Search

In Stock

Maternity Examination Model

Modular Cervical Inserts: Equipped with a series of interchangeable cervical modules representing various stages of dilation and effacement to simulate realistic labor progression scenarios.

Anatomical Fetal Landmarks: Includes a life-sized fetal model with palpable fontanelles and sutures, enabling precise training in identifying fetal presentation, position, and variety during vaginal examinations.

₹1,205.00

Quick Answer: The maternity examination model is an antenatal training model of a pregnant woman’s abdomen, used to practise the routine checks of pregnancy. Midwifery and nursing students use a maternity examination model to learn abdominal inspection, measuring fundal height, palpation of the baby and listening for the fetal heart.

The Routine Antenatal Examination

Each antenatal visit in later pregnancy follows a familiar sequence, and the model lets students practise it in order. Inspection comes first, noting the size and shape of the abdomen, scars and stretch marks. Fundal height is then measured with a tape from the top of the pubic bone to the top of the uterus; from about 24 weeks the number of centimetres roughly matches the number of weeks of pregnancy, so a result well outside that range is plotted and investigated.

Palpation follows, to find the baby’s lie, presentation and engagement, and then auscultation. The fetal heart is heard with a Pinard stethoscope or a handheld Doppler, usually over the baby’s back, and the rate is counted for a full minute.

A model is particularly useful for learning to measure fundal height consistently, because results vary between examiners and students need practice with a fixed technique. The detailed palpation sequence is covered on the Leopold maneuvers simulator, and the pelvimeter is listed for pelvic measurement teaching.

Specifications

Item Pregnant abdomen model for antenatal examination
Examinations practised Inspection, fundal height, palpation, fetal heart auscultation
Tools used with it Tape measure, Pinard stethoscope or handheld Doppler
Users Midwifery and nursing students, community health workers

Care & Handling

  • Keep the abdominal surface of the maternity examination model clean with mild soap and water, and keep ink and markers off the skin.
  • Use ultrasound gel sparingly for Doppler practice and wipe it off after each session so it does not dry onto the surface.
  • Store the model lying flat or in its case with nothing stacked on the abdomen.

Applications

  • Antenatal examination practicals in midwifery and nursing programmes
  • Teaching symphysis-fundal height measurement and growth charts
  • Practising fetal heart auscultation with Pinard and Doppler devices
  • Community health worker training in antenatal care

Why Choose LabEquip

Midwifery schools and antenatal care programmes buy examination models so students can repeat the full antenatal check without tiring a volunteer. It is in LabEquip’s biology lab products; send questions through the contact page.

Related Products

  • Leopold Maneuvers Simulator: A Leopold maneuvers simulator for practising the four abdominal grips used in the palpation step of the examination.
  • Pregnant Woman’s Belly: A median section through the abdomen in late pregnancy showing the uterus and fetus beneath the abdominal wall.
  • Gynecological Examination Model: A gynaecological examination trainer for speculum and bimanual examination skills taught in the same course.
  • Labour Delivery Model: A labour delivery model for continuing from antenatal checks to the birth of the head and shoulders.

Frequently Asked Questions

What can be practised on a maternity examination model?

The model is a pregnant abdomen for rehearsing the routine antenatal check in order: inspection of the abdomen, measuring fundal height with a tape, palpating the baby and listening for the fetal heart with a Pinard stethoscope or handheld Doppler. Midwifery and nursing students and community health workers use it.

How is symphysis-fundal height measured?

With the woman lying back and her bladder empty, find the top of the uterus with the side of the hand. Lay the tape from there to the top of the pubic bone, keeping the centimetre side face down until the end so the reading is not biased, then turn it over and read. From about 24 weeks the height in centimetres roughly matches the weeks of pregnancy.

Why is fundal height plotted on a growth chart?

One measurement means little on its own, but a series plotted on a chart shows the growth trend. A measurement that is static or falling away from the expected curve may point to slow fetal growth, and one well above it may suggest twins or extra amniotic fluid. Either pattern leads to an ultrasound scan.

Where is the fetal heart heard best on the abdomen?

The heart is heard most clearly through the baby’s back. In a head-down baby that is usually below the navel on the side where the back was felt; in a breech baby it is higher, near or above the navel. Palpating first to find the back saves time searching with the stethoscope.

What is the difference between a Pinard stethoscope and a handheld Doppler?

A Pinard is a trumpet-shaped tube the midwife listens through directly; it needs no power and hears the actual heart sounds, but works best later in pregnancy. A handheld Doppler uses ultrasound, can pick up the heartbeat earlier, lets parents hear it too, and needs batteries and gel.

What is the normal fetal heart rate range at term?

A normal baseline fetal heart rate is generally taken as 110 to 160 beats per minute. Count for a full minute and feel the mother’s pulse at the same time, so her heartbeat is not mistaken for the baby’s. Rates persistently outside this range need further assessment.

Last Updated: November 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)