Quick Answer: The Thermometer, Ground Joint (Cone Type) is a glass laboratory thermometer with a tapered ground-glass cone fused to its stem, so it plugs directly into the matching socket of a flask, adapter or distillation head. A ground joint thermometer makes a clean, sealed fit without rubber bungs or screw-cap thermometer adapters.
Why a Built-In Cone Helps
Jointed glassware relies on standard tapered joints: a ground cone on one piece fits a ground socket on the next. A plain thermometer needs a bored stopper or a screw-cap adapter to enter such a socket, and rubber or cork can swell, leak or contaminate when hot solvent vapour passes over it. Fusing a cone to the thermometer removes that weak link and fixes the bulb at a repeatable depth every time it is fitted.
In a simple distillation the bulb should sit just below the level of the side-arm, bathed in the vapour going to the condenser; that position gives the true boiling temperature. A cone thermometer whose length below the joint suits the still head holds that position automatically. In a multi-neck reaction flask, a longer version places the bulb in the liquid for reaction-temperature control.
The cone size must match the socket, and the length below the cone must suit the glassware; neither is given in the title. Joint sizes are commonly described by the widest diameter and the ground length in millimetres. Compatible glassware includes the distillation flask and the range of adapters.
Specifications
| Type | Glass laboratory thermometer with ground-glass cone |
| Joint | Male cone fused to the stem, fits a matching ground socket |
| Replaces | Bored stoppers and screw-cap thermometer adapters |
| Typical assemblies | Distillation heads, multi-neck flasks, reflux set-ups |
| Bulb position | Fixed by the stem length below the cone |
| Cone size, length below cone and range | Confirm at enquiry |
Applications
- Reading vapour temperature at the still head during simple and fractional distillation
- Watching reaction temperature in a multi-neck flask under reflux
- Solvent recovery set-ups where rubber bungs would swell or contaminate
- Vacuum work, where a greased ground joint seals better than a stopper
Care & Handling
- Apply a thin film of suitable joint grease, or use a PTFE sleeve, where the joint must not seize, especially with alkaline solutions.
- If a joint begins to stick, separate it while still warm, and never force a seized cone with a twist that loads the thermometer stem.
- Support the thermometer’s weight; do not rely on the joint alone in a tilted assembly.
- Wipe grease from the cone before washing so it does not spread onto the stem.
Why Choose LabEquip
Organic chemistry teaching labs, pharmacy colleges and research groups working with jointed glassware buy this thermometer for dependable distillation readings. LabEquip lists it in General Lab Products; send the joint size and the length you need via the contact page.
Frequently Asked Questions
Which joint size do I need?
The cone must match the socket it goes into. Read the size marking on your still head or flask socket and order the same size; mismatched joints leak or jam.
Where should the bulb be during distillation?
Just below the opening of the side-arm, so the vapour flowing to the condenser surrounds the bulb. Too high reads low, and too low can pick up the temperature of splashing liquid.
Do I need grease on the joint?
For most atmospheric distillations a light film of grease or a PTFE sleeve prevents sticking. For strong alkali or vacuum work, use grease or a sleeve suited to the conditions. Avoid excess grease, which contaminates the product.
How do I free a stuck ground joint thermometer?
Warm the outer socket gently with warm water so it expands slightly, then rotate carefully while supporting the stem close to the joint. Do not twist by the far end of the thermometer, which can snap.
Can the same thermometer be used for both vapour and liquid readings?
Only if the stem length below the cone places the bulb correctly for each. Distillation heads need a short immersed length; reaction flasks need a longer one to reach the liquid.
Is a cone thermometer suitable for vacuum distillation?
Yes, it seals more reliably than a stopper, provided the joint is greased or sleeved for vacuum and the thermometer is fitted before the system is evacuated.
Last Updated: September 2026