Bernoulli and Venturi Experimental Platform

Plateforme expérimentale Bernoulli et Venturi supports the Application of stagnation pressure measurements to determine local flow velocity profiles within complex hydrodynamic modules.

High-Transmittance Acrylic Architecture Facilitates the visual Observation of laminar and turbulent transitions when utilized with dye injection, reinforcing evidentiary-grade laboratory reporting.

₹18,950.00

Quick Answer: The Bernoulli and Venturi experimental platform is a bench fluids apparatus on which water flows through a converging and diverging test section fitted with pressure tappings. It is used to verify Bernoulli’s equation at several sections and to calibrate the Venturi as a flow meter.

Two Experiments on One Rig

The first experiment checks Bernoulli’s equation. At a steady flow rate the pressure head is read at each tapping along the test section, the speed at each section is calculated from the measured flow rate and the local area, and the velocity head v²/2g is added to the pressure head. If the equation holds, the total head is almost the same at every section, falling only slightly downstream as friction takes its share.

The second experiment treats the section as a flow meter. Over a range of flow rates the head difference between inlet and throat is recorded, and the actual flow rate is measured by timing the collection of a known volume. The ratio of actual to theoretical flow is the discharge coefficient, C_d, which for a Venturi is usually a little below 1 because real water has friction and a non-uniform velocity across the pipe.

Getting Good Data

Take six to eight flow rates spread across the usable range and let the manometer levels settle after each change. Plotting the actual flow rate against the square root of the head difference should give a straight line through the origin; its gradient is the meter’s calibration constant, and scatter about the line shows the size of the reading errors.

Low flow rates deserve extra care. Because the head difference falls with the square of the flow, it shrinks to a few millimetres at the bottom of the range, where a reading error is a large fraction of the value. Longer timed collections help as well, keeping the error from starting and stopping the watch small. The water supply arrangement of the platform is confirmed at enquiry.

Applications

  • Verifying that total head stays nearly constant through the test section
  • Calibrating the Venturi and finding its discharge coefficient
  • Plotting actual flow rate against the square root of the head difference
  • Comparing measured and ideal pressure distributions along the section

Specifications

Product Bench platform for Bernoulli and Venturi experiments
Test section Converging and diverging passage with pressure tappings
Experiments Verification of Bernoulli’s equation; Venturi meter calibration
Results Total head at each section; discharge coefficient C_d
Water supply, pump, tank and manometer arrangement Confirm at enquiry

Care & Handling

  • Bleed the manometer tubes until no bubbles remain before each set of readings
  • Change the flow slowly and let the levels settle before recording
  • Keep any electrical supply and pump connections away from splashes
  • Drain fully after use and clean any tank regularly to prevent algae

Why Choose LabEquip

Engineering colleges and polytechnics running fluid mechanics practicals need a rig that produces real, analysable data on both Bernoulli’s equation and flow metering. For classroom demonstrations, the Venturi tube and the Bernoulli model cover the same ideas; contact LabEquip to confirm the configuration, or browse more physics lab equipment.

Frequently Asked Questions

What is the discharge coefficient of a Venturi meter?

The ratio of the actual flow rate, measured by timed collection, to the flow rate calculated from ideal Bernoulli theory. It is usually a little below 1 because real flow has friction and a non-uniform velocity profile.

Why plot flow rate against the square root of the head difference?

The Venturi equation makes flow rate proportional to the square root of the head difference, so this graph should be a straight line through the origin. Its gradient gives the meter’s calibration constant.

Why are low flow rates less accurate?

The head difference falls with the square of the flow, so at low flows it becomes only a few millimetres and reading errors are a large fraction of it.

How long should each timed collection be?

Long enough that the error in starting and stopping the watch is small compared with the total time. Collecting for 30 seconds or more keeps that timing error to around one percent.

How is this platform different from a simple Bernoulli demonstration?

A demonstration shows that pressure falls where flow speeds up. The platform is set up for measurement, with flow rates controlled and recorded, so students can calculate heads, test the equation and calibrate the meter.

Does the platform include its own pump and tank?

The water supply arrangement can be confirmed at enquiry. A self-contained platform recirculates water through a tank, while others run from a laboratory tap to a drain.