Quick Answer: These graduated tubes for electrolyzer use are a pair of clear tubes marked with a volume scale and held by a dark holder bar with two openings, as pictured. Filled with electrolyte and stood over the electrodes, the tubes collect the hydrogen and oxygen made in water electrolysis so their volumes can be read and compared.
Collecting Gas by Displacement Inside the Cell
Each tube is filled to the top with the electrolyte, closed with a finger or stopper, turned upside down and lowered over one electrode. The holder bar then keeps both tubes upright and at the right height. As the current flows, gas bubbles rise into each tube and push the liquid down, and the scale shows the volume collected.
Having both gases in identical, side-by-side tubes makes the key result obvious at a glance: the cathode tube gathers hydrogen at about double the rate at which the anode tube gathers oxygen.
Taking Accurate Readings
For the fairest comparison, read the volumes at the same moment and with the liquid level inside each tube level with the liquid outside, so that both gases are at the same pressure. Recording volumes every minute and plotting them against time shows that each gas is produced at a steady rate for a steady current, the starting point for Faraday’s first law.
Specifications
| Product | Graduated gas tubes for an electrolyzer, with holder |
| Shown in photograph | Two clear graduated tubes and a dark holder bar with two openings |
| Function | Collect and measure the gas from each electrode |
| Used with | The platinum electrode electrolyzer and similar cells |
| Graduation range and tube material | Confirm at enquiry |
Uses
- Measuring hydrogen and oxygen volumes during water electrolysis
- Showing the 2:1 volume ratio that matches the formula of water
- Plotting gas volume against time at constant current
- Collecting each gas separately for splint tests
Care & Handling
- Fill tubes completely so no air bubble is trapped at the top before inverting
- Remove the tubes slowly, keeping them upright with a finger over the end if the gas is to be tested
- Rinse with distilled water after use and let them drain upside down
- Store the tubes in their holder or padded so the graduations are not scratched
Why Choose LabEquip
Teachers order matched tubes so that both gases are measured on identical scales side by side. LabEquip supplies them for the platinum electrode electrolyzer and alongside its other physics lab equipment; contact LabEquip to check compatibility with your cell.
Frequently Asked Questions
How are the tubes filled without trapping air?
Fill each tube to the brim with electrolyte, cover the end, invert it under the surface of the liquid in the cell and only then uncover it over the electrode.
Why should the liquid levels be matched before reading?
When the level inside a tube matches the level outside, the gas inside is at room pressure. Comparing volumes at the same pressure keeps the comparison fair.
Which tube fills faster?
The tube over the cathode, which collects hydrogen. It fills about twice as fast as the oxygen tube over the anode.
Can the gases be tested after collection?
Yes. Lift a tube out with the end kept closed and test the gas with a lighted splint for hydrogen or a glowing splint for oxygen.
Will these tubes fit any electrolyzer?
They are made to stand over the electrodes of a compatible electrolyzer with the holder bar resting on it. Check the electrode spacing of your cell against the holder.
Why is a small air bubble a problem?
A trapped air bubble adds to the volume reading and mixes with the collected gas, which spoils both the volume ratio and the splint test.