Search

In Stock

Motor and Plate

Plaque terminale motrice features a highly detailed relief of the terminal bouton, representing acetylcholine-containing vesicles and the specialized subneural apparatus with secondary synaptic clefts for demonstrating electrochemical signaling.

Neuro-Muscular Interface Precision Illustrates the transition from the myelinated axon to the motor nerve ending, including the Schwann cell covering and the adjacent myofibril mitochondria, at a significantly magnified scale for tactile laboratory analysis.

₹9,800.00

Quick Answer: The Motor and Plate is a motor end plate model, an enlarged view of the neuromuscular junction where a motor nerve ending meets a skeletal muscle fibre and triggers it to contract; the title appears to be a misspelling of “motor end plate”. It is used in physiology, pharmacology and nursing teaching.

How the Neuromuscular Junction Works

Every skeletal muscle fibre is controlled by a branch of a motor neuron from the spinal cord or brainstem. Where the branch reaches the fibre, it spreads into a small cluster of terminals lying in shallow grooves on the fibre’s surface. That specialised patch of muscle membrane is the motor end plate, and the whole contact, nerve terminal plus end plate, is the neuromuscular junction.

When an impulse arrives, calcium channels in the nerve terminal open and synaptic vesicles release acetylcholine into the narrow gap between nerve and muscle, the synaptic cleft. The muscle membrane beneath is folded into junctional folds that carry many acetylcholine receptors. When acetylcholine binds, the receptors open, sodium ions flow in and the resulting end plate potential triggers an action potential across the muscle fibre, which then contracts. The enzyme acetylcholinesterase in the cleft breaks acetylcholine down within milliseconds, so each nerve impulse produces a single twitch.

Several drugs, toxins and diseases act here, which gives the model value beyond basic physiology: curare-type muscle relaxants block the receptors, botulinum toxin stops acetylcholine release, and in myasthenia gravis antibodies reduce the number of working receptors. For the same process between two neurons see The Synapse, and the Muscle Fiber Type model places the junction on a whole fibre.

Where It Is Used

  • Physiology lessons on nerve-to-muscle transmission
  • Pharmacology teaching on neuromuscular blocking drugs used in anaesthesia
  • Explaining myasthenia gravis and botulism in nursing and medical foundation courses
  • Comparing the neuromuscular junction with a synapse between neurons

Specifications

Model of Neuromuscular junction (motor end plate), enlarged
Title note “Motor and Plate” read as “motor end plate”
Structures typically shown Nerve terminal, synaptic vesicles, synaptic cleft, junctional folds
Topics Acetylcholine release, receptor binding, end plate potential

Care & Handling

  • Handle the motor end plate model by its base; fine structures such as the nerve fibre and terminal branches are fragile.
  • Dust with a soft brush and avoid wet cleaning around the joins between separately painted parts.
  • Store it covered, away from direct sunlight.

Why Choose LabEquip

Physiology and pharmacology tutors buy an end plate model because so many drugs and disorders act at this one junction, and learners need to see where. LabEquip lists it in biology lab products; use the contact page to ask about magnification.

Related Products

  • Muscle Fiber Type: A skeletal muscle fibre block that also shows a motor nerve ending, linking the junction to the myofibrils and T-tubules inside the fibre.
  • The Synapse: Shows a chemical synapse between two neurons, so students can compare nerve-to-nerve and nerve-to-muscle transmission.
  • Neuron Model: A whole neuron model that follows the impulse from dendrites along the myelinated axon to the terminals that end at this junction.
  • Human Model, Nerve Cell: An enlarged nerve cell, commonly a motor neuron, whose axon terminals form the motor end plate shown on this model.

Frequently Asked Questions

Is the Motor and Plate model the same as a motor end plate model?

Yes. The listing reads “Motor and Plate” as the motor end plate: an enlarged neuromuscular junction where a motor nerve ending meets a skeletal muscle fibre. Its specification lists the nerve terminal, synaptic vesicles, synaptic cleft and junctional folds, so it is a physiology model, not an electrical motor.

What is the difference between the motor end plate and the neuromuscular junction?

The motor end plate is the specialised patch of muscle membrane under the nerve ending, rich in acetylcholine receptors. The neuromuscular junction is the whole contact: the nerve terminal, the synaptic cleft and the end plate together. On the model, students can point to each part separately.

How does a nerve impulse make a skeletal muscle fibre contract?

The impulse opens calcium channels in the nerve terminal, and synaptic vesicles release acetylcholine into the cleft. Acetylcholine binds receptors on the end plate, sodium enters and the end plate potential triggers an action potential that spreads along the muscle fibre, leading to contraction.

Why is the muscle membrane folded at the end plate?

The junctional folds increase the area of muscle membrane facing the nerve terminal, so more acetylcholine receptors can sit opposite the release sites. This makes transmission reliable, so one nerve impulse dependably produces an end plate potential large enough to fire the muscle fibre.

What stops acetylcholine from making the muscle contract continuously?

The enzyme acetylcholinesterase in the synaptic cleft breaks acetylcholine down very quickly after release. Each impulse therefore causes one brief response. Drugs that block this enzyme prolong the action of acetylcholine, which is why the model is useful in pharmacology as well as physiology lessons.

Which diseases and drugs are explained with a neuromuscular junction model?

Curare-type muscle relaxants used in surgery block the receptors on the end plate; botulinum toxin stops acetylcholine release from the nerve terminal; and in myasthenia gravis antibodies reduce the number of working receptors, causing weakness that worsens with use. Each can be pointed to on the matching part of the model.

Last Updated: November 2026

Reviews

There are no reviews yet.

Write a review

Back to Top