In Stock

Stage Micrometer

High-Tolerance Photo-Etched Scale: Features a vacuum-deposited chrome scale on a premium optical glass substrate, offering a 1mm total length divided into 100 equal parts (0.01mm increments) for sub-micron resolution.

Standardized Form Factor: Engineered in a universal 75mm x 25mm slide format with an integrated cover slip to protect the graduation markings from mechanical abrasion and environmental oxidation.

₹540.00

Quick Answer: The Stage Micrometer is a glass microscope slide carrying a very finely ruled scale of known length, placed on the stage to calibrate an eyepiece graticule. A stage micrometer is the reference that turns graticule divisions into real distances in micrometres.

The Reference Scale for Microscope Measurement

This slide is a calibration standard for the individual microscope rather than a tool for measuring specimens. Its ruling lies where a specimen would lie, so it is magnified by exactly the same optics. A common ruling divides 1 mm into 100 parts, making each small division 0.01 mm, or 10 micrometres, but rulings vary, so always read the value marked on the slide you use.

Calibration takes a few minutes. Focus on the ruled scale with the lowest-power objective, turn the eyepiece so the eyepiece graticule scale lies alongside it, and move the slide until a line on each scale coincides. Find a second point further along where lines coincide again and count the divisions on both scales between the two points. As a worked example, if 20 stage divisions of 10 micrometres span 50 eyepiece divisions, one eyepiece division equals 200 ÷ 50 = 4 micrometres with that objective.

Because each microscope needs calibrating only once for every objective and eyepiece combination, many departments keep a single calibration slide per room and record the results on a card that stays with each instrument.

Applications

  • Calibrating an eyepiece graticule for each objective before cell-measurement practicals
  • Setting the scale in eyepiece camera or digital microscope software
  • Checking magnification figures in student investigations
  • Teaching the idea of calibration against a known standard

Specifications

Item Calibration slide for microscope measurement
Form Glass slide carrying a finely ruled scale
Typical ruling on such slides 1 mm divided into 100 divisions of 10 micrometres
Used with Eyepiece graticules and camera measuring software
Ruling of the slide supplied Confirm at enquiry

Care & Handling

  • Handle the stage micrometer by its edges and keep it in its protective case; a scratch across the ruling ruins it.
  • Lower objectives towards the slide only while watching from the side, especially at high power.
  • Clean it with a blower and a lens tissue lightly moistened with lens cleaner, wiping along the lines rather than across them.
  • Store it flat in a drawer, away from heavy objects that could crack it.

Why Choose LabEquip

Colleges and schools teaching quantitative microscopy need at least one calibration slide so that their measurements have a true scale. It is listed in the Microscope & Optics range together with graticules; say how many rooms or microscopes you calibrate on the contact page.

Frequently Asked Questions

Can I measure specimens directly with a stage micrometer?

In principle a specimen could be placed beside the scale, but the specimen and the ruling cannot usually be in focus together on one slide. The slide is used to calibrate the eyepiece graticule, which then measures the specimen on its own slide.

How often should I calibrate?

Once for each objective on each microscope, and again whenever the eyepiece, graticule or objectives are changed. Record the value of one eyepiece division for every objective on a card kept with the microscope.

Why is the ruling hard to see at high power?

At high power only a few divisions fill the field and the lines are thin. Close the condenser diaphragm a little to raise contrast and focus slowly; find and centre a line on low power first, then switch up.

What does the scale look like?

Usually a straight line of fine divisions, with longer lines every fifth or tenth division for easier counting. Some slides carry a grid or a cross scale instead, and the length of each division is normally marked on the slide.

Do I need a separate calibration for an eyepiece camera?

Yes. A camera records a different field from the one seen through the eyepiece, so photograph the ruling at each objective with the camera and use those images to set the software’s scale.

Why is the calibration slide so fragile?

The ruling is very fine and usually protected only by a cover glass or a thin layer, so a knock from an objective or grit on a cloth can damage it. Keep it in its case and bring objectives down only while watching from the side.