Weight Set, 1g-2Kg, Class E2

Austenitic Non-Magnetic Stainless Steel Construction: Forged from high-density, corrosion-resistant alloy with a magnetic susceptibility (χ) significantly below 0.01, ensuring zero electromagnetic interference during sensitive mass determination.

Ultra-Low Surface Roughness (Mirror Finish): Precision-polished to a surface finish exceeding 0.5 μm Ra to prevent microscopic particulate accumulation and ensure long-term mass stability across high-frequency calibration cycles.

₹1,820.00

Quick Answer: The Weight Set, 1g-2Kg, Class E2 is a set of reference weights with nominal values from 1 g up to 2 kg, titled in accuracy class E2, one of the highest classes used outside national metrology laboratories. A Class E2 weight set is used to calibrate and check analytical and precision balances and to calibrate lower-class weights.

Where Class E2 Sits in the Hierarchy

Weights are graded into accuracy classes under the international scheme published by the International Organization of Legal Metrology (OIML): E1, E2, F1, F2, M1 and the lower M classes. Each class sets a maximum permissible error for every nominal value, and each step down the scale allows roughly three times the error of the class above. E1 weights link working standards to national mass standards; E2 weights sit just below them and are intended for checking F1 weights and for use with balances of the special accuracy class, which includes analytical balances.

That position defines how an E2 set is used. It is a reference, not a working set: the weights come out of their case to test balances or other weights and go straight back, so that they stay clean and stable between recalibrations.

Calibrating Higher-Capacity Balances

The 1 g to 2 kg range suits top-loading precision balances and analytical balances with larger capacities. A typical check combines three tests. For span, a weight close to capacity confirms that the balance reads correctly at full load. For linearity, several weights across the range show whether the error stays small between zero and full load. For repeatability, one weight is placed and removed several times to give the scatter of readings. Together they tell a laboratory whether its balance can deliver the accuracy its methods require.

Traceability

An E2 weight is useful only when its actual mass is known with a stated uncertainty, which comes from calibration against higher standards in an unbroken chain back to the national standard of mass. Laboratories therefore keep the calibration report with the set and send the weights for recalibration at intervals set by their quality system, or after any damage. Whether a calibration report accompanies this set should be confirmed at enquiry.

Applications

  • Calibration and routine testing of precision and analytical balances up to the kilogram range
  • Calibrating Class F1 and lower weights by comparison
  • Span, linearity and repeatability checks in quality-controlled laboratories
  • Teaching mass metrology in college and university measurement courses

Specifications

Nominal range 1 g to 2 kg, as titled
Accuracy class E2, as titled
Intended use Reference weights for balances and lower-class weights
Handling Gloves, padded forceps and weight lifters; no bare-hand contact
Piece list, material, case and calibration report Confirm at enquiry

Care & Handling

  • Handle the Class E2 weight set only with lint-free gloves, padded forceps or a weight lifter, and lift kilogram pieces with two hands or a lifting fork.
  • Let the weights stand in the balance room until they reach its temperature; the heaviest pieces take longest.
  • Clean only when needed, with a soft brush or lint-free cloth; after any solvent cleaning, let the weight stabilise and consider recalibration.
  • Keep the case closed, and log any drop or damage so the piece can be rechecked.

Why Choose LabEquip

Quality-controlled laboratories, calibration services and metrology teaching labs buy E2 sets in the kilogram range to cover their larger balances. LabEquip lists this set in its Physics Equipments range; for analytical-range work the 1 mg to 500 g Class E2 weight set is also available. Please share your balance capacities and documentation needs through the contact page.

Frequently Asked Questions

What does Class E2 mean?

It is an accuracy class for weights in the international classification used in legal metrology. E2 is the second highest class, below E1, and allows only very small deviations from nominal mass. It is used to check F1 weights and balances of the special accuracy class.

Which balances can a 1 g to 2 kg E2 set calibrate?

It suits precision top-loading balances and analytical balances whose test loads fall within the set’s range. The weight class should be chosen so that its permissible error is small compared with the balance’s own tolerance.

Why must E2 weights be handled with gloves?

Skin deposits oil, salt and moisture that add mass and can corrode the surface, and hand warmth changes the weight’s temperature. At E2 level both effects are large enough to spoil a calibration.

How long should weights acclimatise before use?

Until they match the temperature of the balance room. The time depends on the temperature difference and the size of the weight; larger pieces take longer, and leaving the set in the room overnight is common practice.

What is traceability for a weight set?

It means the actual mass of each weight is known through a documented chain of calibrations back to the national standard of mass, each step with a stated uncertainty. A calibration report records the values and uncertainties.

How often should an E2 set be recalibrated?

Intervals are set by the laboratory’s quality system, based on how often the weights are used and how stable their values have been. Any piece that is dropped, scratched or contaminated should be rechecked before further use.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)