Quick Answer: The e/m by Thomson’s Method (Bar Magnet Method) apparatus measures the specific charge of the electron by deflecting a cathode ray beam with an electric field between plates and cancelling that deflection with the magnetic field of a pair of bar magnets. Thomson’s method with bar magnets is a common undergraduate practical because the magnetic field is easy to set up and measure.
Crossed Fields on an Electron Beam
J. J. Thomson showed in 1897 that cathode rays are streams of particles with a fixed ratio of charge to mass. The teaching version uses a small cathode ray tube whose beam passes between a pair of deflection plates before striking a fluorescent screen. A voltage V across plates separated by a distance d produces an electric field E = V/d that pushes the spot up or down. Two bar magnets, placed symmetrically on either side of the tube on a line at right angles to it, produce a magnetic field B across the beam.
When the magnets are positioned so that the spot returns to its undeflected position, the electric force eE and the magnetic force evB on each electron are equal and opposite, so the electrons’ speed is v = E/B. With the magnetic field removed, the deflection y caused by the electric field alone is measured on the screen. Using the plate length l and the distance L from the plates to the screen, the result is e/m = yV/(B²dlL).
Measuring the Field of the Bar Magnets
What gives the method its name is how B is found. After the balance has been achieved, the cathode ray tube is replaced by a deflection magnetometer (a compass box) placed exactly where the beam was, with the magnets left at the same distances. The magnetometer needle settles at an angle θ where the magnets’ field and the Earth’s horizontal field combine, so B = BH tan θ. The local value of BH is taken from tables or measured separately. Setting the tube along the magnetic meridian means the Earth’s horizontal field lies along the beam, where it exerts no sideways force on the electrons.
Specifications
| Quantity determined | Specific charge e/m of the electron |
| Method | Thomson’s crossed-field method, magnetic field from a pair of bar magnets |
| Main parts (typical) | Cathode ray tube with deflection plates, power supply, pair of bar magnets, deflection magnetometer |
| Level | Undergraduate physics laboratories |
| Supplied parts, tube and power supply | Confirm at enquiry |
Practical Work
- Determining e/m of the electron by Thomson’s balancing method
- Showing that crossed electric and magnetic fields select particles of one speed, the principle of a velocity selector
- Using a deflection magnetometer and the tangent law to measure a magnetic field
- Comparing the result with the magnetic focusing method and discussing the sources of error in each
Care & Handling
- The cathode ray tube runs at a high voltage; set up and change connections only with the supply switched off.
- Keep spare magnets, steel stands and tools away from the tube and magnetometer while readings are taken.
- Store the bar magnets in pairs with keepers so their field, and therefore the calibration, does not weaken over time.
- Turn the spot brightness down to the lowest comfortable level to avoid burning the screen phosphor.
Why Choose LabEquip
College physics laboratories buy this set-up because it combines electron-beam physics with the magnetometer techniques students already know. LabEquip lists it in its physics lab equipment range, alongside the other e/m methods. For the tube, power supply and parts supplied, contact us through the LabEquip contact page.
Frequently Asked Questions
Why is it called the bar magnet method?
Because the magnetic field across the electron beam comes from a pair of bar magnets rather than from coils. Their field at the tube is then measured with a deflection magnetometer using the tangent law.
How is the magnetic field at the tube measured?
The tube is replaced by a deflection magnetometer at the same position, with the magnets unmoved. The needle’s deflection angle gives the field as the Earth’s horizontal field multiplied by the tangent of that angle.
What does balancing the two deflections show?
When the spot is back in its original position, the electric and magnetic forces on each electron are equal. The electrons’ speed then equals the electric field divided by the magnetic field, and this speed is used in the e/m calculation.
Which formula is used to calculate e/m?
e/m equals y times V, divided by B squared times d times l times L. Here y is the deflection due to the electric field alone, V the plate voltage, d the plate separation, l the plate length and L the distance from the plates to the screen.
Why should the tube lie along the magnetic meridian?
Then the Earth’s horizontal magnetic field points along the electron beam. A field parallel to the motion of the electrons exerts no force on them, so the Earth’s field does not add an unwanted deflection.
How does this differ from Thomson’s original experiment?
Thomson used an evacuated glass discharge tube with plates and a magnetic field across it. The teaching apparatus keeps the same crossed-field principle but uses a ready-made cathode ray tube and permanent magnets measured with a magnetometer.