Search

In Stock

X-ray Device

Appareil à rayons X « XR 4.0 X-ray expert unit », 35 kV Multi-functional Experimentation Chamber. Enables students to design and execute custom crystallographic setups, advancing from understanding wave-particle duality to creating original diffraction patterns for complex lattice structures.

Digital Goniometer Integration (Step-Resolution 0.1°) Facilitates the Analysis of atomic spacing via Bragg’s Law, allowing for high-resolution verification of the refractive index in various crystal orientations.

High-Stability 35 kV Anode Source Supports the Evaluation of characteristic K and L alpha radiation lines, enabling precise calculations for Moseley’s Law and atomic shell theory.

Integrated S-Bus High-Speed Data Port Permits real-time data acquisition and Application of computational physics models for 3D Computed Tomography (CT) reconstruction.

₹75,423.00

Quick Answer: This X-ray device is a teaching apparatus that produces X-rays in a tube inside a protective housing so that students can study their properties. It is used in university and college physics laboratories for Bragg diffraction on crystals, absorption measurements and simple radiographic imaging.

How the X-rays Are Produced

In an X-ray tube, electrons emitted from a heated cathode are accelerated through a high voltage and strike a metal anode. Most of their energy becomes heat, but a small fraction is emitted as X-rays in two forms. Bremsstrahlung, from electrons braking in the anode, gives a continuous spectrum whose shortest wavelength is set by the accelerating voltage. Characteristic lines, sharp peaks at wavelengths that depend on the anode metal, arise when incoming electrons knock out inner-shell electrons and the atom refills the vacancy.

Measuring how the short-wavelength limit moves as the tube voltage is changed tests the Duane-Hunt law, a route to Planck’s constant. Where tubes with different anodes are available, comparing their characteristic lines leads to Moseley’s law, which links line frequency to atomic number.

Experiments Inside the Housing

With a crystal mounted on a goniometer, X-rays reflect strongly only at angles meeting the Bragg condition, 2d sin θ = nλ. Rotating the crystal and the detector together records a spectrum in which the characteristic lines stand out; with a known crystal spacing the wavelengths follow, and with known wavelengths an unknown spacing can be found.

Placing foils of different thickness or different metals in the beam shows exponential absorption and the sharp absorption edges of elements. Where a fluorescent screen is fitted, objects in the beam cast shadows that reveal internal structure, the principle of medical radiography. Which goniometer, detector and screen options come with this device should be confirmed at enquiry.

Specifications

Product X-ray apparatus for physics teaching
Principle Electron impact on a metal anode producing continuous and characteristic X-rays
Main experiments Bragg diffraction, X-ray spectra, absorption, imaging
Operation Inside the device housing, under local radiation protection rules
Tube voltage, anode material, goniometer and detector Confirm at enquiry

Experiments Supported

  • Bragg reflection on single crystals and determination of lattice spacings
  • Recording continuous and characteristic X-ray spectra
  • Absorption of X-rays in metals of different thickness and atomic number
  • Simple radiographic imaging on a fluorescent screen, where fitted

Care & Handling

  • Operate the device only with its housing closed and all safety features working, and never attempt to bypass them
  • Follow the institution’s radiation protection rules, including any registration and supervising-person requirements
  • Allow the tube to cool as instructed between long runs
  • Keep crystals in their protective cases and handle them by the edges

Why Choose LabEquip

Universities and colleges buy an X-ray device when they want students to see diffraction and atomic spectra in the X-ray range, not just read about them. It works well in a laboratory that also runs the Franck-Hertz experiment on atomic energy levels; contact LabEquip to discuss the configuration and any local approval required.

Frequently Asked Questions

What experiments can a teaching X-ray device support?

Typical experiments include Bragg reflection on crystals, recording X-ray spectra, absorption in metals of different thickness, and simple imaging on a fluorescent screen, depending on the accessories fitted.

Why does the X-ray spectrum have both a continuous part and sharp lines?

The continuous part comes from electrons slowing down in the anode, giving radiation of all wavelengths above a limit. The sharp lines come from inner-shell transitions in the anode atoms and are characteristic of the anode metal.

What is the Bragg condition?

Reflection from crystal planes adds up strongly only when 2d sin θ = nλ, where d is the spacing of the planes and θ the glancing angle. It allows wavelengths or crystal spacings to be measured.

Is a teaching X-ray device safe to use with students?

Such devices are normally designed so that X-rays stay inside the housing during operation, with safety features that stop the tube when the housing is opened. They must still be used under the institution’s radiation protection rules, never with safety features bypassed.

How does the Duane-Hunt law give Planck’s constant?

The shortest wavelength in the continuous spectrum corresponds to an electron giving all its energy, eU, to one photon. Measuring that wavelength at several tube voltages and plotting it against 1/U gives a gradient of hc/e.

Do institutions need permission to use an X-ray device?

In many countries, yes: X-ray generators fall under radiation protection regulations that may require notification, registration or a named responsible person. Check the local requirements before installing the device.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top