Search

In Stock

Venturi Tube

Tube de venturi, Integrated Differential Pressure Tappings Enables precise Evaluation of flow rates using manometric data, reinforcing evidentiary-grade laboratory reporting.

High-Transmittance Transparent Housing supports the visual Observation of fluid behavior and pressure gradients, essential for synthesizing theoretical physics with physical outcomes.

Uniform Smooth-Bore Interior Minimizes parasitic turbulence, allowing students to calculate head loss with high fidelity to theoretical Darcy-Weisbach models.

₹960.00

Quick Answer: A Venturi tube is a pipe section that narrows smoothly to a throat and then widens gradually again, with pressure tappings at the inlet and the throat. It is used to measure flow rate from the pressure difference between those two points and to demonstrate the Venturi effect.

From Pressure Difference to Flow Rate

Every second the same volume of fluid passes the inlet and the throat, so in the narrower throat it must travel faster. The extra kinetic energy is drawn from pressure energy, and the pressure at the throat falls. Combining the continuity equation with Bernoulli’s equation gives the flow rate as Q = A₂√(2Δp / (ρ(1 − (A₂/A₁)²))), where A₁ and A₂ are the inlet and throat areas and Δp is the measured pressure difference.

The equation hides a practical point. The pressure difference grows with the square of the flow rate, so doubling the flow quadruples the reading. A tube that gives a comfortable reading at high flow shows only a small difference at low flow, which is why real meters are chosen to suit the expected range.

Why the Exit Widens Slowly

The converging part of the tube is short, but the diverging part after the throat is long and gently tapered. That slow widening lets the fluid decelerate without breaking away from the wall, so most of the pressure lost at the throat is recovered downstream. Comparing the inlet and outlet pressures shows only a small permanent loss, much smaller than that caused by an orifice plate, which is simply a plate with a hole in it.

The low pressure at the throat is useful in its own right. It draws air or liquid in through a side opening in water aspirator pumps, paint and perfume sprayers and the carburettors of older petrol engines.

Applications

  • Measuring flow rate from the inlet-to-throat pressure difference
  • Showing that the pressure difference grows with the square of the flow rate
  • Comparing inlet and outlet pressures to show pressure recovery
  • Explaining aspirators, sprayers and carburettors

Specifications

Product Converging-diverging flow section with tappings
Principle Continuity and Bernoulli’s equation
Pressure readings At the inlet and at the throat, by manometer or gauge
Flow equation Q = A₂√(2Δp / (ρ(1 − (A₂/A₁)²)))
Working fluid, diameters and connections Confirm at enquiry

Care & Handling

  • Remove air from the tapping lines before taking readings
  • Keep the throat clean; deposits change its area and therefore the calculation
  • Protect transparent sections from knocks
  • Drain and dry the tube after use

Why Choose LabEquip

Teachers and lecturers use a Venturi tube to show the most practical application of Bernoulli’s equation, the measurement of flow. The same throat suction drives the laboratory filter pump, and the Bernoulli model covers the energy side of the topic; contact LabEquip for dimensions, or browse more physics lab equipment.

Frequently Asked Questions

Why is pressure lowest at the throat?

The same volume of fluid passes every section each second, so it must move fastest where the tube is narrowest. The extra kinetic energy comes from pressure energy, so the static pressure falls at the throat.

How does the pressure difference change with flow rate?

It rises with the square of the flow rate. Doubling the flow gives four times the pressure difference, so a single meter reads well over a limited span of flows.

Why does the tube widen so gradually after the throat?

A gentle diffuser lets the flow slow down without breaking away from the wall, so most of the pressure is recovered. An abrupt widening would create eddies and waste much more energy.

Where is the Venturi effect used?

In water aspirator pumps that pull a vacuum for filtration, in paint and perfume sprayers, in the carburettors of older engines and in flow meters on water and gas pipelines.

What is the difference between a Venturi tube and an orifice plate?

Both create a pressure drop that measures flow. An orifice plate is just a plate with a hole and is simple but wastes much of the pressure, while a Venturi tube recovers most of it.

What sizes are the inlet and throat?

The diameters and working fluid can be confirmed at enquiry. Both areas are needed for the flow calculation, so record them with the apparatus before the first practical.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart