and dry every passage used in a practical, such as the airway and the stomach and bladder reservoirs, before storage to prevent mould.
  • Use water-based lubricant and training fluids only.
  • Lay the manikin flat on a bed or in its case; long periods sitting upright strain the joints.

Why Choose LabEquip

Colleges setting up or expanding a nursing skills lab often place a multi-functional manikin at the centre of the room, with smaller task trainers around it. LabEquip lists it in its biology lab products; share your procedure list through the contact page to check the match.

Related Products

Frequently Asked Questions

Which procedures are practised on a multi-functional nursing manikin?

This manikin is listed for airway care, tube feeding, catheterisation, injections, and wound and stoma care. Manikins of this kind let a student move from suctioning to nasogastric feeding to catheter care on one adult body, as in a real shift on a ward.

What is the advantage of a multi-functional manikin over separate task trainers?

One full-body manikin replaces several part-task trainers and lets students practise integrated patient care: admitting, positioning, suctioning, feeding and recording care on the same simulated patient. It also suits OSCE stations, where students must choose the right procedure, not only perform it.

How is nasogastric tube position checked on a nursing manikin before a feed?

Students practise the checks taught in their course, most commonly aspirating stomach contents and testing them with pH paper, and documenting the external tube length. Feeding only after the position is confirmed by the approved method is a key safety point rehearsed on the manikin.

How long should each suction pass last during airway suctioning practice?

Suction passes are kept brief, commonly no more than about 10 to 15 seconds, because suction removes oxygen as well as secretions. Students practise pre-oxygenating, applying suction only while withdrawing the catheter, and allowing recovery between passes on the manikin’s airway.

Can one nursing manikin be used for both male and female catheterisation?

Many manikins of this type use interchangeable genital parts so that both male and female urinary catheterisation can be practised with sterile technique. The manikin’s own function list shows which inserts are fitted; a combination model such as this is chosen when one manikin must serve both.

How should a nursing manikin be cleaned and stored after a skills session?

Drain any fluid reservoirs, wipe the skin with mild soapy water and dry it, and avoid ink pens and newsprint, which stain vinyl permanently. Lubricate only with the recommended lubricant, store the manikin lying flat or seated, and keep removable parts together so no inserts are lost.

Last Updated: November 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
USD United States (US) dollar
Product has been added to your cart
Compare (0)