Variable Parameter Conductimetric Cell

Cellule conductimétrique à paramètres variables. Features a precision-sliding mechanism to vary the distance between platinum-plated electrodes, enabling the empirical study of the cell constant in real-time.

Standardized 4mm Safety Interface Built with high-quality shrouded connectors and a chemical-resistant transparent housing, ensuring secure electrical contact and long-term durability in corrosive laboratory environments

₹1,430.00

Quick Answer: The Variable Parameter Conductimetric Cell is a conductivity cell whose two plate electrodes can be moved along a graduated frame and dipped into a beaker of solution, so both the distance between them and the area immersed can be changed. This conductimetric cell shows where the cell constant of an ordinary conductivity meter comes from.

Conductance, Conductivity and the Cell Constant

A solution conducts because its ions move when a voltage is applied. The conductance G measured between two electrodes, in siemens, depends on the solution and on the geometry: it is proportional to the immersed electrode area S and inversely proportional to their separation L, so G = σS/L, where σ is the conductivity of the solution itself.

Commercial conductivity probes have fixed geometry summarised by a single number, the cell constant L/S. The variable parameter conductimetric cell lets students change L and S separately and see each effect, so the cell constant becomes something they have measured rather than a value printed on a probe.

Running the Experiment

The photograph shows a white backboard with a graduated scale, two plate electrodes held in sliding clips with green fittings, a beaker beneath them and two clamps for mounting. A low alternating voltage from a signal generator is applied, current and voltage are read with AC meters, and G = I/U is calculated.

Keeping the immersion depth fixed while moving one electrode shows G falling as 1/L. Keeping the spacing fixed while lowering the electrodes shows G rising in proportion to the wetted area. Changing the concentration then shows conductivity rising with the number of ions present.

Specifications

Product Conductimetric cell with variable electrode geometry
Electrodes Two plates in sliding holders
Frame Graduated scale for setting separation
Adjustable parameters Electrode spacing and immersed area
Electrode material Confirm at enquiry

Applications

  • Showing that conductance is inversely proportional to electrode spacing
  • Showing that conductance is proportional to the immersed electrode area
  • Measuring how conductivity changes with the concentration of a salt solution
  • Introducing the cell constant used by conductivity meters

Care & Handling

  • Rinse the electrodes with distilled water after each solution and before changing concentration
  • Avoid scratching the electrode plates; wipe them gently with soft tissue
  • Use low alternating voltages only, as advised for the cell
  • Dry the frame and clamps before storage

Why Choose LabEquip

Physics and physical chemistry teachers buy a variable conductimetric cell to show the reasoning behind conductivity measurement, not just the reading. LabEquip supplies it alongside the electrical conductivity pack for solid samples, within its physics equipment; questions about electrode materials can go to the contact page.

Frequently Asked Questions

Why should an alternating voltage be used with the cell?

A steady DC voltage causes electrolysis at the electrodes, releasing gas and building up layers that change the reading over time. An alternating voltage reverses before these effects can build up.

How does electrode spacing affect the reading?

Conductance is inversely proportional to spacing when the immersed area stays the same. Doubling the distance between the plates halves the conductance.

What is the cell constant?

The cell constant is the electrode separation divided by the immersed electrode area. Multiplying a measured conductance by the cell constant gives the conductivity of the solution.

Which solutions are suitable for the cell?

Dilute solutions of common salts such as sodium chloride or potassium chloride in distilled water are suitable. Check that the electrode material suits any acid or other solution before using it.

Why does conductance increase with concentration?

A more concentrated solution contains more ions to carry charge. In dilute solutions the conductance rises almost in proportion to concentration; in stronger ones the ions interfere with each other and the rise slows.

Does temperature affect the readings?

Yes. Ions move faster in warmer water, so conductivity rises noticeably with temperature. Measure all solutions at the same temperature, or record the temperature with each reading.