Search

In Stock

Duct Damper for Fume Hood

Corrosion-Resistant Polypropylene Housing: Molded from chemical-grade PP, the damper resists degradation from aggressive acid fumes and solvent vapors, ensuring long-term structural integrity in corrosive exhaust streams.

Multi-Diameter Compatibility: Available in standardized configurations (150mm to 250mm), the manual butterfly valve mechanism allows for fine-tuned volumetric flow control to balance static pressure across laboratory ventilation systems.

₹580.00

Quick Answer: The Duct Damper for Fume Hood is an adjustable valve, usually a pivoting blade inside a short duct section, fitted in the exhaust duct of a laboratory fume hood so that the volume of air drawn through the hood can be set, balanced against other hoods, or shut off during maintenance.

Controlling Airflow in the Exhaust Duct

A fume hood protects the user only when enough air is drawn in through its front opening to carry fumes up and away. Face velocity, the speed of that inflow, depends on the fan, the ductwork and the sash opening, and the damper is the adjustable element in that chain. Turning the blade across the duct raises the resistance and reduces the flow; opening it lets more air through.

Dampers matter most where several hoods share one exhaust fan. Without them, the hood nearest the fan draws most of the air and the furthest one too little. During commissioning a technician measures the face velocity at each hood, sets each duct damper for fume hood branches so that all of them fall within the range the laboratory has specified, and then locks the setting.

Fume-hood ductwork is commonly made from polypropylene or PVC, because the exhaust can carry acid vapours that corrode ordinary sheet steel, and the damper is normally chosen in a matching material and diameter. It is one component of the exhaust system; whether a hood performs safely must be confirmed by measuring the complete installation, never assumed from the damper alone.

Where a Damper Is Used

  • Balancing airflow between several fume hoods connected to one exhaust fan.
  • Setting face velocity during installation and at periodic re-testing of a hood.
  • Closing the exhaust branch of a hood taken out of service for maintenance.
  • Adjusting flow in snorkel or spot-extraction branches that share ductwork with hoods.

Specifications

Item Airflow damper for a fume hood exhaust duct
Principle Pivoting blade that varies resistance to airflow
Adjustment Typically set by hand and locked with a quadrant; motorised versions exist
Purpose Setting and balancing exhaust flow; isolating a hood branch for maintenance
Material, duct diameter and actuation of this item Confirm at enquiry

Care & Handling

  • Mark the commissioned blade position on the quadrant and keep the locking screw tight; an unnoticed change alters face velocity.
  • Never close the damper on a hood that is in use.
  • Include the damper in the hood’s periodic face-velocity check, and look for corrosion deposits that could stop the blade moving.
  • Leave adjustments to a competent ventilation technician, because re-balancing one hood changes the others.

Why Choose LabEquip

Laboratory furniture installers, ventilation contractors and institutions maintaining fume hoods order dampers when building or re-balancing an exhaust system. LabEquip lists the damper under General Lab Products, next to the Bracket for Spot Extractor used in similar exhaust work; give your duct diameter through the contact page.

Frequently Asked Questions

What does a damper do in a fume hood duct?

It adjusts how much air the exhaust draws through that hood. Partly closing the blade reduces the flow and opening it increases the flow, which is how the hood’s face velocity is set.

Does fitting a damper make a fume hood safe?

Not by itself. Safe containment depends on the whole system: fan, ducting, hood design, sash position and room air currents. Face velocity should be measured with an anemometer after installation and at regular intervals.

Why do fume hood ducts use plastic dampers?

Exhaust air can carry acid vapours that corrode steel. Polypropylene and PVC resist many of these vapours, so dampers for chemical fume exhaust are often made from the same plastic as the duct.

Can the damper be closed when the hood is not in use?

Only if the hood is clearly marked out of service and no chemicals remain inside it. In many systems the damper stays at its commissioned setting permanently and the hood is controlled by its sash instead.

What is the difference between manual and motorised dampers?

A manual damper is set by hand and locked. A motorised damper is moved by an actuator, often as part of a variable air volume system that changes the flow as the sash moves.

How is the right damper size chosen?

It must match the internal diameter of the exhaust duct at the point of fitting and the joining method used by the duct system, such as socket or flange joints.

Last Updated: September 2026