Search

In Stock

Linear Expansion Apparatus

Precision Micrometer Integration: Features a built-in micrometer screw gauge providing 0.01mm resolution, enabling the high-sensitivity measurement of longitudinal rod displacement during thermal excitation.

Multi-Material Thermal Jacket: Constructed with a heavy-duty, plated steam chamber that accommodates various test rods—including brass, copper, and steel—supported by dual-point thermometer ports for verifying uniform thermal equilibrium.

₹570.00

Quick Answer: The Linear Expansion Apparatus is used to measure the coefficient of linear expansion of a metal rod by heating it, usually with steam in a surrounding jacket, and measuring the very small increase in its length with a fine screw. It is a standard heat practical in senior secondary and undergraduate physics.

What the Linear Expansion Apparatus Measures

The coefficient of linear expansion, written as alpha, is the fractional increase in length for each degree of temperature rise: alpha = increase in length divided by (original length times rise in temperature). For common metals it is a very small number, so a rod of laboratory length heated from room temperature to that of steam grows by well under a millimetre. The apparatus is designed to heat the rod uniformly and read that tiny change reliably.

In the usual arrangement the rod sits inside a metal tube or jacket with a steam inlet and outlet and a side opening for a thermometer. The lower end of the rod rests against a fixed stop, and its upper end is approached by a fine screw, often a spherometer-type or micrometer screw, whose divided head allows very small movements to be read.

Running the Experiment

First measure the rod’s length at room temperature and note that temperature. Place the rod in the jacket and turn the screw down until it just touches the rod end; record the reading. Then withdraw the screw a few turns, pass steam through the jacket and wait until the thermometer reading stops rising. Turn the screw down again to the new contact point. The difference between the two screw readings is the expansion, and the difference between the two thermometer readings is the temperature rise.

Making contact with the same light pressure each time decides the accuracy, and repeating the hot reading after a few more minutes of steam confirms that the rod had reached a steady temperature.

Specifications

Type Apparatus for the coefficient of linear expansion of a solid rod
Heating method Steam passed through a jacket around the rod (usual design)
Expansion measured with Fine screw with divided head brought into contact with the rod end
Temperature measured with Thermometer inserted into the jacket
Rods, screw type and thermometer supplied Confirm at enquiry

Practical Uses

  • Determining the coefficient of linear expansion of brass, copper, aluminium or iron rods
  • Comparing the values found for two metals to explain the action of a bimetallic strip
  • Practising contact readings with a micrometer-type screw and correcting for backlash
  • Discussing why engineers leave expansion gaps in rails, pipelines and bridges

Care & Handling

  • Drain condensed water from the jacket after use and leave it open to dry so it does not corrode inside.
  • Allow the jacket and rod to cool before removing the rod; both stay hot after the steam is turned off.
  • Never force the screw hard against the rod, which damages the thread and the rod end.
  • Keep the rubber steam tubing secured so it cannot spring off while hot.

Why Choose LabEquip

Physics departments in schools and colleges buy the linear expansion apparatus for the practical examinations in which a measured value of alpha is required. The bar pyrometer makes a good companion for the introductory demonstration, and the full range sits in our physics equipment category. For the rods and accessories a class set needs, reach LabEquip through the contact page.

Frequently Asked Questions

What formula is used with the linear expansion apparatus?

Alpha equals the increase in length divided by the product of the original length and the temperature rise. With lengths in metres and temperatures in degrees Celsius or kelvin, the answer is per kelvin; the values for common metals are of the order of ten to twenty millionths per kelvin.

Why is steam used to heat the rod instead of a flame?

Steam surrounds the whole rod and holds it at an almost constant temperature close to the boiling point of water, so every part of the rod is at the same, measurable temperature. A flame heats unevenly and gives no reliable rod temperature.

How do I know when the screw just touches the rod?

Turn the screw slowly and stop at the first resistance felt through the head. Some set-ups add a simple circuit with a cell and a bulb or galvanometer, so that contact completes the circuit. Always approach the rod from the same direction.

Which rods can be tested in the apparatus?

Any straight metal rod that fits the jacket and stands on the base stop can be tested; brass, copper, aluminium and steel are the usual choices. The rods sent with the apparatus are stated in the quotation, so extra metals can be requested at the same time.

Why must the rod length be measured at room temperature?

Alpha is defined relative to the original length, so the cold length is the one used in the formula. Measuring a hot rod would make a small error, but more importantly it is unsafe to handle the rod once steam has passed.

What are the main sources of error in this experiment?

Backlash in the screw, uneven contact pressure, taking the hot reading before the rod reaches a steady temperature and misreading the thermometer. Because the expansion is so small, a slip at the screw matters far more than an error in the rod length.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top