Hematology Analyser, 18 Parameter Equipment Manufacturer,Supplier and Exporter in India

Hematology Analyser, 18 Parameter

Product Code : EL-LAI-10914
The Lab Equipment is a leading Hematology Analyser, 18 Parameter Manufacturer,suppliers and Exporter in India, Hematology Analyser, 18 Parameter Uruguay (Montevideo), Hematology Analyser, 18 Parameter Uzbekistan (Tashkent), Hematology Analyser, 18 Parameter Venezuela (Caracas), Hematology Analyser, 18 Parameter Vietnam (Hanoi), Hematology Analyser, 18 Parameter Yemen (Sana'a), Hematology Analyser, 18 Parameter Zambia (Lusaka), Zimbabwe (Harare), Eswatini (Mbabane) (Lobamba), Ethiopia (Addis Ababa), Fiji (Suva), Gabon (Libreville), Gambia (Banjul), Georgia (Tbilisi), Ghana (Accra), India (Delhi, Mumbai, Kolkatta, Chennai), Indonesia (Jakarta), Iraq (Baghdad), Ivory Coast (Yamoussoukro), Jamaica (Kingston), Jordan (Amman), Kazakhstan (Astana), Kenya (Nairobi), Kiribati (Tarawa), Kosovo (Pristina), Kuwait (Kuwait City), Kyrgyzstan (Bishkek), Laos (Vientiane), Latvia (Riga), Lebanon (Beirut), Lesotho (Maseru), Liberia (Monrovia), Libya (Tripoli), Lithuania (Vilnuis), Luxembourg (Luxembourg), Malawi (Lilongwe), Malaysia (Federal Territory of Kuala Lumpur), Maldives (Malle), Mali (Federal Territory of Kuala Lumpur), Malta (Male), Mauritania (Nouakchott), Mauritius (Port Louis), Mexico (Mexico City), Mongolia (Ulaanbaatar), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cambodia (Phnom Penh), Cameroon (Yaoundé), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb), Cuba (Havana), Cyprus (Nicosia), Czech Republic (Prague), Denmark (Copenhagen) ,Djibouti (Djibouti City), Dominican Republic (Santo Domingo), DR Congo (Kinshasa), Ecuador (Quito), Egypt (Cairo), El Salvador (San Salvador), Equatorial Guinea (Malabo), Eritrea (Asmara), Estonia (Tallinn)

Scope: Complete blood count (CBC), with 5-part differential, for routine hematology.
Platform: Bench-top, open, automated system.
Method: Flow-cytometry, colorimetry, electrical impedance.
Sample: Whole blood
Throughput: 50 to 100 samples per hour
Results reportable via external printer.
Power requirements: 220V/50Hz, with voltage surge protection.
High humidity, operating temperature 15C to 35C.
Quality control flags abnormal results, auto-calibration.
Connects to external PC via USB, can interface to LIS.
Casing is of corrosion-proof material.
Printed test results show sample ID, date and time, test results can be reported in graphs, histograms, scatter graphs.
Data management system built in for analysis and reporting, stores at least 100 patient data, including quality control and calibrators.
Red blood cell (RBC), white blood cell (WBC), hemoglobin (HGB), hematocrit (HCT), mean cell volume (MCV), Mean cell hemoglobin (MCH), red cell distribution (RDW-SD and RDW-CV), platelets (PLT), platelet distribution (PDW-SD and PDW-CV), mean platelet volume (MPV), WBC differential (neutrophils, lymphocytes, monocytes, eosinophils and basophils).


   