Weight Set, 1mg-500g, Class E2

Austenitic Non-Magnetic Stainless Steel: Forged from high-density, corrosion-resistant alloy with a magnetic susceptibility (χ) below 0.005, eliminating electromagnetic interference during sensitive mass determination in pharmaceutical and forensic environments.

Monoblock Mirror-Polished Surface: Features a specialized mirror finish with surface roughness (Ra) below 0.1 µm, preventing microscopic particulate accumulation and ensuring mass stability through rigorous analytical duty cycles.

₹1,698.00

Quick Answer: The Weight Set, 1mg-500g, Class E2 is a set of reference weights from 1 mg to 500 g, titled in accuracy class E2, spanning the range of analytical balances and smaller precision balances. An E2 test weight set of this range lets one laboratory check both kinds of balance with a single set of high-class weights.

One Set for Two Kinds of Balance

Many laboratories run an analytical balance for small samples alongside a precision balance with a larger capacity for routine weighing. A range reaching 500 g covers the span tests of both, while the milligram pieces at the other end allow checks at the smallest loads. That reduces the number of sets to maintain and recalibrate, though it means the one set must be handled with particular care, because damage to a single piece affects checks on both balances.

Air Buoyancy and Conventional Mass

Everything on a balance pan is pushed up slightly by the air it displaces, and the push depends on volume. A large, low-density object displaces more air than a compact steel weight of the same mass, so it reads slightly light against that weight. To make weighings comparable, weights are specified by their conventional mass: the mass of a reference weight of a standard density that would balance them in air of a standard density.

For most samples buoyancy is ignored. At the level where E2 weights are used, however, it can matter: when weights of a different material are calibrated, or when the air density in the laboratory differs noticeably from the standard, a correction is calculated. Students meeting this for the first time see Archimedes’ principle at work in the air around them.

Temperature, Storage and Recalibration

Temperature differences cause the largest everyday errors with high-class weights. A weight warmer or cooler than the air sets up convection around the pan, so weights are kept in the balance room, ideally in the same cabinet, and given time to settle before use. The case protects them from dust and knocks and should be closed whenever a piece is not in use. Recalibration at regular intervals, and after any accident, keeps the stated values trustworthy.

Applications

  • Calibration and checks of analytical balances and precision balances up to 500 g
  • Calibrating lower-class weights by comparison
  • Air-buoyancy and conventional-mass exercises in metrology courses
  • Balance qualification in pharmaceutical, food and research laboratories

Specifications

Nominal range 1 mg to 500 g, as titled
Accuracy class E2, as titled
Coverage Analytical and precision balances within the range
Handling Gloves and forceps; no bare-hand contact
Piece list, material, case and calibration report Confirm at enquiry

Care & Handling

  • Keep the E2 test weight set in the balance room so it stays at the same temperature as the balance.
  • Handle milligram pieces with forceps and larger pieces with gloves or a lifter.
  • Close the case after each piece is used and store it away from vibration, sunlight and heat sources.
  • Keep the calibration records with the set and plan recalibration before they fall due.

Why Choose LabEquip

Laboratories with both analytical and precision balances choose a 1 mg to 500 g E2 set to cover them with one reference. LabEquip lists it in its Physics Equipments range; the Class E2 weight set, 1 g to 2 kg is the option for larger capacities. Share your balance capacities and documentation needs via the contact page.

Frequently Asked Questions

What is conventional mass?

It is the mass value used for weights in practice: the mass of a reference weight of standard density that would balance the weight in air of standard density. It lets weights of different materials be compared without buoyancy corrections in normal conditions.

Why does air buoyancy matter for E2 weights?

Air pushes up on every object in proportion to its volume. For high-class weights, and when weights or samples of different density are compared, that small upward force can be comparable to the permissible error, so it has to be considered.

Can one set really serve an analytical and a precision balance?

Yes, if both balances’ test loads lie within 1 mg to 500 g and class E2 is appropriate for each. The set then covers span, linearity and low-load checks for both instruments.

Where should high-class weights be stored?

In their closed case, in the same room as the balances, away from heat, sunlight, vibration and chemical fumes. Keeping them at room temperature means they are ready for use without long acclimatisation.

What happens if a weight is dropped?

Its mass may have changed through a chip, dent or contamination. Mark it, stop using it for checks and have it recalibrated before it is trusted again.

Why use E2 rather than F1 for this range?

E2 weights have permissible errors about one third of F1 values, which matters when checking balances with fine readability or when the set is used to calibrate F1 weights. For routine checks of coarser balances, F1 may be sufficient.

Last Updated: October 2026