Quick Answer: ELISA Plates are microplates, usually 96-well and made of clear polystyrene, whose well surface binds proteins so that antigens or antibodies can be fixed to it for enzyme-linked immunosorbent assays. ELISA plates are read in a microplate reader after a colour-forming enzyme reaction has developed in each well.
How an ELISA Plate Works
An ELISA begins by coating the wells: a solution of antigen or capture antibody is left in the plate, and the protein sticks to the polystyrene. Remaining binding sites are then blocked with an unrelated protein, samples are added, and a series of antibody and washing steps builds up an enzyme-labelled complex in wells where the target is present. A substrate such as TMB turns blue in proportion to the enzyme bound, the reaction is stopped with acid, and absorbance is read, commonly at 450 nm.
The plate surface decides how well proteins stick. Medium-binding surfaces suit larger, more hydrophobic proteins, while high-binding surfaces are treated to hold a wider range of antibodies and antigens more strongly. Plates come as solid 96-well plates or as frames holding removable 8- or 12-well strips, which let a lab run only as many wells as it has samples.
Flat-bottomed wells give an even light path for the reader. These plates are not interchangeable with tissue culture plates, which are treated for cell attachment, or with the Micro Test Plates, which are used for agglutination and dilution tests. Clear plates are used for colorimetric ELISA; white or black plates are used when the signal is luminescent or fluorescent.
Specifications
| Type | Microplate for ELISA and protein-binding assays |
| Typical material | Clear polystyrene |
| Usual layout | 96 flat-bottomed wells, solid or in strips |
| Readout | Absorbance in a microplate reader, commonly 450 nm for TMB |
Getting Consistent Results
- Keep unused strips sealed in their pouch, with desiccant if supplied, to protect the surface
- Cover plates with a sealing film during incubations to prevent evaporation
- Wash wells thoroughly and consistently, tapping the plate dry on paper towel between steps
- Avoid touching the well bottoms, since fingerprints affect absorbance readings
Applications
- Sandwich and indirect ELISA for detecting antibodies or antigens in serum
- Teaching immunology practicals on antigen-antibody binding
- Screening sera for antibody titre after immunisation
- Quantifying cytokines or hormones against a standard curve in research labs
Why Choose LabEquip
Immunology and microbiology departments, diagnostic training labs and research groups developing or running immunoassays are the main buyers. LabEquip supplies ELISA plates in Biology Lab Products; tell us the binding type and strip or solid format you need through our contact page.
Related Products
- Micro Test Plates: 96-well test plates for serial dilutions and agglutination tests, other microplate methods in immunology.
- Tissue Culture Plates: Sterile multi-well plates for growing cells, the plate to use when cells rather than proteins must attach.
- PCR Plate: A thin-walled polypropylene plate for PCR, the multi-well format for DNA rather than protein assays.
- Deep Multi Well Plates: Deep-well plates with a standard footprint for preparing sample dilutions before loading the ELISA plate.
Frequently Asked Questions
What are ELISA plates made of?
ELISA plates are usually made of clear polystyrene, whose surface binds proteins. Antigen or capture antibody sticks to the wells during coating, and the clear plastic lets the coloured product of the enzyme reaction be measured by absorbance in a microplate reader.
What is the difference between medium-binding and high-binding ELISA plates?
Medium-binding surfaces suit large proteins such as antibodies. High-binding surfaces are treated to hold more protein, including smaller or less water-repelling molecules. A higher-binding surface can also raise background, so the blocking step matters more.
At what wavelength is an ELISA plate read?
It depends on the substrate. TMB, the most common, turns blue as it reacts and yellow once the reaction is stopped with acid, and is then read at 450 nm. Other substrates give other colours and are read at their own wavelengths.
Why are ELISA plate wells blocked after coating?
After coating, parts of the plastic surface can still bind protein. Blocking with an unrelated protein such as bovine serum albumin or milk protein fills these sites, so antibodies added later do not stick at random and raise the background signal.
Can ELISA plates be washed and reused?
No. After a run the wells carry bound proteins that washing does not remove reliably, and the surface no longer binds evenly. The washes within one assay are a different thing: they remove unbound material between steps on a plate that is then discarded.
What is the difference between an ELISA plate and a tissue culture plate?
An ELISA plate surface is made to bind proteins for assays, and sterility is usually not needed. A tissue culture plate is sterile, lidded and surface-treated so living cells attach and grow. The two surfaces are made for different jobs and are not interchangeable.