Quick Answer: The Thermometer, Enclosing Type is a laboratory glass thermometer in which the capillary tube and a separate scale strip are sealed together inside an outer glass envelope, so the graduations sit behind glass rather than being etched on the outside. An enclosing type thermometer keeps its scale clean and legible through repeated washing and chemical contact.
Scale Behind Glass
In a solid-stem thermometer the graduations are etched or printed on the outside of a thick capillary rod, where acids, alkaline detergents and abrasion slowly wear them away. The enclosed-scale design separates the two jobs. A fine capillary carries the liquid; next to it sits a white scale strip, commonly opal glass, printed with the graduations; and both are sealed into an outer protective tube. The markings cannot be rubbed off, and the white background gives strong contrast.
The outer tube adds glass around the capillary, so this design tends to respond a little more slowly than a slim solid-stem thermometer and will not pass through a narrow bore. It also needs a slightly larger stopper or holder. Check the scale strip occasionally for any shift against its reference, because a strip that has moved would misplace every reading.
The enclosed scale is a traditional choice for distillation, water baths and general lab use where readability matters. For a thermometer that fits a ground-glass socket directly, see the ground joint (cone type) thermometer; for a heavy solid stem, the laboratory thermometer.
Specifications
| Type | Enclosed-scale (enclosing type) glass thermometer |
| Construction | Capillary and separate scale strip sealed inside an outer glass tube |
| Scale background | White strip behind the capillary for contrast |
| Advantage | Markings protected from chemicals and abrasion |
| Trade-offs | Thicker body, slightly slower response |
| Range, length and immersion depth | Confirm at enquiry |
Applications
- Distillation and reflux set-ups where the scale must stay readable through many washes
- Water baths and thermostatic baths in chemistry and biology labs
- Teaching labs where etched solid-stem scales have worn from frequent cleaning
- General laboratory temperature measurement with high-contrast reading
Care & Handling
- Hold the enclosing type thermometer by the upper part of the outer tube, not by the bulb.
- Clean with detergent and water; avoid hydrofluoric acid and hot strong alkalis, which attack all glass.
- Stop using a thermometer whose scale strip has visibly moved.
- Store it in a rack or case so the outer tube does not chip.
Why Choose LabEquip
Chemistry teaching labs and quality-control rooms that wash thermometers daily often prefer enclosed scales. LabEquip lists this type in General Lab Products; send range and immersion requirements on the contact page.
Frequently Asked Questions
What is the difference between enclosing type and solid-stem thermometers?
A solid-stem thermometer has its scale marked on the outside of a thick capillary rod. An enclosing type has a thin capillary and a separate scale strip sealed inside an outer tube, which protects the markings.
Why is the scale on a white strip?
The white background makes the thin liquid thread stand out, so readings are easier and quicker to take, particularly with a coloured spirit filling or in poor light.
Is an enclosed-scale thermometer less accurate?
Not inherently. Its accuracy depends on calibration and correct immersion. The practical differences are a slower response and the need to confirm that the scale strip has not moved.
Can it be used in a distillation head?
Yes, when held in a suitable adapter or stopper with the bulb just below the side-arm opening, so it reads the vapour passing to the condenser. Make sure the outer diameter fits the adapter.
How can I tell whether the scale strip has moved?
Compare the strip’s position with any reference mark on the capillary or tube, and test a known point such as melting ice. A sudden constant offset in all readings also suggests the strip has shifted.
How should it be dried after washing?
Rinse with distilled water and let it drain upright in a rack. Do not dry it in an oven hotter than its scale range, since overheating can damage the capillary.
Last Updated: September 2026