Search

In Stock

Crimp Top Vials

Precision-Milled 11mm Crimp Finish: Optimized neck geometry ensures uniform aluminum seal compression for a vacuum-tight, tamper-evident closure and leak-proof performance during needle penetration.

Hydrolytic Class 1 Borosilicate Matrix: Low-expansion glass prevents pH shifts and ion leaching, preserving analyte purity during long-term storage and high-sensitivity detection.

₹270.00

Quick Answer: Crimp Top Vials are small sample vials whose neck is sealed by crimping an aluminium cap with a septum over it. Crimp top vials are mainly used to hold samples for gas chromatography (GC) and high-performance liquid chromatography (HPLC) autosamplers, where a tight seal limits evaporation.

How a Crimp Seal Works

The vial neck has a flat rim with a lip underneath. A cap made of thin aluminium, holding a septum of rubber or silicone often faced with PTFE, is placed over the rim, and a hand crimper squeezes the cap’s skirt under the lip. The result is a seal that stays tight even with volatile solvents, which is why crimp vials are often chosen for GC. The autosampler needle pierces the septum, draws the sample and withdraws, and the septum largely closes again.

Compared with screw-top vials, crimp vials seal more consistently and suit long runs of volatile samples, but they need a crimper to close and a decapper to open, and caps cannot be reused. Screw-top vials are quicker to handle and can be reopened, so they are common for routine HPLC work. Screw cap vials are listed separately for that purpose.

In biology and biochemistry labs, crimp vials hold plant extracts, essential oils, fatty acid methyl esters and other samples prepared for chromatography.

Specifications

Item Crimp top sample vials
Closure Aluminium crimp cap with septum, applied with a crimper
Main use GC and HPLC autosampler samples; sealed small-volume storage
Accessories needed Crimp caps with septa, hand crimper, decapper

Applications

  • GC analysis of essential oils, solvents and fatty acid methyl esters
  • HPLC analysis of plant extracts, pigments and drug samples in pharmacy and biotechnology labs
  • Sealed storage of small volumes of volatile standards
  • Teaching chromatography practicals where students prepare and load their own vials

Filling and Sealing

  • Fill each vial to about three-quarters so the needle does not push sample out and there is room for pressure changes.
  • Set the crimper so the cap is tight enough not to turn by hand but not so tight that the septum bulges or the glass cracks.
  • Place the PTFE face of the septum towards the sample.
  • Discard used vials as chemical waste according to your lab’s rules; do not reuse pierced caps.

Why Choose LabEquip

Analytical chemistry, pharmacy and biotechnology labs order crimp vials in quantity, matched to the caps and autosampler they already use. LabEquip lists them in Biology Lab Products; send the volume, neck size and instrument details through the contact page.

Related Products

  • Screw Cap Vials: Screw cap glass vials, the reopenable alternative when a crimper and decapper are not wanted for routine samples.
  • Vial Block: A metal dry-bath block with a grid of wells for heating or cooling small vials before analysis.
  • Brush, Tubes/Vials: A slim twisted-wire brush sized for cleaning sample vials and culture tubes between uses.
  • Culture Vial/Tube, Amber Glass: Amber glass culture tubes for storing light-sensitive extracts before they are transferred to vials for chromatography.

Frequently Asked Questions

What are crimp top vials used for in GC and HPLC?

Crimp top vials hold small liquid samples in the tray of a gas or liquid chromatography autosampler. The aluminium crimp cap squeezes a septum tightly onto the vial rim, so volatile solvents evaporate very little during a long run, and the injection needle can pierce the septum without the vial being opened.

What tools do I need to seal and open a crimp top vial?

A crimp top vial needs crimp caps with septa and a hand crimper to close it, and a decapper to open it again. The crimper folds the soft aluminium skirt of the cap under the lip of the vial neck; the decapper peels it back. The caps are bent in the process, so a fresh cap is used every time.

Crimp top or screw top vials: which seals better for volatile samples?

A correctly crimped cap gives a very consistent seal, which is why crimp vials are often chosen for volatile samples and long GC sequences. Screw top vials are quicker to close and can be reopened, so they are common for routine HPLC work where evaporation is less of a concern.

How full should a crimp top autosampler vial be filled?

Fill a crimp top vial only to around the shoulder, below the neck, so the septum stays dry and a small air space remains above the liquid. An overfilled vial can push liquid into the septum when it is pierced, and an air space also lets the autosampler draw sample without creating a vacuum.

Which way should the septum face in a crimp cap?

Where the septum has a PTFE face, that side goes towards the sample and the rubber or silicone side faces up to the needle. PTFE resists solvents, so the sample touches only the inert layer, while the elastic layer above helps the hole close again after the needle withdraws.

How can I tell if a crimp top vial cap is crimped correctly?

A good crimp holds the cap firmly, so it does not turn with light finger pressure, while the septum stays flat. A cap that spins is too loose and lets solvent escape; a septum that bulges or dimples means the crimper is set too tight. Adjust the crimper on a spare vial before sealing samples.

Last Updated: November 2026

Reviews

There are no reviews yet.

Write a review

Back to Top