Quick Answer: The Vernier Caliper IME Type is a manual caliper listed under the IME type pattern name, with a main scale on the beam, a vernier on the sliding jaw, and jaws and a depth rod for outside, inside and depth readings. The IME type vernier caliper is used for measuring practicals in school and college labs.
About the IME Type Designation
The title identifies this caliper by its IME type designation, a pattern name used in laboratory catalogues rather than a technical term with one published definition. The listing image is not currently available, so the beam material, jaw length, range and least count of this pattern should be confirmed against a sample or data sheet; this page does not assume them.
Whatever the pattern, the reading method is the same. Suppose the vernier zero lies just past the 23 mm mark on the main scale and the seventh vernier line coincides with a main-scale line. With a least count of 0.1 mm, the observed reading is 23 + 7 × 0.1 = 23.7 mm. If the closed jaws had shown a zero error of +0.2 mm, the corrected reading would be 23.5 mm.
A practical that uses every feature of the instrument is the hollow cylinder exercise: measure the outside diameter with the lower jaws, the inside diameter with the upper jaws and the depth with the rod, then calculate wall thickness and internal volume. Where a metal body is specifically required, compare this item with the stainless steel vernier caliper; solid shapes for the density version of the exercise are available as equal-volume metal cylinders.
Specifications
| Designation | IME type (catalogue pattern name) |
| Instrument | Manual caliper with main and vernier scales |
| Measures | Outside and inside diameters, and depths |
| Reading | Main-scale reading plus coinciding vernier division × least count |
| Material, range and least count | Confirm at enquiry |
Applications
- Hollow cylinder practicals: outside and inside diameters, depth and internal volume
- Measuring spheres and cylinders for density determinations
- Checking test tubes and glass rods before fitting stoppers or clamps
- Recording readings with zero correction in practical notebooks for assessment
Care & Handling
- Before each practical session, close the jaws and write the zero error in the notebook, even when it is nil.
- Lock the slider before lifting the caliper out of a bore, so the reading is not disturbed.
- Keep the caliper in its case with the jaws slightly open, away from chemicals and moisture.
- Set aside any caliper whose slider rocks on the beam; it cannot give consistent readings.
Why Choose LabEquip
Schools and colleges replacing or matching existing caliper sets often order by the pattern name they already use, which is why this item is listed as IME type. LabEquip carries it in the General Lab Products range; mention the pattern, quantity and least count you expect on the contact page.
Frequently Asked Questions
What does IME type mean?
It is the pattern designation under which this caliper is listed. The title does not define it, so if your tender or syllabus names IME type specifically, share that document when you enquire so the supplied instrument can be matched to it.
How do I record a reading with zero correction?
Write down the main-scale reading, the coinciding vernier division and the least count, then the observed reading. Subtract a positive zero error, or add the size of a negative one, to get the corrected reading. Showing each step lets a teacher trace any mistake.
How is the wall thickness of a tube measured?
Measure the outside diameter with the large jaws and the inside diameter with the small jaws at the same end. Half the difference is the average wall thickness at that end; repeat at the other end to check for uneven walls.
Why should the slider be locked before reading?
Lifting the caliper out of a bore or groove can nudge the sliding jaw. Tightening the locking screw first holds the jaws where they touched the object, so the scale still shows the true size when you read it away from the workpiece.
How many readings should be taken of one object?
Take at least three, at different positions and orientations, for example across two perpendicular diameters of a cylinder. Averaging them reduces the effect of an object that is not perfectly round or uniform.
Can it measure depth in narrow holes?
The thin depth rod can reach into holes wider than the rod itself. Keep the end of the beam flat on the rim and the instrument upright; for very narrow or deep holes, a dedicated depth gauge is more suitable.
Last Updated: September 2026