Analytical Balance 220g/0.1mg

Electromagnetic Force Restoration (EMFR) Sensor: Utilizing a high-performance monobloc transducer, this system delivers ultra-fast stabilization times and exceptional linearity for 0.1mg resolution, effectively minimizing sensitivity drift across the full 220g capacity range.

Integrated All-Glass Draft Shield: Designed with a spacious anti-static weighing chamber and high-transparency sliding doors to mitigate air turbulence and environmental interference, ensuring high repeatability during micro-analytical procedures and sensitive mass determinations.

₹5,560.00

Quick Answer: The Analytical Balance 220g/0.1mg is an electronic laboratory balance that weighs loads up to 220 g and displays mass to 0.1 mg, the fourth decimal place of a gram. This analytical balance is used for quantitative work such as weighing primary standards, samples for gravimetric analysis and small amounts of reagents.

What 0.1 mg Readability Means

Readability is the smallest change in mass the display can show. At 0.1 mg (0.0001 g) over a 220 g range, the balance has more than two million display steps. That sensitivity is what quantitative chemistry relies on: a 0.2 g portion of a primary standard weighed to 0.1 mg carries a rounding error of well under one part in a thousand.

Readability is not the same as accuracy. What a user actually achieves depends on repeatability, on how well the balance is calibrated and levelled, and on the room. For that reason a balance of this class is normally used with a glass draft shield closed around the pan, on a solid bench away from doors, air-conditioning outlets and direct sunlight.

Weighing by Difference

Many analytical weighings are done by difference rather than directly onto paper. Weigh a capped weighing bottle containing the solid, tip the required portion into the flask, and weigh the bottle again. The loss in mass is the amount transferred, and nothing left behind on paper or a spatula is wrongly counted. The method suits solids that pick up moisture from the air and makes full use of a 0.1 mg display, because both readings are taken on the same container.

Specifications

Type Electronic laboratory balance, analytical class
Maximum capacity 220 g
Readability 0.1 mg (0.0001 g)
Typical use Quantitative weighing of samples, standards and precipitates
Calibration method, pan size and power supply Confirm at enquiry

Applications

  • Weighing primary standards such as potassium hydrogen phthalate or anhydrous sodium carbonate for titrations
  • Gravimetric analysis, including weighing crucibles and precipitates to constant mass
  • Preparing standard solutions for making up in a volumetric flask
  • Weighing small samples of drugs, excipients or reference materials in pharmacy and research laboratories

Care & Handling

  • Level the balance whenever it is moved, and let it warm up after switching on before calibrating.
  • Never put chemicals directly on the pan; use a weighing boat, bottle or paper, and brush away spills at once.
  • Let hot or cold containers reach room temperature first; a warm object sets up air currents that make it read light.
  • Close the draft shield doors before taking a reading and keep the bench free of vibration.

Why Choose LabEquip

Balances of this readability are bought by chemistry, pharmacy and quality-control laboratories that weigh standards and samples every day. LabEquip lists this 220 g model in its physics and measurement equipment category. Discuss calibration weights and installation through the contact page.

Frequently Asked Questions

What is the difference between an analytical balance and a precision balance?

An analytical balance reads to 0.1 mg or finer and is used with a draft shield for quantitative work. A precision, or top-loading, balance usually reads to 1 mg, 10 mg or 0.1 g, carries more load on a larger pan, and is used for general weighing where the fourth decimal place is not needed.

Why does the reading drift when I weigh a warm crucible?

A warm object heats the air around it, and the rising air pushes up on the pan, so the reading is low and then creeps upward as the crucible cools. Cool crucibles to room temperature in a desiccator before weighing.

How often should the balance be calibrated?

Calibrate after installation, after moving it and whenever the room temperature changes noticeably, and check it routinely with a known test weight. Many laboratories do a quick daily check and keep a log of the results.

Why does a plastic container give an unstable reading?

Dry plastic containers and powders can carry static charge, which pulls on the pan and the draft shield and makes the reading wander. Use glass or metal containers where possible, or neutralise the charge with an anti-static device.

What is weighing by difference?

Weigh a closed container with the sample, transfer some of the sample, and weigh the container again. The difference is the mass transferred. It avoids errors from material left on weighing paper and suits substances that absorb moisture.

Why should weighed items not be handled with bare fingers?

Fingerprints add oils and moisture that can amount to tenths of a milligram, and the warmth of a hand creates air currents. Use tongs, forceps or gloves for crucibles and weighing bottles that are being taken to constant mass.

Last Updated: October 2026