Viscometer Searle’s Pattern

Precision-Machined Concentric Geometry: Features a high-tolerance inner rotating cylinder supported by a friction-reducing ball bearing assembly designed to measure torque through a falling-weight pulley system.

Stable Laboratory Configuration: Constructed on a heavy-duty, anti-corrosive tripod base with an integrated graduated pulley and adjustable leveling feet to ensure strict axial alignment during high-sensitivity fluid testing.

₹875.00

Quick Answer: The Viscometer Searle’s Pattern is a rotating-cylinder viscometer for thick liquids: an inner cylinder turns inside a fixed outer cylinder filled with the test liquid, driven by weights on a cord wound round a drum. From the steady rate of rotation under a known driving load, the coefficient of viscosity is calculated.

How Searle’s Rotating-Cylinder Method Works

In a Searle’s pattern viscometer the liquid fills the narrow annular gap between two coaxial cylinders. The outer vessel stays still while the inner cylinder is made to turn by a cord that runs from a drum on its spindle, over pulleys, to a weight hanger. When the weights are released the cylinder speeds up briefly, then settles to a steady angular velocity at which the couple from the falling load is exactly balanced by the viscous drag of the sheared liquid layers.

For two long coaxial cylinders the viscous couple is G = 4πηlω a²b²/(b² − a²), where a is the radius of the inner cylinder, b the inner radius of the outer vessel, l the immersed length and ω the angular velocity. The driving couple is Mgr, with r the radius of the drum, so η follows once ω is found by timing a counted number of revolutions. The flat bottom of the inner cylinder adds drag that this formula ignores; repeating the run at two depths of immersion and working with the difference removes that end effect.

Searle’s method suits liquids far too viscous for capillary-flow methods, such as glycerine and heavy oils. It complements the falling-ball Stokes method apparatus, which uses the same kind of liquid but times a sinking sphere instead of a rotation, and the oscillating-disc viscosity apparatus, which works from damped swings. The cylinder radii, drum size and pulley arrangement are not given in the listing title; they enter the calculation and are measured on the instrument itself.

Specifications

Instrument Searle’s pattern rotating-cylinder viscometer
Principle Viscous drag between coaxial cylinders balanced against a known couple
Drive Falling weights on a cord wound round a drum
Measured quantity Steady angular velocity, from timed revolutions
Suitable liquids Highly viscous liquids such as glycerine and castor oil
Cylinder radii, drum radius and weights supplied Confirm at enquiry

Experiments

  • Determining the coefficient of viscosity of glycerine or castor oil at room temperature
  • Showing that the steady angular velocity rises in proportion to the driving load for a Newtonian liquid
  • Eliminating the end correction by comparing runs at two immersion depths
  • Comparing the viscosity of the same oil on a cool and a warm day to show its strong temperature dependence

Care & Handling

  • Fill the outer cylinder slowly and let air bubbles rise out before a run, since trapped bubbles change the drag.
  • Keep the spindle bearings clean and lightly lubricated so that friction stays small compared with the viscous couple.
  • Wind the cord evenly on the drum and stop the weights before they strike the floor while the cylinder is still turning.
  • Note the liquid temperature with every set of readings, because viscosity falls quickly as temperature rises.
  • Drain and clean both cylinders after use; glycerine left standing absorbs moisture from the air and becomes thinner.

Why Choose LabEquip

Undergraduate and polytechnic physics laboratories choose this viscometer for the viscosity of very thick liquids, where the practical trains students in steady-state timing and end corrections. It sits in our Physics Equipments range; to confirm the drive weights and cylinder dimensions supplied, contact LabEquip.

Frequently Asked Questions

Which cylinder rotates in Searle’s viscometer?

The inner cylinder rotates and the outer vessel holding the liquid stays fixed. The falling weights act through a cord on a drum fixed to the inner cylinder’s spindle, so the liquid in the gap is sheared between a moving and a stationary surface.

Why must readings be taken only after the speed becomes steady?

The formula assumes the driving couple is exactly balanced by viscous drag. While the cylinder is still speeding up, part of the couple goes into increasing its rotation, so timing too early gives a falsely high viscosity. Wait until successive revolutions take equal times.

How is the end correction removed?

The flat bottom of the inner cylinder adds drag that the coaxial formula leaves out. Take readings at two immersion depths under the same load; the end effect is the same in both runs, so it cancels when the change in immersed length and the matching change in rotation rate are used.

Which liquids can be tested with this viscometer?

It is intended for liquids of high viscosity, such as glycerine, castor oil and thick lubricating oils. Thin liquids like water offer so little drag that the cylinder spins too fast to time and bearing friction becomes the main resistance.

How does bearing friction affect the result?

Friction at the spindle adds to the viscous drag and makes the viscosity appear larger. A common correction is to find the smallest load that keeps the empty cylinder turning steadily and subtract it from each driving load.

How is Searle’s method different from the falling-ball method?

Searle’s viscometer shears the liquid steadily between two cylinders and measures a rotation rate under a known couple. The falling-ball method times a sphere sinking through the liquid at terminal velocity and applies Stokes’ law. Both suit thick liquids, so they are often used together to cross-check a value.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)