Search

In Stock

Receiver Adapters, Plain Bend, Short

Precision-Ground 105° Geometry: Features a short-radius bend with a fire-polished drip tip, specifically engineered to minimize liquid holdup and ensure laminar flow in high-throughput vertical distillation setups.

Standardized Interchangeable Joints: Manufactured with CNC-ground 1:10 taper interfaces, achieving a high-vacuum matte finish that guarantees a hermetic, leak-proof seal across standardized modular glass assemblies.

₹325.00

Quick Answer: A short plain bend receiver adapter is a compact curved glass fitting with no side tube that links a condenser outlet to a receiving vessel close below it. The short delivery end keeps the distillation set low and suits small receivers and small-scale work.

Keeping the Set Compact

Height is often the limiting factor on a distillation bench. The boiling flask sits above its heat source, the still head and thermometer rise above that, and the condenser slopes down to a receiver that needs space beneath the adapter. A short bend brings the receiver up close to the end of the condenser, so the set fits under a fume cupboard sash or on a crowded retort stand, and small receivers are not left dangling beneath a long limb.

With less glass beyond the bend there is also less surface on which distillate can cling, which helps in semi-micro distillations where every drop counts. The trade-off is that the tip sits near the top of the receiver, so volatile products are better collected in a cooled flask, and the short limb cannot reach into a trapping solution; the long pattern exists for that.

The title gives neither the joint size nor the bend angle, and like every plain bend this adapter has no vent of its own.

Care & Handling

  • Use grease sparingly or not at all; in small-scale work any grease that reaches the product can show up as an impurity.
  • Check that the drip point is still inside the receiver neck after every change to the condenser angle.
  • Rinse the adapter with a little of the pure solvent into the receiver before washing, to recover traces of product.

Applications

  • Small-scale and semi-micro distillations in college organic chemistry
  • Distillation sets that must fit under a low fume cupboard sash
  • Delivering into small round-bottomed or pear-shaped receivers held close to the condenser
  • Compact set-ups where transfer losses must be kept low

Specifications

Type Receiver adapter, plain bend, short pattern
Delivery limb Shorter than the standard bend
Side tube or vent None
Suited to Compact sets and small receivers

Why Choose LabEquip

Colleges and research groups running small-scale preparations usually order short bends with matching small receivers. LabEquip lists them among its chemistry lab equipment and supplies the bent vacuum receiver adapter for the same sets when work moves to reduced pressure; ask for joint sizes through the contact page.

Related Products

Frequently Asked Questions

When is a short plain bend preferred over the standard bend?

When height is limited, for example under a fume cupboard sash or on a crowded retort stand. The short delivery brings the receiver up close to the end of the condenser, so the whole set stays low and small receivers are not left hanging under a long limb.

Can a short plain bend be used for small-scale distillation?

Yes. With less glass beyond the bend there is less surface for distillate to cling to, which helps in semi-micro distillations where every drop counts. Pair it with a small receiving flask clamped close beneath.

Does a short receiver bend increase evaporation losses?

The tip sits near the top of the receiver, so volatile products have a shorter path to escape from the neck. Standing the receiver in an ice bath reduces the loss. For very volatile products, the long bend delivers lower into the cooled flask.

Does the short plain bend have a side tube?

No. Like the standard and long plain bends, it has only the condenser joint and the delivery end. It is used with an open receiver so the set vents around the tip, never sealed into a jointed flask while heating.

How is the receiver held under such a short bend?

Clamp the receiver by its neck on the retort stand, or set it on a small adjustable stand or block, so its mouth sits just below the delivery tip. Leave a small gap around the tip so air can escape.

Is a short plain bend the same as a short-path distillation head?

No. A short-path head combines the still head, a very short condenser and the delivery in one piece for vacuum work on small samples. The short plain bend is only the receiver fitting and is used after a separate condenser.

Last Updated: November 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)