Search

In Stock

Cryo Vial-Internal Thread

Silicone Gasket Sealing: An integrated leak-proof internal thread design with medical-grade silicone seals maintains vacuum integrity across temperatures ranging from -196°C to +121°C.

Conical Internal Geometry: The optimized interior base facilitates maximum sample recovery and low residual volume, which is critical for high-value biological reagents and diagnostic assays.

$3.55

Quick Answer: The Cryo Vial-Internal Thread is a small plastic storage vial for ultra-low temperature work, in which the cap screws down inside the vial’s mouth. An internal thread cryovial is used to freeze and store cell lines, microbial stocks, sera and tissue samples at −80 °C or in liquid nitrogen vapour, with the sample kept sealed until it is thawed.

Internal Versus External Thread

Cryovials are made with two thread designs. On an internal thread cryovial the cap has a threaded plug that screws into the vial, so the outer diameter stays the same from base to cap and vials pack closely in a box grid. On external thread vials the cap screws over the outside of the neck. Because the internal design puts the cap’s plug into the vial opening, the sample must be kept clear of the thread when filling; external threads are sometimes preferred where contact between cap and sample is a contamination concern.

Cryovials are usually polypropylene, and many designs seal the cap against the vial with a silicone washer or O-ring. A white writing area and printed graduations are common, and a star-shaped or skirted foot lets many vials stand on their own and lock into racks.

Safe cryogenic storage depends on fill level and storage phase. Vials should not be filled above their stated working volume, leaving room for the contents to expand as they freeze. Storage in the vapour phase above liquid nitrogen is generally preferred to submerging vials, because liquid nitrogen can seep into a submerged vial and then expand violently when it warms. For a screw-cap vial meant for ordinary storage, see the Storage Vial With O-Ring.

Applications

  • Freezing cell lines in freezing medium for long-term banking
  • Storing bacterial and yeast glycerol stocks at −80 °C
  • Aliquoting serum, plasma and antibodies to avoid repeated freeze-thaw cycles
  • Keeping tissue and biopsy samples for later molecular analysis

Filling, Freezing and Thawing

  • Fill below the working volume mark, and keep liquid off the threads
  • Label with cryo-grade labels or markers before freezing
  • Store in the vapour phase, or use a protective sleeve if liquid-phase storage cannot be avoided
  • Wear a face shield when taking vials out of liquid nitrogen, and thaw them in a closed container or behind a screen

Specifications

Type Cryogenic storage vial
Thread Internal: the cap screws inside the vial
Typical material Polypropylene vial and cap
Storage −80 °C freezers and liquid nitrogen vapour phase

Why Choose LabEquip

Cryovials of this design are a staple order for cell culture labs, microbiology departments, biobanks and hospital research units. LabEquip supplies them with Cryo Coders and cryo boxes in Biology Lab Products; ask about volume and sterility through our contact page.

Related Products

  • Cryo Rack: A bench rack that holds cryovials upright and steady while they are filled and capped.
  • Cryo Box (PP): A polypropylene cryo box with a numbered grid for storing filled vials at -20 °C or -80 °C.
  • Cryo Coders: Coloured cap inserts that press into the vial cap to colour-code samples.
  • Storage Vial With O-Ring: A screw-cap storage vial with an O-ring seal for aliquots kept in a refrigerator or freezer rather than in nitrogen.

Frequently Asked Questions

What is the difference between internal and external thread cryovials?

On an internal thread cryovial the cap has a threaded plug that screws inside the vial mouth, so the outside stays the same width from base to cap and vials pack closely in a box. On an external thread vial the cap screws over the outside of the neck, which keeps the threads away from the sample.

How full should a cryovial be filled before freezing?

Do not fill a cryovial above its stated working volume. Liquid expands as it freezes, and an overfilled vial can crack or force its cap. With an internal thread vial, keep the liquid clear of the thread so the plug does not dip into the sample.

Why are cryovials usually kept in nitrogen vapour rather than liquid?

If a vial is stored submerged, liquid nitrogen can seep past the seal; when the vial is warmed the nitrogen boils and the vial can burst. Storage in the vapour phase above the liquid avoids this, and the internal thread cryovial is meant for -80 °C freezers and nitrogen vapour.

How should a frozen cryovial of cells be thawed?

Cells are normally thawed fast, in a 37 °C water bath, holding the vial so the cap stays above the water. Rapid thawing limits ice crystal damage. Wipe the outside with 70% ethanol before opening in the cabinet, and dilute the cells into warm medium to reduce DMSO exposure.

Can cryovials be autoclaved and reused?

Cryovials are normally used once. Reusing them risks a poor seal, because autoclaving can distort the threads and the washer, and a vial that leaks in a freezer can contaminate a whole box. Polypropylene vials can be autoclaved for decontamination before disposal.

What labels work on cryovials in the freezer?

Use labels or markers made for cryogenic temperatures and write on the white writing area while the vial is dry and at room temperature. Ordinary labels can peel off at -80 °C or in nitrogen vapour. Record the vial’s box position in the inventory as a back-up.

Last Updated: November 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
USD United States (US) dollar
Product has been added to your cart
Compare (0)