Quick Answer: The Precision 500mA DC Ammeter is a direct-current meter with a full-scale reading of 500 milliamperes, used to measure current in low-voltage circuit practicals. In its usual moving-coil form, a 500 mA DC ammeter gives a pointer reading that is proportional to the current flowing through it.
The Moving-Coil Principle
In a moving-coil meter a light coil of fine wire is pivoted between the poles of a permanent magnet. Current through the coil produces a turning force that is balanced by fine hairsprings, so the coil, and the pointer fixed to it, turns through an angle proportional to the current. A low-resistance shunt in parallel with the coil carries most of the current, setting the full-scale reading at 500 mA. Because the force reverses with current direction, the meter is polarised: current must enter at the positive terminal.
Precision meters of this kind usually have a finely divided scale and a mirror strip beside it. Reading with the eye placed so the pointer hides its own reflection removes parallax error. Whether this meter has a mirror scale, and its scale divisions, should be checked when ordering.
Connecting and Reading the Ammeter
An ammeter always goes in series, so that the current being measured flows through it. Break the circuit at the point of interest and connect the meter into the gap, positive terminal towards the positive side of the supply. Never connect an ammeter directly across a supply or a component: its resistance is very low and the large current that flows can damage it at once.
Before switching on, check that the pointer rests on zero and adjust the zero screw if not. Choose a circuit in which the expected current is within 500 mA, and keep a rheostat or resistor in series while setting up. Readings in the upper part of the scale are the most precise, since the fixed reading uncertainty is then a smaller fraction of the value.
Practicals
- Verifying Ohm’s law with a voltmeter and a resistor
- Plotting the current-voltage characteristic of a 6V lamp
- Measuring current in series and parallel branches
- Finding the internal resistance of a cell
- Timing a steady current in electrolysis practicals
Specifications
| Quantity measured | Direct current |
| Full-scale reading | 500 mA (from the title) |
| Usual movement | Permanent-magnet moving coil with pointer |
| Connection | In series, observing polarity |
| Scale divisions, mirror scale and accuracy class | Confirm at enquiry |
Care & Handling
- Connect the meter in series only, positive terminal to the positive side of the circuit.
- Start with a series resistor or rheostat set high and reduce it gradually.
- Set the pointer to zero with the adjusting screw before each session.
- Keep the meter away from strong magnets and avoid knocks, which can damage the pivots.
Why Choose LabEquip
Schools and colleges buy 500 mA ammeters for the low-current circuits that make up most electricity practicals, usually one per bench with a matching voltmeter. LabEquip lists it among its physics equipment, and meter requirements for a laboratory can be discussed through the contact page.
Frequently Asked Questions
Why must an ammeter be connected in series?
The meter measures the current that passes through it. Only in series does the whole of the circuit current flow through the meter, so only then is the reading the current in that part of the circuit.
What happens if the ammeter is connected across a supply?
Its resistance is very low, so a very large current flows. This can burn out the shunt or coil and bend the pointer against its stop.
Why does the pointer move backwards?
The current is entering at the negative terminal. Switch off and swap the two connections; a moving-coil meter only reads current in one direction.
How do I convert milliamperes to amperes?
Divide by 1000. A reading of 250 mA is 0.25 A, and the meter’s full-scale reading of 500 mA is 0.5 A.
Why is a mirror placed beside the scale on precision meters?
The mirror shows the reflection of the pointer. When the eye is placed so the pointer hides its reflection, the line of sight is perpendicular to the scale and parallax error is removed.
How is the meter checked for accuracy?
Connect it in series with a meter of known accuracy, such as a calibrated digital multimeter, and compare readings at several currents across the scale.
Last Updated: October 2026










Reviews
There are no reviews yet.