Search

In Stock

Coplin Staining Jar, PP, Domed Cap

₹545.00

Quick Answer: The Coplin Staining Jar, PP, Domed Cap is a Coplin staining jar moulded from polypropylene, with internal grooves that hold microscope slides upright and a domed cap that closes over them. It is used to immerse slides in stains, fixatives and rinses in histology, cytology and microbiology labs.

Polypropylene versus Glass Coplin Jars

A Coplin jar is a small, tall vessel with vertical grooves moulded inside, spaced so that slides stand on edge without touching each other and stain reaches both faces evenly. Rows of Coplin jars, each holding a different reagent, let a batch of slides pass through a staining sequence by simply lifting them from one jar to the next.

This version is made of polypropylene (PP) rather than glass. PP does not shatter when knocked over or dropped into a sink, which matters in student labs, and it is generally resistant to water-based stains, dilute acids and alkalis and alcohols. Polypropylene labware is also commonly autoclavable at 121 °C, though the rating of the specific jar should be checked first. The trade-offs are lower clarity than glass and weaker resistance to aromatic solvents such as xylene, for which a glass Coplin jar is the usual choice.

The domed cap sits higher than a flat lid, leaving headroom above the slide ends so that labels and frosted tops are not pressed or smeared, and it reduces evaporation of alcohols between uses.

Specifications

Item Coplin staining jar for microscope slides
Material Polypropylene (PP), as stated in the product name
Closure Domed cap
Slide position Upright in internal grooves, faces separated

Staining Tasks

  • Haematoxylin and eosin staining sequences in histology teaching
  • Fixing and staining blood and cytology smears
  • Alcohol dehydration series before mounting, where the reagent is compatible with PP
  • Rinsing and holding slides between steps of Gram staining

Using and Cleaning the Jar

  • Label each Coplin staining jar with its reagent and keep it capped when not in use to limit evaporation.
  • Do not use PP jars for xylene or other aromatic solvents; use glass for those steps.
  • Wash with warm water and laboratory detergent; avoid abrasive pads that scratch the grooves.
  • Check the jar’s temperature rating before autoclaving and leave the cap loose in the autoclave.

Why Choose LabEquip

Histology and pathology teaching labs buy PP Coplin jars for the water and alcohol steps where students handle jars most and breakages are likely. LabEquip lists it among its biology lab products; the Euro-design Coplin jar is an alternative in the lab glassware range.

Related Products

  • Coplin Jar: A slotted Coplin jar made in glass or chemical-resistant plastic, depending on variant, for staining, fixing and washing.
  • Coplin jar (Euro Design): A Euro-pattern Coplin jar with internal grooves that hold slides vertically for histology and cytology staining.
  • Staining Jar Rectangular: A rectangular glass staining jar, unaffected by xylene, for taking a larger batch of slides through each reagent.
  • Staining Bar with Stand, Aluminium/Stainless Steel: A raised staining bar on a stand for flood staining slides held level over a sink.
  • Slide Holding Forceps: Self-gripping forceps that hold a slide by one end while it is moved between jars and rinsed.

Frequently Asked Questions

Should I choose a polypropylene or a glass Coplin jar?

A polypropylene jar does not shatter when knocked over or dropped into a sink, which suits student labs, and it handles water-based stains, alcohol solutions and rinses well. Glass is the better choice for xylene and other strong solvents used in clearing, and shows the liquid level and colour more clearly.

What is the domed cap on a Coplin staining jar for?

The domed cap closes over the tops of the slides standing in the jar, cutting evaporation of alcohol-based reagents and the escape of fumes, and keeping dust out between uses. A jar of stain or fixative can then stay set up on the bench between sessions.

How are slides moved through a staining sequence in Coplin jars?

Set up a row of jars, each holding one reagent in order, such as fixative, stain, rinse and counterstain. Lift the slides with forceps from one jar to the next, timing each step and draining excess liquid onto a tissue between jars to reduce carry-over.

Can a polypropylene Coplin jar be autoclaved?

Polypropylene is a plastic that withstands steam autoclaving, so a PP jar can generally be autoclaved with the cap set loosely on top to let pressure escape. Let it cool fully before use, and wash off stain residues before autoclaving so they are not baked onto the plastic.

Does a polypropylene Coplin jar absorb stains?

Some dyes, such as crystal violet and haematoxylin, can tint plastic over time. This does not affect later staining but can make the jar look dirty. Rinse the jar soon after use, and keep dedicated jars for strongly coloured stains.

Why do Coplin jars have grooves inside?

The vertical grooves hold each slide upright on its edge and apart from its neighbours, so the reagent reaches both faces evenly and the slides do not stick together. Some users place two slides back to back in one groove to stain more at once, with specimens only on the outer faces.

Last Updated: November 2026

Reviews

There are no reviews yet.