Neonatal incubator Automatic With Accessories Equipment Manufacturer,Supplier and Exporter in India

Neonatal incubator Automatic With Accessories

Product Code : EL-RAAE-11122
The Lab Equipment is a leading Neonatal incubator Automatic With Accessories Manufacturer,and suppliers in India, Neonatal incubator Automatic With Accessories Manufacturer,and suppliers in South Africa.Neonatal incubator Automatic With Accessories Suppliers in Mozambique,Neonatal incubator Automatic With Accessories in Supplier Kenya, Argentina (Buenos Aires), Australia (Canberra), Austria (Vienna), Bolivia (Sucre), Botswana (Gaborone), Brazil (Brasília), Brunei (Bandar Seri Begawan), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb) nda, Seychelles, Tanzania and Uganda.

Sturdy construction, mobile base with 4 anti-static swivel castors and 2 brakes.
Protective side/corner bumpers.
Double-wall neonatal incubator, mobile.
Automatic servo-control and manual control.
Mould and corrosion resistant frame.
Suitable for frequent and easy dismantling and cleaning.
Side rails, IV pole and instrument shelf.
Cabinet with 2 drawers, integrated in the base.
Side handles for easy moving.

Canopy:
Inclined front, with access door and 2 port holes.
2 rear port holes, double-wall.
radio-transparent.
4 (min) apertures for cables and tubing.
Silent incubator and door / port holes operation.
Dimensions 45 W x 80 L x 43 H cm (minimum guaranteed).

Mattress:
fixed mattress tray.
tilting ± 12 degrees.

Skin temperature sensor accuracy: ± 0.3 ºC
Air temperature setting: 25 – 37 ºC, override up to 39 ºC, with 0.1 ºC increments.
Temperature variability (fluctuation between set and real values): ± 0.5 ºC.
Temperature uniformity (at mattress level): < 0.8 ºC.
Skin temperature setting: 34 – 36 ºC, override up to 38 ºC, with 0.1 ºC increments.
Warm-up time: < 30 min
Air velocity over the bed: < 0.35 m/s
Automatic self-test and continuous system monitoring
Control panel and display, visualization of settings and measured parameters.
Audio-visual alarms for skin/air temperature, sensors, fan, heater, system functionality.
Air filter capacity at inlet 99 % particles: > 0.5 um
Power requirements: 110 – 220 V / 50 – 60 Hz
Power consumption: 600 – 750 W
Noise level inside the incubator: < 55 dB

Modes:
Servo-controlled, air temperature
Servo-controlled, skin temperature
Manual

   

Office Address

Works: C-956, Lane 2, Ashok Vihar, Phase-II,
Gurugram, Haryana 122001

[email protected]

+9170108-11519

Follow Us